12 resultados para Indoor

em Dalarna University College Electronic Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research was carried out by studying possible renovation of a two-storey detached multifamily building by using passive solar design options in a cold climate in Borlänge, Sweden where the heating Degree Days are 4451 (base 20°C). Borlänge`s housing company, Tunabyggen, plans to renovate the project house located inthe multicultural district, Jakobsgårdarna. The goal of the thesis was to suggest a redesign of the current building, decrease the heating energy use, by applying passive solar design and control strategies, in a most reasonable way. In addition ensure a better thermal comfort for the tenants in the dwellings. Literatures have been studied, from which can be inferred that passive design should be abasic design consideration for all housing constructions, because it has advantages to ensure thermal comfort, and reduce the energy use. In addition further savings can be achieved applying different types of control strategies, from which the house will be more personalized, and better adapted to the user’s needs.The proposed method is based on simulations by using TRNSYS software. First a proper building model was set up, which represents the current state of the project building. Then the thermal insulation and the windows were upgraded, based on today's building regulations. The developments of the passive solar options were accomplished in two steps. First of all the relevant basic passive design elements were considered, then those advantages were compared to the advantages of applying new conventional thermostat, and shading control strategies.The results show that there is significant potential with the different types of passive solar design; their usage depends primarily on the location of the site as well as the orientation of the project building. Applying the control strategies, such as thermostat, and shading control, along the thermal insulation upgrade, may lead to significant energy savings (around 40 %), by comparison to the reference building without any upgrade.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis is related to the broad subject of automatic motion detection and analysis in videosurveillance image sequence. Besides, proposing the new unique solution, some of the previousalgorithms are evaluated, where some of the approaches are noticeably complementary sometimes.In real time surveillance, detecting and tracking multiple objects and monitoring their activities inboth outdoor and indoor environment are challenging task for the video surveillance system. Inpresence of a good number of real time problems limits scope for this work since the beginning. Theproblems are namely, illumination changes, moving background and shadow detection.An improved background subtraction method has been followed by foreground segmentation, dataevaluation, shadow detection in the scene and finally the motion detection method. The algorithm isapplied on to a number of practical problems to observe whether it leads us to the expected solution.Several experiments are done under different challenging problem environment. Test result showsthat under most of the problematic environment, the proposed algorithm shows the better qualityresult.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Different shapes of asymmetric awnings for east and west windows are investigated mathematically as well as by measurement in a model. A box with 90 cm side and a 30x30 cm window was placed outdoor in overcast weather and the daylight factor was measured at the bottom of the box when the window was unshaded or equipped with different awnings. The average daylight factor in the box decreased from 4.6% for the unshaded window to 1.0% when a full awning was used. With “the best” asymmetrical awning, the average daylight factor was 80% larger than with the full awing. Using Dutch climate, calculation of the energy from direct radiation transmitted through the window during the cooling season showed that this was decreased from 100% as an annual mean for the unshaded window down 22% with a full awing. With “the best” asymmetrical awning, 26% of the energy was transmitted. Calculation of the indoor temperature in a hypothetical row house in Netherlands show that the use of either normal or asymmetrical awnings considerable decrease the indoor temperature during the hot season. Therefore the use of asymmetrical awnings for east or west faced windows considerable can increase the daylight in buildings, with almost no change in overheating, compared to if traditional awnings are used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An international standard, ISO/DP 9459-4 has been proposed to establish a uniform standard of quality for small, factory-made solar heating systerns. In this proposal, system components are tested separatelyand total system performance is calculated using system simulations based on component model parameter values validated using the results from the component tests. Another approach is to test the whole system in operation under representative conditions, where the results can be used as a measure of the general system performance. The advantage of system testing of this form is that it is not dependent on simulations and the possible inaccuracies of the models. Its disadvantage is that it is restricted to the boundary conditions for the test. Component testing and system simulation is flexible, but requires an accurate and reliable simulation model.The