4 resultados para Open-air schools

em Dalarna University College Electronic Archive


Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this thesis, one of the current control algorithms for the R744 cycle, which tries tooptimize the performance of the system by two SISO control loops, is compared to acost-effective system with just one actuator. The operation of a key component of thissystem, a two stage orifice expansion valve is examined in a range of typical climateconditions. One alternative control loop for this system, which has been proposed byBehr group, is also scrutinized.The simulation results affirm the preference of using two control-loops instead of oneloop, but refute advantages of the Behr alternate control approach against one-loopcontrol. As far as the economic considerations of the A/C unit are concerned, usinga two-stage orifice expansion valve is desired by the automotive industry, thus basedon the experiment results, an improved logic for control of this system is proposed.In the second part, it is investigated whether the one-actuator control approach isapplicable to a system consisting of two parallel evaporators to allow passengers tocontrol different climate zones. The simulation results show that in the case of usinga two-stage orifice valve for the front evaporator and a fixed expansion valve forthe rear one, a proper distribution of the cooling power between the front and rearcompartment is possible for a broad range of climate conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hybrid Photovoltaic Thermal (PVT) collectors are an emerging technology that combines PV and solar thermal systems in a single solar collector producing heat and electricity simultaneously. The focus of this thesis work is to evaluate the performance of unglazed open loop PVT air system integrated on a garage roof in Borlänge. As it is thought to have a significant potential for preheating ventilation of the building and improving the PV modules electrical efficiency. The performance evaluation is important to optimize the cooling strategy of the collector in order to enhance its electrical efficiency and maximize the production of thermal energy. The evaluation process involves monitoring the electrical and thermal energies for a certain period of time and investigating the cooling effect on the performance through controlling the air mass flow provided by a variable speed fan connected to the collector by an air distribution duct. The distribution duct transfers the heated outlet air from the collector to inside the building. The PVT air collector consists of 34 Solibro CIGS type PV modules (115 Wp for each module) which are roof integrated and have replaced the traditional roof material. The collector is oriented toward the south-west with a tilt of 29 ᵒ. The collector consists of 17 parallel air ducts formed between the PV modules and the insulated roof surface. Each air duct has a depth of 0.05 m, length of 2.38 m and width of 2.38 m. The air ducts are connected to each other through holes. The monitoring system is based on using T-type thermocouples to measure the relevant temperatures, air sensor to measure the air mass flow. These parameters are needed to calculate the thermal energy. The monitoring system contains also voltage dividers to measure the PV modules voltage and shunt resistance to measure the PV current, and AC energy meters which are needed to calculate the produced electrical energy. All signals recorded from the thermocouples, voltage dividers and shunt resistances are connected to data loggers. The strategy of cooling in this work was based on switching the fan on, only when the difference between the air duct temperature (under the middle of top of PV column) and the room temperature becomes higher than 5 °C. This strategy was effective in term of avoiding high electrical consumption by the fan, and it is recommended for further development. The temperature difference of 5 °C is the minimum value to compensate the heat losses in the collecting duct and distribution duct. The PVT air collector has an area of (Ac=32 m2), and air mass flow of 0.002 kg/s m2. The nominal output power of the collector is 4 kWppv (34 CIGS modules with 115 Wppvfor each module). The collector produces thermal output energy of 6.88 kWth/day (0.21 kWth/m2 day) and an electrical output energy of 13.46 kWhel/day (0.42 kWhel/m2 day) with cooling case. The PVT air collector has a daily thermal energy yield of 1.72 kWhth/kWppv, and a daily PV electrical energy yield of 3.36 kWhel /kWppv. The fan energy requirement in this case was 0.18 kWh/day which is very small compared to the electrical energy generated by the PV collector. The obtained thermal efficiency was 8 % which is small compared to the results reported in literature for PVT air collectors. The small thermal efficiency was due to small operating air mass flow. Therefore, the study suggests increasing the air mass flow by a factor of 25. The electrical efficiency was fluctuating around 14 %, which is higher than the theoretical efficiency of the PV modules, and this discrepancy was due to the poor method of recording the solar irradiance in the location. Due to shading effect, it was better to use more than one pyranometer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper seeks to describe and discuss the impact of inspections of schools in Sweden. It outlines the political context, based on New Public Management (NPM) theory, according to what role the Schools Inspectorate is supposed to play in order to govern and control. Attention is also devoted, referring an on-going case study, to how inspections influence head teachers and their leadership in their everyday work.   Reports from the Schools inspectorate are public. This forces both politicians and head teachers to take measures. In this case, the head teachers perceived that the inspection reports confirmed what they already knew, but it also gave them an alibi and a tool to push their teachers to take part in everyday school development work. During the first year after the inspection the head teachers mainly strived to adjust formal deficiencies in local steering documents. However, some of the deviations reported from the Schools inspectorate are regarding pedagogical problems that are complicated and difficult to handle. As interventions in many cases will show up much later the results are, for example as increased goal fulfilment, in this case, still an open question. Nevertheless, it seems obvious that the Schools Inspectorate must be seen as a result of the governing philosophy that denotes New Public Management NPM).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Woodworking industries still consists of wood dust problems. Young workers are especially vulnerable to safety risks. To reduce risks, it is important to change attitudes and increase knowledge about safety. Safety training have shown to establish positive attitudes towards safety among employees. The aim of current study is to analyze the effect of QR codes that link to Picture Mix EXposure (PIMEX) videos by analyzing attitudes to this safety training method and safety in student responses. Safety training videos were used in upper secondary school handicraft programs to demonstrate wood dust risks and methods to decrease exposure to wood dust. A preliminary study was conducted to investigate improvement of safety training in two schools in preparation for the main study that investigated a safety training method in three schools. In the preliminary study the PIMEX method was first used in which students were filmed while wood dust exposure was measured and subsequently displayed on a computer screen in real time. Before and after the filming, teachers, students, and researchers together analyzed wood dust risks and effective measures to reduce exposure to them. For the main study, QR codes linked to PIMEX videos were attached at wood processing machines. Subsequent interviews showed that this safety training method enables students in an early stage of their life to learn about risks and safety measures to control wood dust exposure. The new combination of methods can create awareness, change attitudes and motivation among students to work more frequently to reduce wood dust.