4 resultados para Modelling lifetime data

em Dalarna University College Electronic Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is concerned with the use of the choice experiment method for modeling the demand for snowmobiling . The Choice Experiment includes five attributes, standard, composition, length, price day card and experience along trail. The paper estimates the snowmobile owners’ preferences and the most preferred attributes, including their will-ingness to pay for a daytrip on groomed snowmobile trail. The data consists of the an-swers from 479 registered snowmobile owners, who answered two hypothetical choice questions each. Estimating using the multinominal logit model, it is found that snow-mobilers on average are willing to pay 22.5 SEK for one day of snowmobiling on a trail with quality described as skidded every 14th day. Furthermore, it is found that the WTP increases with the quality of trail grooming. The result of this paper can be used as a yardstick for snowmobile clubs wanting to develop their trail net worth, organizations and companies developing snowmobiling as a recreational activities and marketers in-terested in marketing snowmobiling as recreational activities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ghana faces a macroeconomic problem of inflation for a long period of time. The problem in somehow slows the economic growth in this country. As we all know, inflation is one of the major economic challenges facing most countries in the world especially those in African including Ghana. Therefore, forecasting inflation rates in Ghana becomes very important for its government to design economic strategies or effective monetary policies to combat any unexpected high inflation in this country. This paper studies seasonal autoregressive integrated moving average model to forecast inflation rates in Ghana. Using monthly inflation data from July 1991 to December 2009, we find that ARIMA (1,1,1)(0,0,1)12 can represent the data behavior of inflation rate in Ghana well. Based on the selected model, we forecast seven (7) months inflation rates of Ghana outside the sample period (i.e. from January 2010 to July 2010). The observed inflation rate from January to April which was published by Ghana Statistical Service Department fall within the 95% confidence interval obtained from the designed model. The forecasted results show a decreasing pattern and a turning point of Ghana inflation in the month of July.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study reported here is part of a large project for evaluation of the Thermo-Chemical Accumulator (TCA), a technology under development by the Swedish company ClimateWell AB. The studies concentrate on the use of the technology for comfort cooling. This report concentrates on measurements in the laboratory, modelling and system simulation. The TCA is a three-phase absorption heat pump that stores energy in the form of crystallised salt, in this case Lithium Chloride (LiCl) with water being the other substance. The process requires vacuum conditions as with standard absorption chillers using LiBr/water. Measurements were carried out in the laboratories at the Solar Energy Research Center SERC, at Högskolan Dalarna as well as at ClimateWell AB. The measurements at SERC were performed on a prototype version 7:1 and showed that this prototype had several problems resulting in poor and unreliable performance. The main results were that: there was significant corrosion leading to non-condensable gases that in turn caused very poor performance; unwanted crystallisation caused blockages as well as inconsistent behaviour; poor wetting of the heat exchangers resulted in relatively high temperature drops there. A measured thermal COP for cooling of 0.46 was found, which is significantly lower than the theoretical value. These findings resulted in a thorough redesign for the new prototype, called ClimateWell 10 (CW10), which was tested briefly by the authors at ClimateWell. The data collected here was not large, but enough to show that the machine worked consistently with no noticeable vacuum problems. It was also sufficient for identifying the main parameters in a simulation model developed for the TRNSYS simulation environment, but not enough to verify the model properly. This model was shown to be able to simulate the dynamic as well as static performance of the CW10, and was then used in a series of system simulations. A single system model was developed as the basis of the system simulations, consisting of a CW10 machine, 30 m2 flat plate solar collectors with backup boiler and an office with a design cooling load in Stockholm of 50 W/m2, resulting in a 7.5 kW design load for the 150 m2 floor area. Two base cases were defined based on this: one for Stockholm using a dry cooler with design cooling rate of 30 kW; one for Madrid with a cooling tower with design cooling rate of 34 kW. A number of parametric studies were performed based on these two base cases. These showed that the temperature lift is a limiting factor for cooling for higher ambient temperatures and for charging with fixed temperature source such as district heating. The simulated evacuated tube collector performs only marginally better than a good flat plate collector if considering the gross area, the margin being greater for larger solar fractions. For 30 m2 collector a solar faction of 49% and 67% were achieved for the Stockholm and Madrid base cases respectively. The average annual efficiency of the collector in Stockholm (12%) was much lower than that in Madrid (19%). The thermal COP was simulated to be approximately 0.70, but has not been possible to verify with measured data. The annual electrical COP was shown to be very dependent on the cooling load as a large proportion of electrical use is for components that are permanently on. For the cooling loads studied, the annual electrical COP ranged from 2.2 for a 2000 kWh cooling load to 18.0 for a 21000 kWh cooling load. There is however a potential to reduce the electricity consumption in the machine, which would improve these figures significantly. It was shown that a cooling tower is necessary for the Madrid climate, whereas a dry cooler is sufficient for Stockholm although a cooling tower does improve performance. The simulation study was very shallow and has shown a number of areas that are important to study in more depth. One such area is advanced control strategy, which is necessary to mitigate the weakness of the technology (low temperature lift for cooling) and to optimally use its strength (storage).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this paper is to develop a flexible model for analysis of quantitative trait loci (QTL) in outbred line crosses, which includes both additive and dominance effects. Our flexible intercross analysis (FIA) model accounts for QTL that are not fixed within founder lines and is based on the variance component framework. Genome scans with FIA are performed using a score statistic, which does not require variance component estimation. RESULTS: Simulations of a pedigree with 800 F2 individuals showed that the power of FIA including both additive and dominance effects was almost 50% for a QTL with equal allele frequencies in both lines with complete dominance and a moderate effect, whereas the power of a traditional regression model was equal to the chosen significance value of 5%. The power of FIA without dominance effects included in the model was close to those obtained for FIA with dominance for all simulated cases except for QTL with overdominant effects. A genome-wide linkage analysis of experimental data from an F2 intercross between Red Jungle Fowl and White Leghorn was performed with both additive and dominance effects included in FIA. The score values for chicken body weight at 200 days of age were similar to those obtained in FIA analysis without dominance. CONCLUSION: We have extended FIA to include QTL dominance effects. The power of FIA was superior, or similar, to standard regression methods for QTL effects with dominance. The difference in power for FIA with or without dominance is expected to be small as long as the QTL effects are not overdominant. We suggest that FIA with only additive effects should be the standard model to be used, especially since it is more computationally efficient.