2 resultados para MOBILE COMMUNICATION

em Dalarna University College Electronic Archive


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background and aims Evaluating status in patients with motor fluctuations is complex and occasional observations/measurements do not give an adequate picture as to the time spent in different states. We developed a test battery to assess advanced Parkinson patients' status consisting of diary assessments and motor tests. This battery was constructed and implemented on a handheld computer with built-in mobile communication. In fluctuating patients, it should typically be used several times daily in the home environment, over periods of about one week. The aim of this battery is to provide status information in order to evaluate treatment effects in clinical practice and research, follow up treatments and disease progression and predict outcome to optimize treatment strategy. Methods Selection of diary questions was based on a previous study with Duodopa® (DIREQT). Tapping tests (with and without visual cueing) and a spiral drawing test were added. Rapid prototyping was used in development of the user interface. An evaluation with two pilot patients was performed before and after receiving new treatments for advanced disease (one received Duodopa® and one received DBS). Speed and proportion missed taps were calculated for the tapping tests and entropy of the radial drawing velocity was calculated for the spiral tests. Test variables were evaluated using non-parametric statistics. Results Post-treatment improvement was detected in both patients in many of the test variables. Conclusions Although validation work remains, preliminary results are promising and the test battery is currently being evaluated in a long-term health economics study with Duodopa® (DAPHNE).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To compare results from various tapping tests with diary responses in advanced PD. Background: A home environment test battery for assessing patient state in advanced PD, consisting of diary assessments and motor tests was constructed for a hand computer with touch screen and mobile communication. The diary questions: 1. walking, 2. time in off , on and dyskinetic states, 3. off at worst, 4. dyskinetic at worst, 5. cramps, and 6. satisfied with function, relate to the recent past. Question 7, self-assessment, allows seven steps from -3 ( very off ) to +3 ( very dyskinetic ) and relate to right now. Tapping tests outline: 8. Alternately tapping two fields (un-cued) with right hand 9. Same as 8 but using left hand 10. Tapping an active field (out of two) following a system-generated rhythm (increasing speed) with the dominant hand 11. Tapping an active field (out of four) that randomly changes location when tapped using the dominant hand Methods: 65 patients (currently on Duodopa, or candidates for this treatment) entered diary responses and performed tapping tests four times per day during one to six periods of seven days length. In total there were 224 test periods and 6039 test occasions. Speed for tapping test 10 was discardedand tests 8 and 9 were combined by taking means. Descriptive statistics were used to present the variation of the test variables in relation to self assessment (question 7). Pearson correlation coefficients between speed and accuracy (percent correct) in tapping tests and diary responses were calculated. Results: Mean compliance (percentage completed test occasions per test period) was 83% and the median was 93%. There were large differences in both mean tapping speed and accuracy between the different self-assessed states. Correlations between diary responses and tapping results were small (-0.2 to 0.3, negative values for off-time and dyskinetic-time that had opposite scale directions). Correlations between tapping results were all positive (0.1 to 0.6). Conclusions: The diary responses and tapping results provided different information. The low correlations can partly be explained by the fact that questions related to the past and by random variability, which could be reduced by taking means over test periods. Both tapping speed and accuracy reflect the motor function of the patient to a large extent.