heat store is a key component conceming system performance. Thus, this work focuses on the storage system consisting store, electrical auxiliary heater, heat exchangers and tempering valve. Four different storage system configurations with a volume of 750 litre were tested in an indoor system test using a six -day test sequence. A store component test and system simulation was carried out on one of the four configurations, applying the proposed standard for stores, ISO/DP 9459-4A. Three newly developed test sequences for intemalload side heat exchangers, not in the proposed ISO standard, were also carried out. The MULTIPORT store model was used for this work. This paper discusses the results of the indoor system test, the store component test, the validation of the store model parameter values and the system simulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The need for heating and cooling in buildings constitutes a considerable part of the total energy use in a country and reducing this need is of outmost importance in order to reach national and international goals for reducing energy use and emissions. One important way of reaching these goals is to increase the proportion of renewable energy used for heating and cooling of buildings. Perhaps the largest obstacle with this is the often occurring mismatch between the availability of renewable energy and the need for heating or cooling, hindering this energy to be used directly. This is one of the problems that can be solved by using thermal energy storage (TES) in order to save the heat or cold from when it is available to when it is needed. This thesis is focusing on the combination of TES techniques and buildings to achieve increased energy efficiency for heating and cooling. Various techniques used for TES as well as the combination of TES in buildings have been investigated and summarized through an extensive literature review. A survey of the Swedish building stock was also performed in order to define building types common in Sweden. Within the scope of this thesis, the survey resulted in the selection of three building types, two single family houses and one office building, out of which the two residential buildings were used in a simulation case study of passive TES with increased thermal mass (both sensible and latent). The second case study presented in the thesis is an evaluation of an existing seasonal borehole storage of solar heat for a residential community. In this case, real measurement data was used in the evaluation and in comparisons with earlier evaluations. The literature reviews showed that using TES opens up potential for reduced energy demand and reduced peak heating and cooling loads as well as possibilities for an increased share of renewable energy to cover the energy demand. By using passive storage through increased thermal mass of a building it is also possible to reduce variations in the indoor temperature and especially reduce excess temperatures during warm periods, which could result in avoiding active cooling in a building that would otherwise need it. The analysis of the combination of TES and building types confirmed that TES has a significant potential for increased energy efficiency in buildings but also highlighted the fact that there is still much research required before some of the technologies can become commercially available. In the simulation case study it was concluded that only a small reduction in heating demand is possible with increased thermal mass, but that the time with indoor temperatures above 24 °C can be reduced by up to 20%. The case study of the borehole storage system showed that although the storage system worked as planned, heat losses in the rest of the system as well as some problems with the system operation resulted in a lower solar fraction than projected. The work presented within this thesis has shown that TES is already used successfully for many building applications (e.g. domestic hot water stores and water tanks for storing solar heat) but that there still is much potential in further use of TES. There are, however, barriers such as a need for more research for some storage technologies as well as storage materials, especially phase change material storage and thermochemical storage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In a Nordic climate, space heating (SH) and domestic hot water (DHW) used in buildings constitute a considerable part of the total energy use in the country. For 2010, energy used for SH and DHW amounted to almost 90 TWh in Sweden which corresponds to 60 % of the energy used in the residential and service sector, or almost 24 % of the total final energy use for the country. Storing heat and cold with the use of thermal energy storage (TES) can be one way of increasing the energy efficiency of a building by opening up possibilities for alternative sources of heat or cold through a reduced mismatch between supply and demand. Thermal energy storage without the use of specific control systems are said to be passive and different applications using passive TES have been shown to increase energy efficiency and/or reduce power peaks of systems supplying the heating and cooling needs of buildings, as well as having an effect on the indoor climate. Results are however not consistent between studies and focus tend to be on the reduction of cooling energy or cooling power peaks. In this paper, passive TES introduced through an increased thermal mass in the building envelope to two single family houses with different insulation standard