7 resultados para High Rise Residential
em Dalarna University College Electronic Archive
Resumo:
In the process laboratory of Metso minerals (Sala) AB, continuous tests have been made with a laboratory unit High-Rate thickener. The tests are made in order to compare three methods of thickening techniques of suspended solids. The three techniques are High-Rate thickening, conventional thickening and lamella thickening. The High-Rate and the conventional trials are based on a continuous method, while the lamella thickener is based on batch trials. Because the lamella thickener is based on batch trials and there were some optimization problems with the adding point of the flocculant at the continuous trials, it was not feasible to compare the lamella thickener with the other two thickener types. On the other hand, since the optimization problems were the same for the other two methods there was no problem comparing them. The result of the comparison between the High-Rate thickener and the conventional thickener, was, that the High-Rate thickener manages to work at a higher rise rate with a lower consumption of flocculant than the conventional thickener. Seeing to the unit area that is needed by each thickener it is apparent that the conventional thickener demands a higher unit area than the High-Rate thickener to achieve the same amount of solids in the underflow. It has also been showed that the High-Rate thickener demands a lesser quantity of flocculant at the same amount of suspended solids in the feed than the conventional thickener.
Resumo:
A solar thermal system with seasonal borehole storage for heating of a residential area in Anneberg, Sweden, approximately 10 km north of Stockholm, has been in operation since late 2002. Originally, the project was part of the EU THERMIE project “Large-scale Solar Heating Systems for Housing Developments” (REB/0061/97) and was the first solar heating plant in Europe with borehole storage in rock not utilizing a heat pump. Earlier evaluations of the system show lower performance than the preliminary simulation study, with residents complaining of a high use of electricity for domestic hot water (DHW) preparation and auxiliary heating. One explanation mentioned in the earlier evaluations is that the borehole storage had not yet reached “steady state” temperatures at the time of evaluation. Many years have passed since then and this paper presents results from a new evaluation. The main aim of this work is to evaluate the current performance of the system based on several key figures, as well as on system function based on available measurement data. The analysis show that though the borehole storage now has reached a quasi-steady state and operates as intended, the auxiliary electricity consumption is much higher than the original design values largely due to high losses in the distribution network, higher heat loads as well as lower solar gains.
Resumo:
With the building sector accounting for around 40% of the total energy consumption in the EU, energy efficiency in buildings is and continues to be an important issue. Great progress has been made in reducing the energy consumption in new buildings, but the large stock of existing buildings with poor energy performance is probably an even more crucial area of focus. This thesis deals with energy efficiency measures that can be suitable for renovation of existing houses, particularly low-temperature heating systems and ventilation systems with heat recovery. The energy performance, environmental impact and costs are evaluated for a range of system combinations, for small and large houses with various heating demands and for different climates in Europe. The results were derived through simulation with energy calculation tools. Low-temperature heating and air heat recovery were both found to be promising with regard to increasing energy efficiency in European houses. These solutions proved particularly effective in Northern Europe as low-temperature heating and air heat recovery have a greater impact in cold climates and on houses with high heating demands. The performance of heat pumps, both with outdoor air and exhaust air, was seen to improve with low-temperature heating. The choice between an exhaust air heat pump and a ventilation system with heat recovery is likely to depend on case specific conditions, but both choices are more cost-effective and have a lower environmental impact than systems without heat recovery. The advantage of the heat pump is that it can be used all year round, given that it produces DHW. Economic and environmental aspects of energy efficiency measures do not always harmonize. On the one hand, lower costs can sometimes mean larger environmental impact; on the other hand there can be divergence between different environmental aspects. This makes it difficult to define financial subsidies to promote energy efficiency measures.
