4 resultados para IT-Integration

em Dalarna University College Electronic Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The client, Senselogic, had noticed an increased demand for an e-commerce system integrated into its product, SiteVision, something that did not previously exist. Senselogic wanted to integrate a third-party system to manage e-commerce. The problem was that there were very many e-commerce solutions to choose from. In order to select the best system it was necessary to evaluate the e-commerce systems and compare them to each other. To identify the elements that has to be included in an e-commerce system a study of literature was conducted. From the parts identified in the study of literature, a number of criteria were presented. Those criteria were then supplemented with additional criteria that Senselogic required of an e-commerce system before integrating it with SiteVision. Before the evaluation a number of test cases were created to test whether the ecommerce systems fulfilled to the criteria developed. These test cases were then used in the evaluation of the e-commerce systems while a test score was filled in. Then the evaluations of the different systems were compiled and compared in order to see which system best fulfilled the criteria. There was one system that scored higher than the others in the evaluation created. That was the system chosen to integrate with SiteVision.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Today, there are no standardized ways to characterize SOA, many are talking about SOA and many say they are using SOA. One way that we have chosen to characterize this phenomenon is through an evaluation that will indicate whether SOA have been used in the development. Basedon a Service Oriented Architecture literature study, we have created an evaluation pattern resulting SOA principles of integration, architecture and services. This evaluation was applied to Logica's own integration system AgrCom through an empirical study to result in a response indicating whether AgrCom is SOA based. The results of the evaluation show that AgrCom is part of an SOA solution but not an SOA as a whole concept. The study shows that it takes morethan just systems in an activity to be referred to as the SOA-based, hence the architecture of anactivity must be taken into account.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The demand for cooling and air-conditioning of building is increasingly ever growing. This increase is mostly due to population and economic growth in developing countries, and also desire for a higher quality of thermal comfort. Increase in the use of conventional cooling systems results in larger carbon footprint and more greenhouse gases considering their higher electricity consumption, and it occasionally creates peaks in electricity demand from power supply grid. Solar energy as a renewable energy source is an alternative to drive the cooling machines since the cooling load is generally high when solar radiation is high. This thesis examines the performance of PV/T solar collector manufactured by Solarus company in a solar cooling system for an office building in Dubai, New Delhi, Los Angeles and Cape Town. The study is carried out by analyzing climate data and the requirements for thermal comfort in office buildings. Cooling systems strongly depend on weather conditions and local climate. Cooling load of buildings depend on many parameters such as ambient temperature, indoor comfort temperature, solar gain to the building and internal gains including; number of occupant and electrical devices. The simulations were carried out by selecting a suitable thermally driven chiller and modeling it with PV/T solar collector in Polysun software. Fractional primary energy saving and solar fraction were introduced as key figures of the project to evaluate the performance of cooling system. Several parametric studies and simulations were determined according to PV/T aperture area and hot water storage tank volume. The fractional primary energy saving analysis revealed that thermally driven chillers, particularly adsorption chillers are not suitable to be utilizing in small size of solar cooling systems in hot and tropic climates such as Dubai and New Delhi. Adsorption chillers require more thermal energy to meet the cooling load in hot and dry climates. The adsorption chillers operate in their full capacity and in higher coefficient of performance when they run in a moderate climate since they can properly reject the exhaust heat. The simulation results also indicated that PV/T solar collector have higher efficiency in warmer climates, however it requires a larger size of PV/T collectors to supply the thermally driven chillers for providing cooling in hot climates. Therefore using an electrical chiller as backup gives much better results in terms of primary energy savings, since PV/T electrical production also can be used for backup electrical chiller in a net metering mechanism.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this qualitative user evaluation participants in the project refugee guide, Falun, was interviewed about their experience of the project and how the project contributed to their integration into society and establishment on the labor market. The collection of empirical data has been made by six interviews. The results of the evaluation indicate that participants feel that they through the project had the opportunity to meet new people, practice the language and learn about each other's culture. The results also show that participants are satisfied with the project. Some participants expressed a desire to meet with several people at once while others don´t have that need. Furthermore, the interviews shows that establishment on labor market occurred through job placement and not through participation in the project. Integration proved to be a difficult concept to define, but the interviews show that the participants have a perception that it is about learning the Swedish language and culture.