is investigated with building energy simulations. A Nordic climate is used and the focus of this study is both on the reduction of space heating demand and space heating power, as well as on reduction of excess temperatures in residential single family houses without active cooling systems. Care is taken to keep the building envelope characteristics other than the thermal mass equal for all cases so that any observations made can be derived to the change in thermal mass. Results show that increasing the sensible thermal mass in a single family house can reduce the heating demand only slightly (1-4 %) and reduce excess temperatures (temperatures above 24 degrees C) by up to 20 %. Adding a layer of PCM (phase change materials) to the light building construction can give similar reduction in heating demand and excess temperatures, however the phase change temperature is important for the results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The overall purpose of this study is to gain knowledge about dialogues in the setting of the preschool. The more in-depth purpose is to highlight what happens in dialogues between a teacher and a child when more children join the situation of interaction in which the dialogue is taking place. A further purpose is to attempt to understand what it is that influences change in the dialogue and what significance the actions of the teacher can have for this change. The study is based on several questions that concern interaction in preschools, who it is that initiates an increase in the number of participants in those situations that involve dialogue, and what happens with the dialogue when more children join and what causes the change in the dialogue. The study is based on video observations from a preschool; approximately 10 teachers and 50 children between the ages of one and six took part in the study. The situations that were observed and documented in video format were everyday activities (both indoor and outdoor) that were led at a nominal level by teachers. In total, 40 films were recorded. Film length was between one and 60 minutes. In 32 of the films, there was interaction between a teacher and several children, and 18 of these included dialogues between a teacher and several children. Dialogue is here given a specific significance and refers to the interaction that can be described in terms of presence, listening, reciprocity, and extending. This definition of dialogue derives from a combination of Martin Buber’s philosophy of dialogue and aspects of interaction that earlier research found to be significant for children’s learning. In two of the 18 films that showed dialogue, no other children became part of the situation of interaction; the remaining 16 films were transcribed; and both verbal and non-verbal events were made apparent in the transcriptions. Analyses of the recorded material and of the transcriptions were conducted using analytical terms borrowed from conversation analysis as well as the central term for this study dialogue.  The results demonstrate a complex practice and also demonstrate that dialogues in the sense given in this study take place between children and teachers. Situations of interaction also occur where dialogues take place in which a number of children join. It can be the child joining the situation of interaction who takes the initiative to an increased number of participants; however, it can also be the teacher or the child in the dialogue. The initial address can take place during a moment of transition in the interaction or at the same time as another participant is talking. The dialogue often changes when more children join the situation where the dialogue is taking place. The dialogue can end completely or be interrupted and resume. The results further demonstrate that the dialogue can continue without seemingly being affected by the fact that more children join. This happens when the child joining and the teacher in the dialogue interact in a non-verbal manner at the same time as the teacher is talking with the child in the dialogue. The dialogue can also be continued with more participants. Who takes the initiative, how the initial address occurs, and which content is given focus by the different participants are all factors that seem to affect what happens to the dialogue. How the teacher acts when more children join also appears to be significant in terms of what happens with the dialogue when more children join. In those situations where the teacher begins talking with a number of children about different subjects, the interaction ceases to be dialogic. When the teacher asks the joining child to wait, the dialogue is both interrupted and resumed, and on those occasions when the dialogue continues with more participants, the teacher listens to the joining child and the participants take turns speaking.