4 resultados para General relativity and gravitation

em Dalarna University College Electronic Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: The overall aim of this thesis was to gain a deeper understanding of older people's view of health and care while dependent on community care. Furthermore to describe and compare formal caregivers' perceptions of quality of care, working conditions, competence, general health, and factors associated with quality of care from the caregivers' perspective. Method: Qualitative interviews were conducted with 19 older people in community care who were asked to describe what health and ill health((I), good and bad care meant for them (II). Data were analyzed using content analysis (I) and a phenomenological analysis (II). The formal caregivers; 70 nursing assistants (NAs) 163 enrolled nurses (ENs) and 198 registered nurses (RNs), answered a questionnaire consisting of five instruments: quality of care from the patient's perspective modified to formal caregivers, creative climate questionnaire, stress of conscience, health index, sense of coherence and items on education and competence (III). Statistical analyses were performed containing descriptive statistics, and comparisons between the occupational groups were made using Kruskal-Wallis ANOVA, Mann-Whitney U-test and Pearson's Chi-square test (III). Pearson's  product moment correlation analysis and multiple regression analysis were performed studying the associations between organizational climate, stress of conscience, competence, general health and sense of coherence with quality of care (IV). Results: The older people's health and well-being were related to their own ability to adapt to and compensate for their disabilities and was described as negative and positive poles of autonomy vs. dependence, togetherness vs. being an onlooker, security vs. insecurity and tranquility vs. disturbance (I).  The meaning of good care (II) was that the formal caregivers respected the older people as unique individuals, having the opportunity to live their lives as usual and receiving a safe and secure care. Good care could be experienced when the formal caregivers had adequate knowledge and competence in caring for older people, adequate time and continuity in the care organization (II). Formal caregivers reported higher perceived quality of care in the dimensions medical-technical competence and physical-technical conditions than in identity-oriented approach and socio-cultural atmosphere (III). In the organizational climate three of the dimensions were close to the value of a creative climate and in seven near a stagnant climate. The formal caregivers reported low rate of stress of conscience. The RNs reported to a higher degree than the NAs/ENs a need to gain more knowledge, but the NAs and the ENs more often received training during working hours. The RNs reported lower emotional well-being than the NAs/ENs (III). The formal caregivers' occupation, organizational climate and stress of conscience were associated with perceived quality of care (IV). Implications: The formal caregivers should have an awareness of the importance of kindness and respect, supporting the older people to retain control over their lives. The nursing managers should employ highly competent and adequate numbers of skilled formal caregivers, organize formal caregivers having round the clock continuity. Improvements of organizational climate and stress of conscience are of importance for good quality of care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electromagnetically induced transparency (EIT) is an important tool for controlling light propagation and nonlinear wave mixing in atomic gases with potential applications ranging from quantum computing to table top tests of general relativity. Here we consider EIT in an atomic Bose-Einstein condensate (BEC) trapped in a double-well potential. A weak probe laser propagates through one of the wells and interacts with atoms in a three-level Lambda configuration. The well through which the probe propagates is dressed by a strong control laser with Rabi frequency Omega(mu), as in standard EIT systems. Tunneling between the wells at the frequency g provides a coherent coupling between identical electronic states in the two wells, which leads to the formation of interwell dressed states. The macroscopic interwell coherence of the BEC wave function results in the formation of two ultranarrow absorption resonances for the probe field that are inside of the ordinary EIT transparency window. We show that these new resonances can be interpreted in terms of the interwell dressed states and the formation of a type of dark state involving the control laser and the interwell tunneling. To either side of these ultranarrow resonances there is normal dispersion with very large slope controlled by g. We discuss prospects for observing these ultranarrow resonances and the corresponding regions of high dispersion experimentally.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Exploiting solar energy technology for both heating and cooling purposes has the potential of meeting an appreciable portion of the energy demand in buildings throughout the year. By developing an integrated, multi-purpose solar energy system, that can operate all twelve months of the year, a high utilisation factor can be achieved which translates to more economical systems. However, there are still some techno-economic barriers to the general commercialisation and market penetration of such technologies. These are associated with high system and installation costs, significant system complexity, and lack of knowledge of system implementation and expected performance. A sorption heat pump module that can be integrated directly into a solar thermal collector has thus been developed in order to tackle the aforementioned market barriers. This has been designed for the development of cost-effective pre-engineered solar energy system kits that can provide both heating and cooling. This thesis summarises the characterisation studies of the operation of individual sorption modules, sorption module integrated solar collectors and a full solar heating and cooling system employing sorption module integrated collectors. Key performance indicators for the individual sorption modules showed cooling delivery for 6 hours at an average power of 40 W and a temperature lift of 21°C. Upon integration of the sorption modules into a solar collector, measured solar radiation energy to cooling energy conversion efficiencies (solar cooling COP) were between 0.10 and 0.25 with average cooling powers between 90 and 200 W/m2 collector aperture area. Further investigations of the sorption module integrated collectors implementation in a full solar heating and cooling system yielded electrical cooling COP ranging from 1.7 to 12.6 with an average of 10.6 for the test period. Additionally, simulations were performed to determine system energy and cost saving potential for various system sizes over a full year of operation for a 140 m2 single-family dwelling located in Madrid, Spain. Simulations yielded an annual solar fraction of 42% and potential cost savings of €386 per annum for a solar heating and cooling installation employing 20m2 of sorption integrated collectors.