4 resultados para Low Reynolds-Number

em Dalarna University College Electronic Archive


Relevância:

90.00% 90.00%

Publicador:

Resumo:

A literature survey and a theoretical study were performed to characterize residential chimney conditions for flue gas flow measurements. The focus is on Pitot-static probes to give sufficient basis for the development and calibration of a velocity pressure averaging probe suitable for the continuous dynamic (i.e. non steady state) measurement of the low flow velocities present in residential chimneys. The flow conditions do not meet the requirements set in ISO 10780 and ISO 3966 for Pitot-static probe measurements, and the methods and their uncertainties are not valid. The flow velocities in residential chimneys from a heating boiler under normal operating condi-tions are shown to be so low that they in some conditions result in voiding the assumptions of non-viscous fluid justifying the use of the quadratic Bernoulli equation. A non-linear Reynolds number dependent calibration coefficient that is correcting for the viscous effects is needed to avoid significant measurement errors. The wide range of flow velocity during normal boiler operation also results in the flow type changing from laminar, across the laminar to turbulent transition region, to fully turbulent flow, resulting in significant changes of the velocity profile during dynamic measurements. In addition, the short duct lengths (and changes of flow direction and duct shape) used in practice are shown to result in that the measurements are done in the hydrodynamic entrance region where the flow velocity profiles most likely are neither symmetrical nor fully developed. A measurement method insensitive to velocity profile changes is thus needed, if the flow velocity profile cannot otherwise be determined or predicted with reasonable accuracy for the whole measurement range. Because of particulate matter and condensing fluids in the flue gas it is beneficial if the probe can be constructed so that it can easily be taken out for cleaning, and equipped with a locking mechanism to always ensure the same alignment in the duct without affecting the calibration. The literature implies that there may be a significant time lag in the measurements of low flow rates due to viscous effects in the internal impact pressure passages of Pitot probes, and the significance in the discussed application should be studied experimentally. The measured differential pressures from Pitot-static probes in residential chimney flows are so low that the calibration and given uncertainties of commercially available pressure transducers are not adequate. The pressure transducers should be calibrated specifically for the application, preferably in combination with the probe, and the significance of all different error sources should be investigated carefully. Care should be taken also with the temperature measurement, e.g. with averaging of several sensors, as significant temperature gradients may be present in flue gas ducts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The genetic improvement in litter size in pigs has been substantial during the last 10-15 years. The number of teats on the sow must increase as well to meet the needs of the piglets, because each piglet needs access to its own teat. We applied a genetic heterogeneity model on teat numberin sows, and estimated medium-high heritability for teat number (0.5), but low heritability for residual variance (0.05), indicating that selection for reduced variance might have very limited effect. A numerically positive correlation (0.8) between additive genetic breeding values for mean and for variance was found, but because of the low heritability for residual variance, the variance will increase very slowly with the mean.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Studies evaluating acceptability of simplified follow-up after medical abortion have focused on high-resource or urban settings where telephones, road connections, and modes of transport are available and where women have formal education. Objective: To investigate women's acceptability of home-assessment of abortion and whether acceptability of medical abortion differs by in-clinic or home-assessment of abortion outcome in a low-resource setting in India. Design: Secondary outcome of a randomised, controlled, non-inferiority trial. Setting Outpatient primary health care clinics in rural and urban Rajasthan, India. Population: Women were eligible if they sought abortion with a gestation up to 9 weeks, lived within defined study area and agreed to follow-up. Women were ineligible if they had known contraindications to medical abortion, haemoglobin < 85mg/l and were below 18 years. Methods: Abortion outcome assessment through routine clinic follow-up by a doctor was compared with home-assessment using a low-sensitivity pregnancy test and a pictorial instruction sheet. A computerized random number generator generated the randomisation sequence (1: 1) in blocks of six. Research assistants randomly allocated eligible women who opted for medical abortion (mifepristone and misoprostol), using opaque sealed envelopes. Blinding during outcome assessment was not possible. Main outcome measures: Women's acceptability of home-assessment was measured as future preference of follow-up. Overall satisfaction, expectations, and comparison with previous abortion experiences were compared between study groups. Results: 731 women were randomized to the clinic follow-up group (n = 353) or home-assessment group (n = 378). 623 (85%) women were successfully followed up, of those 597 (96%) were satisfied and 592 (95%) found the abortion better or as expected, with no difference between study groups. The majority, 355 (57%) women, preferred home-assessment in the event of a future abortion. Significantly more women, 284 (82%), in the home-assessment group preferred home-assessment in the future, as compared with 188 (70%) of women in the clinic follow-up group, who preferred clinic follow-up in the future (p < 0.001). Conclusion: Home-assessment is highly acceptable among women in low-resource, and rural, settings. The choice to follow-up an early medical abortion according to women's preference should be offered to foster women's reproductive autonomy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Post-abortion contraceptive use in India is low and the use of modern methods of contraception is rare, especially in rural areas. This study primarily compares contraceptive use among women whose abortion outcome was assessed in-clinic with women who assessed their abortion outcome at home, in a low-resource, primary health care setting. Moreover, it investigates how background characteristics and abortion service provision influences contraceptive use post-abortion. METHODS: A randomized controlled, non-inferiority, trial (RCT) compared clinic follow-up with home-assessment of abortion outcome at 2 weeks post-abortion. Additionally, contraceptive-use at 3 months post-abortion was investigated through a cross-sectional follow-up interview with a largely urban sub-sample of women from the RCT. Women seeking abortion with a gestational age of up to 9 weeks and who agreed to a 2-week follow-up were included (n = 731). Women with known contraindications to medical abortions, Hb < 85 mg/l and aged below 18 were excluded. Data were collected between April 2013 and August 2014 in six primary health-care clinics in Rajasthan. A computerised random number generator created the randomisation sequence (1:1) in blocks of six. Contraceptive use was measured at 2 weeks among women successfully followed-up (n = 623) and 3 months in the sub-set of women who were included if they were recruited at one of the urban study sites, owned a phone and agreed to a 3-month follow-up (n = 114). RESULTS: There were no differences between contraceptive use and continuation between study groups at 3 months (76 % clinic follow-up, 77 % home-assessment), however women in the clinic follow-up group were most likely to adopt a contraceptive method at 2 weeks (62 ± 12 %), while women in the home-assessment group were most likely to adopt a method after next menstruation (60 ± 13 %). Fifty-two per cent of women who initiated a method at 2 weeks chose the 3-month injection or the copper intrauterine device. Only 4 % of women preferred sterilization. Caste, educational attainment, or type of residence did not influence contraceptive use. CONCLUSIONS: Simplified follow-up after early medical abortion will not change women's opportunities to access contraception in a low-resource setting, if contraceptive services are provided as intra-abortion services as early as on day one. Women's postabortion contraceptive use at 3 months is unlikely to be affected by mode of followup after medical abortion, also in a low-resource setting. Clinical guidelines need to encourage intra-abortion contraception, offering the full spectrum of evidence-based methods, especially long-acting reversible methods. TRIAL REGISTRATION: Clinicaltrials.gov NCT01827995.