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapporten ingår i ett FoU- projekt för Högskolan Dalarna, där målet är att ta fram en konstruktion utan ångspärr som ska klara dagens mått på lufttäthet och fuktkrav. Syftet med denna rapport är att utreda hur fukt påverkar en byggnad medmassivträstomme och olika isoleringsmaterial utan ångspärr. Mineralull och träfiberisolering jämförs mot varandra för att se hur dessa påverkarfuktbelastningen i en väggkonstruktion. Testobjektet är lokaliserat i Dalarna, inget fukttillskott har funnits inomhus i byggnaden. För att genomföra detta arbete har tre stycken olika metoder används. Ensimulering, verkliga uppmätta värden och en provtagning. Fuktsimuleringen genomfördes med hjälp av programmet WUFI, uppmätta värden i form av relativ fuktighet och temperatur har samlats in kontinuerligt under två års tid från väggkonstruktionen via mätsensorer. Provtagningen utfördes med ett fysiskt ingrepp på samma nivå i konstruktionen som mätsensorer var placerade. Resultat presenteras i form av diagram och tabeller där det går att avläsa konstruktionens nulägesstatus i form av relativ fuktighet, temperatur, fuktkvot och mikrobiologisk påväxt. Isoleringsmaterialen påvisar en hög relativ fuktighet under vinterhalvåret längst ut i konstruktionen mot utomhusklimatet. Utomhusklimatet har visats spela stor roll i detta. Ingen direkt mikrobiologisk påväxt har påträffats trots en hög halt av fukt. Resultaten visar att träfiberisoleringen har bättre förmåga att hantera fukt i jämförelse med mineralullen. En vidarestudie med fuktbelastning och 21 °C inomhus bör utföras. Men för att denna studie ska fungera rekommenderas en tvåstegstätad fasadlösning för att klara fuktbelastningen i väggkonstruktionen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Viewed from a historical perspective, a shift has occurred within the forestry and wood sector towards indoor work. In Sweden, the production of handcrafted log houses has now also begun to move indoors. With a point of departure in development processes within the log house sector involving working indoors, education, work attractiveness, between 2001-2005, the aim of this study was to compare indoor work with outdoor work, based on log house builders' experience of working on handcrafted log houses. Methods used in the interactive development project involving apprentices, experienced log house builders and researchers, were participation with continuous documentation of experiences and opinions; questions; interviews; and measurement of the work environment. The Attractive Work Model has been used in order to analyse perceptions and values. The changes, 15 out of 22 areas, were perceived both negatively and positively. Therefore, it can not be said that working on traditional, handcrafted log houses becomes more attractive if it is moved indoors. The majority wanted to work both outdoors and indoors, while most of the others only wanted to work outdoors. The results indicate that there is scope for developing more attractive work indoors by utilising experiences from log house builders and closely related activities such as the forestry and wood sector. Changes made within one area of work attractiveness affect other areas. Further research is needed both with regard to comparisons between indoor and outdoor work and regarding the interaction between the areas that are identified in the Attractive Work Model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The demand for cooling and air-conditioning of building is increasingly ever growing. This increase is mostly due to population and economic growth in developing countries, and also desire for a higher quality of thermal comfort. Increase in the use of conventional cooling systems results in larger carbon footprint and more greenhouse gases considering their higher electricity consumption, and it occasionally creates peaks in electricity demand from power supply grid. Solar energy as a renewable energy source is an alternative to drive the cooling machines since the cooling load is generally high when solar radiation is high. This thesis examines the performance of PV/T solar collector manufactured by Solarus company in a solar cooling system for an office building in Dubai, New Delhi, Los Angeles and Cape Town. The study is carried out by analyzing climate data and the requirements for thermal comfort in office buildings. Cooling systems strongly depend on weather conditions and local climate. Cooling load of buildings depend on many parameters such as ambient temperature, indoor comfort temperature, solar gain to the building and internal gains including; number of occupant and electrical devices. The simulations were carried out by selecting a suitable thermally driven chiller and modeling it with PV/T solar collector in Polysun software. Fractional primary energy saving and solar fraction were introduced as key figures of the project to evaluate the performance of cooling system. Several parametric studies and simulations were determined according to PV/T aperture area and hot water storage tank volume. The fractional primary energy saving analysis revealed that thermally driven chillers, particularly adsorption chillers are not suitable to be utilizing in small size of solar cooling systems in hot and tropic climates such as Dubai and New Delhi. Adsorption chillers require more thermal energy to meet the cooling load in hot and dry climates. The adsorption chillers operate in their full capacity and in higher coefficient of performance when they run in a moderate climate since they can properly reject the exhaust heat. The simulation results also indicated that PV/T solar collector have higher efficiency in warmer climates, however it requires a larger size of PV/T collectors to supply the thermally driven chillers for providing cooling in hot climates. Therefore using an electrical chiller as backup gives much better results in terms of primary energy savings, since PV/T electrical production also can be used for backup electrical chiller in a net metering mechanism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent studies have shown that the optical properties of building exterior surfaces are important in terms of energy use and thermal comfort. While the