6 resultados para Inserted Thermocouples
em Dalarna University College Electronic Archive
Resumo:
To increase the quality in their products ABB is working towards a cleared order concept. That means that all customer specified options are to be known before they start with order calculations and construction. As it is today they use paper checklists to achieve this. One order may have several reactors, and for a reactor there can be several different alternatives. For each alternative a new checklist must be filled out.As of today all reading of the customer specification and checklist fill in with is done by hand by different persons, and sometimes the same data is read more than one time. All data is also manually inserted into the calculation tools.To decrease the risk that data is left out or gets distorted they want to have a tool to aid with the reading of the specification and the documentation of that work. Already read data can be copied over to another alternative so that it not must be read one more time. The read data are to be stored in a database so that it easily can be per automation inserted into the different design tools.
Resumo:
Prosodic /template Morphology, that "draws heavily on the theoretical apparatus and formalisms of the generative phonology model known as autosegmental phonology" (Katamba, F. 1993: 154), is the best analysis that can handle Arabic morphology. Verbs in Arabic are represented on three independent tiers: root tier, the skeletal tier and the vocalic melody tier (Katamba, F. 1993). Vowel morphemes, which are represented by diacritics, are inserted within the consonant morphemes, which are represented by primary symbols, to form words. The morpheme tier hypothesis paves the way to understand the nonconcatenative Arabic morphology. This paper analyzes gender in perfect active and passive 3rd person singular verbs on the basis of PM. The focus of the analysis shall be drawn heavily on the most common Arabic verbs; triconsonantal verbs, with brief introduction of the less common verbs; quadriconsonantal perfect active and passive masculine and feminine 3rd person singular verbs. I shall, too, cast the light on some vowel changes that some verbs undergo when voice changes.
Resumo:
PAPRO operates within the Forest Research company and their mission is to develop value-addingindustry solutions. At present there are no good ways for mills to easily test the printing quality on newsprintpaper. There is a great need for a fast way to do this on different paper qualities; with a laboratory-offset press this can be both a time and money saving method. At PAPRO Forest Research, NewZealand, a laboratory offset press has been developed and designed, during the past seven years, concerningthis issue. Earlier projects were made concerning the press, e.g. to establish the optimal settings.The mission with this project was to partly determine the present variability of the print quality andto evaluate if the fountain solution, distilled water and 2% Diol green concentrate, used at the momentmixed with different percentages of Isopropanol could decrease the variability and contribute to morestabile results. Throughout the whole project the print quality showed a high variation and was evenmore variable when the Isopropanol was added. All in all 50 print rounds times twelve printed paperstrips was carried out through the project divided into three parts. To analyse the print quality, amicroscope with an image capture camera has been used. Data from the taken images was analysedand inserted into charts to see the variations.The conclusions of the whole project are not satisfying because no final evaluations were possible tomake. Main conclusions are that the additive of Isopropanol to the ordinary fountain solution, used atpresent, only contributed to more unstable results of the print quality. And it seems to be difficult toget some stable results from the lab press as long as the room where it is placed is not fully conditionedas required for the process of offset printing. And the fact that the airbrush which applies theamount of fountain solution is also variable, as shown in earlier projects, which contributes to unstableresults as well. For further work more exact parameters as a conditioned room are required and thepossibility to further design the laboratory press to use waterless offset printing instead.
Resumo:
In this paper, Finite Element method and full-scale experiments have been used to study a hot forging method for fabri-cation of a spindle using reduced initial stock size. The forging sequence is carried out in two stages. In the first stage, the hot rolled cylindrical billet is pre-formed and pierced in a closed die using a spherical nosed punch to within 20 mm of its base. This process of piercing or impact extrusion leads to high strains within the work piece but requires high press loads. In the second stage, the resulting cylinder is placed in a die with a flange chamber and upset forged to form a flange. The stock mass is optimized for complete die filling. Process parameters such as effective strain distribution, material flow and forging load in different stages of the process are analyzed. It is concluded from the simulations that minor modifications of piercing punch geometry to reduce contact between the punch and emerging vertical walls of the cylinder appreciably reduces the piercing load. In the flange chamber, a die surfaces angle of 52° instead of 45° is pro-posed to ensure effective material flow and exert sufficient tool pressure to achieve complete cavity filling. In order to achieve better compression, it is also proposed to shorten both the length of the inserted punch and the die “tongues” by a few mm.