Resumo:
Emissions from residential combustion appliances vary significantly depending on the firing behaviours and combustion conditions, in addition to combustion technologies and fuel quality. Although wood pellet combustion in residential heating boilers is efficient, the combustion conditions during start-up and stop phases are not optimal and produce significantly high emissions such as carbon monoxide and hydrocarbon from incomplete combustion. The emissions from the start-up and stop phases of the pellet boilers are not fully taken into account in test methods for ecolabels which primarily focus on emissions during operation on full load and part load. The objective of the thesis is to investigate the emission characteristics during realistic operation of residential wood pellet boilers in order to identify when the major part of the annual emissions occur. Emissions from four residential wood pellet boilers were measured and characterized for three operating phases (start-up, steady and stop). Emissions from realistic operation of combined solar and wood pellet heating systems was continuously measured to investigate the influence of start-up and stop phases on total annual emissions. Measured emission data from the pellet devices were used to build an emission model to predict the annual emission factors from the dynamic operation of the heating system using the simulation software TRNSYS. Start-up emissions are found to vary with ignition type, supply of air and fuel, and time to complete the phase. Stop emissions are influenced by fan operation characteristics and the cleaning routine. Start-up and stop phases under realistic operation conditions contribute 80 – 95% of annual carbon monoxide (CO) emission, 60 – 90% total hydrocarbon (TOC), 10 – 20% of nitrogen oxides (NO), and 30 – 40% particles emissions. Annual emission factors from realistic operation of tested residential heating system with a top fed wood pelt boiler can be between 190 and 400 mg/MJ for the CO emissions, between 60 and 95 mg/MJ for the NO, between 6 and 25 mg/MJ for the TOC, between 30 and 116 mg/MJ for the particulate matter and between 2x10-13 /MJ and 4x10-13 /MJ for the number of particles. If the boiler has the cleaning sequence with compressed air such as in boiler B2, annual CO emission factor can be up to 550 mg/MJ. Average CO, TOC and particles emissions under realistic annual condition were greater than the limits values of two eco labels. These results highlight the importance of start-up and stop phases in annual emission factors (especially CO and TOC). Since a large or dominating part of the annual emissions in real operation arise from the start-up and stop sequences, test methods required by the ecolabels should take these emissions into account. In this way it will encourage the boiler manufacturers to minimize annual emissions. The annual emissions of residential pellet heating system can be reduced by optimizing the number of start-ups of the pellet boiler. It is possible to reduce up to 85% of the number of start-ups by optimizing the system design and its controller such as switching of the boiler pump after it stops, using two temperature sensors for boiler ON/OFF control, optimizing of the positions of the connections to the storage tank, increasing the mixing valve temperature in the boiler circuit and decreasing the pump flow rate. For 85 % reduction of start-ups, 75 % of CO and TOC emission factors were reduced while 13% increase in NO and 15 % increase in particle emissions was observed.
Resumo:
Background There is emerging evidence that the physical environment is important for health, quality of life and care, but there is a lack of valid instruments to assess health care environments. The Sheffield Care Environment Assessment Matrix (SCEAM), developed in the United Kingdom, provides a comprehensive assessment of the physical environment of residential care facilities for older people. This paper reports on the translation and adaptation of SCEAM for use in Swedish residential care facilities for older people, including information on its validity and reliability. Methods SCEAM was translated into Swedish and back-translated into English, and assessed for its relevance by experts using content validity index (CVI) together with qualitative data. After modification, the validity assessments were repeated and followed by test-retest and inter-rater reliability tests in six units within a Swedish residential care facility that varied in terms of their environmental characteristics. Results Translation and back translation identified linguistic and semantic related issues. The results of the first content validity analysis showed that more than one third of the items had item-CVI (I-CVI) values less than the critical value of 0.78. After modifying the instrument, the second content validation analysis resulted in I-CVI scores above 0.78, the suggested criteria for excellent content validity. Test-retest reliability showed high stability (96% and 95% for two independent raters respectively), and inter-rater reliability demonstrated high levels of agreement (95% and 94% on two separate rating occasions). Kappa values were very good for test-retest (κ= 0.903 and 0.869) and inter-rater reliability (κ= 0.851 and 0.832). Conclusions Adapting an instrument to a domestic context is a complex and time-consuming process, requiring an understanding of the culture where the instrument was developed and where it is to be used. A team, including the instrument’s developers, translators, and researchers is necessary to ensure a valid translation and adaption. This study showed preliminary validity and reliability evidence for the Swedish version (S-SCEAM) when used in a Swedish context. Further, we believe that the S-SCEAM has improved compared to the original instrument and suggest that it can be used as a foundation for future developments of the SCEAM model.