majority of the studies are related to exterior surfaces, the radiation properties of interior surfaces are less thoroughly investigated. Development in the coil-coating industries has now made it possible to allocate different optical properties for both exterior and interior surfaces of steel-clad buildings. The aim of this thesis is to investigate the influence of surface radiation properties with the focus on the thermal emittance of the interior surfaces, the modeling approaches and their consequences in the context of the building energy performance and indoor thermal environment. The study consists of both numerical and experimental investigations. The experimental investigations include parallel field measurements on three similar test cabins with different interior and exterior surface radiation properties in Borlänge, Sweden, and two ice rink arenas with normal and low emissive ceiling in Luleå, Sweden. The numerical methods include comparative simulations by the use of dynamic heat flux models, Building Energy Simulation (BES), Computational Fluid Dynamics (CFD) and a coupled model for BES and CFD. Several parametric studies and thermal performance analyses were carried out in combination with the different numerical methods. The parallel field measurements on the test cabins include the air, surface and radiation temperatures and energy use during passive and active (heating and cooling) measurements. Both measurement and comparative simulation results indicate an improvement in the indoor thermal environment when the interior surfaces have low emittance. In the ice rink arenas, surface and radiation temperature measurements indicate a considerable reduction in the ceiling-to-ice radiation by the use of low emittance surfaces, in agreement with a ceiling-toice radiation model using schematic dynamic heat flux calculations. The measurements in the test cabins indicate that the use of low emittance surfaces can increase the vertical indoor air temperature gradients depending on the time of day and outdoor conditions. This is in agreement with the transient CFD simulations having the boundary condition assigned on the exterior surfaces. The sensitivity analyses have been performed under different outdoor conditions and surface thermal radiation properties. The spatially resolved simulations indicate an increase in the air and surface temperature gradients by the use of low emittance coatings. This can allow for lower air temperature at the occupied zone during the summer. The combined effect of interior and exterior reflective coatings in terms of energy use has been investigated by the use of building energy simulation for different climates and internal heat loads. The results indicate possible energy savings by the smart choice of optical properties on interior and exterior surfaces of the building. Overall, it is concluded that the interior reflective coatings can contribute to building energy savings and improvement of the indoor thermal environment. This can be numerically investigated by the choice of appropriate models with respect to the level of detail and computational load. This thesis includes comparative simulations at different levels of detail.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: In light of the multifactorial etiology of fall-related hip fracture, knowledge of fall circumstances may be especially valuable when placed in the context of the health of the person who falls. We aimed to investigate the circumstances surrounding fall-related hip fractures and to describe fall circumstances in relation to participants' health and functional characteristics. Methods: The fall circumstances of 125 individuals (age >= 50 years) with hip fracture were investigated using semi-structured interviews. Data concerning participants' health (comorbidities and medications) and function (self-reported performance of mobility, balance, personal activities of daily living and physical activity, previous falls and hand grip strength) were collected via medical records, questionnaires and dynamometry. Using a mixed methods design, both data sets were analysed separately and then merged in order to provide a comprehensive description of fall events and identify eventual patterns in the data. Results: Fall circumstances were described as i) Activity at the time of the fall: Positional change (n = 24, 19%); Standing (n = 16, 13%); Walking (n = 71, 57%); Balance challenging (n = 14, 11%) and ii) Nature of the fall: Environmental (n = 32, 26%); Physiological (n = 35, 28%); Activity-related indoor (n = 8, 6%) and outdoor (n = 8, 6%); Trips and slips on snow (n = 20, 16%) and in snow-free conditions (n = 12, 10%) and Unknown (n = 10, 8%). We observed the following patterns regarding fall circumstances and participants' health: those who fell i) during positional change had the poorest functional status; ii) due to environmental reasons (indoors) had moderate physical function, but high levels of comorbidity and fall risk increasing medications; iii) in snow-free environments (outdoors) appeared to have a poorer health and functional status than other outdoor groups. Conclusions: Our findings indicate that patterns exist in relation to the falls circumstances and health characteristics of people with hip fracture which build upon that previously reported. These patterns, when verified, can provide useful information as to the ways in which fall prevention strategies can be tailored to individuals of varying levels of health and function who are at risk for falls and hip fracture.