Resumo:
This is a note about proxy variables and instruments for identification of structural parameters in regression models. We have experienced that in the econometric textbooks these two issues are treated separately, although in practice these two concepts are very often combined. Usually, proxy variables are inserted in instrument variable regressions with the motivation they are exogenous. Implicitly meaning they are exogenous in a reduced form model and not in a structural model. Actually if these variables are exogenous they should be redundant in the structural model, e.g. IQ as a proxy for ability. Valid proxies reduce unexplained variation and increases the efficiency of the estimator of the structural parameter of interest. This is especially important in situations when the instrument is weak. With a simple example we demonstrate what is required of a proxy and an instrument when they are combined. It turns out that when a researcher has a valid instrument the requirements on the proxy variable is weaker than if no such instrument exists
Resumo:
Hybrid Photovoltaic Thermal (PVT) collectors are an emerging technology that combines PV and solar thermal systems in a single solar collector producing heat and electricity simultaneously. The focus of this thesis work is to evaluate the performance of unglazed open loop PVT air system integrated on a garage roof in Borlänge. As it is thought to have a significant potential for preheating ventilation of the building and improving the PV modules electrical efficiency. The performance evaluation is important to optimize the cooling strategy of the collector in order to enhance its electrical efficiency and maximize the production of thermal energy. The evaluation process involves monitoring the electrical and thermal energies for a certain period of time and investigating the cooling effect on the performance through controlling the air mass flow provided by a variable speed fan connected to the collector by an air distribution duct. The distribution duct transfers the heated outlet air from the collector to inside the building. The PVT air collector consists of 34 Solibro CIGS type PV modules (115 Wp for each module) which are roof integrated and have replaced the traditional roof material. The collector is oriented toward the south-west with a tilt of 29 ᵒ. The collector consists of 17 parallel air ducts formed between the PV modules and the insulated roof surface. Each air duct has a depth of 0.05 m, length of 2.38 m and width of 2.38 m. The air ducts are connected to each other through holes. The monitoring system is based on using T-type thermocouples to measure the relevant temperatures, air sensor to measure the air mass flow. These parameters are needed to calculate the thermal energy. The monitoring system contains also voltage dividers to measure the PV modules voltage and shunt resistance to measure the PV current, and AC energy meters which are needed to calculate the produced electrical energy. All signals recorded from the thermocouples, voltage dividers and shunt resistances are connected to data loggers. The strategy of cooling in this work was based on switching the fan on, only when the difference between the air duct temperature (under the middle of top of PV column) and the room temperature becomes higher than 5 °C. This strategy was effective in term of avoiding high electrical consumption by the fan, and it is recommended for further development. The temperature difference of 5 °C is the minimum value to compensate the heat losses in the collecting duct and distribution duct. The PVT air collector has an area of (Ac=32 m2), and air mass flow of 0.002 kg/s m2. The nominal output power of the collector is 4 kWppv (34 CIGS modules with 115 Wppvfor each module). The collector produces thermal output energy of 6.88 kWth/day (0.21 kWth/m2 day) and an electrical output energy of 13.46 kWhel/day (0.42 kWhel/m2 day) with cooling case. The PVT air collector has a daily thermal energy yield of 1.72 kWhth/kWppv, and a daily PV electrical energy yield of 3.36 kWhel /kWppv. The fan energy requirement in this case was 0.18 kWh/day which is very small compared to the electrical energy generated by the PV collector. The obtained thermal efficiency was 8 % which is small compared to the results reported in literature for PVT air collectors. The small thermal efficiency was due to small operating air mass flow. Therefore, the study suggests increasing the air mass flow by a factor of 25. The electrical efficiency was fluctuating around 14 %, which is higher than the theoretical efficiency of the PV modules, and this discrepancy was due to the poor method of recording the solar irradiance in the location. Due to shading effect, it was better to use more than one pyranometer.