Resumo:
Aims. To validate the Swedish version of the Sheffield Care Environment Assessment Matrix (S-SCEAM). The instrument’s items measure environmental elements important for supporting the needs of older people, and conceptualized within eight domains. Methods. Item relevance was assessed by a group of experts and measured using content validity index (CVI). Test-retest and inter-rater reliability tests were performed. The domain structure was assessed by the inter-rater agreement of a second group of experts, and measured using Fleiss kappa. Results. All items attained a CVI above 0.78, the suggested criteria for excellent content validity. Test-retest reliability showed high stability (96% and 95% for two independent raters respectively), and inter-rater reliability demonstrated high levels of agreement (95% and 94% on two separate rating occasions). Kappa values were very good for test-retest (κ = 0.903 and 0.869) and inter-rater reliability (κ = 0.851 and 0.832). Domain structure was good, Fleiss’ kappa was 0.63 (range 0.45 to 0.75). Conclusion. The S-SCEAM of 210 items and eight domains showed good content validity and construct validity. The instrument is suggested for use in measuring of the quality of the physical environment in residential care facilities for older persons.
Resumo:
The physical environment can influence older people’s health and well-being, and is often mentioned as being an important factor for person-centred care. Due to high levels of frail health, many older people spend a majority of their time within care facilities and depend on the physical environment for support in their daily life. However, the quality of the physical environment is rarely evaluated, and knowledge is sparse in terms of how well the environment meets the needs of older people. This is partly due to the lack of valid and reliable instruments that could provide important information on environmental quality. Aim: The aim of this thesis was to study the quality of the physical environment in Swedish care facilities for older people, and how it relates to residents’ activities and well-being. Methods: The thesis comprises four papers where both qualitative and quantitative methods were used. Study I involved the translation and adaptation of the Sheffield Care Environment Assessment Matrix (SCEAM) into a Swedish version (S-SCEAM). Several methods were used including forward and backward translation, test of validity via expert consultation and reliability tests. In Study II, S-SCEAM was used to assess the quality of the environment, and descriptive data were collected from 20 purposively sampled residential care facilities (RCFs). Study III was a comparative case study conducted at two RCFs using observations, interviews and S-SCEAM to examine how the physical environment relates to older people’s activities and interactions. In study IV, multilevel modeling was used to determine the association between the quality of the physical environment and the psychological and social well-being of older people living in RCFs. The data in the thesis were analysed using qualitative content analysis, and descriptive, bivariate and multilevel statistics. Results: A specific result was the production of the Swedish version of SCEAM. The instrument contains 210 items structured into eight domains reflecting the needs of older people. When using S-SCEAM, the results showed a substantial variation in the quality of the physical environment between and within RCFs. In general, private apartments and dining areas had high quality, whereas overall building layout and outdoor areas had lower quality. Also, older people’s safety was supported in the majority of facilities, whereas cognitive support and privacy had lower quality. Further, the results showed that environmental quality in terms of cognitive support was associated with residents’ social well-being. Specific environmental features, such as building design and space size, were also noted, through observation, as influencing residents’ activities, and several barriers were found that seemed to restrict residents’ full use of the environment. Conclusions: This thesis contributes to the growing evidence-based design field. The S-SCEAM can be used in future research on the association between the environment and people’s health and well-being. The instrument could also serve as a guide in the planning and design process of new RCFs.