4 resultados para FIELD TESTING
em Dalarna University College Electronic Archive
Resumo:
Dynamic system test methods for heating systems were developed and applied by the institutes SERC and SP from Sweden, INES from France and SPF from Switzerland already before the MacSheep project started. These test methods followed the same principle: a complete heating system including heat generators, storage, control etc., is installed on the test rig; the test rig software and hardware simulates and emulates the heat load for space heating and domestic hot water of a single family house, while the unit under test has to act autonomously to cover the heat demand during a representative test cycle. Within the work package 2 of the MacSheep project these similar but different test methods were harmonized and improved. The work undertaken includes: Harmonization of the physical boundaries of the unit under test. Harmonization of the boundary conditions of climate and load. Definition of an approach to reach identical space heat load in combination with an autonomous control of the space heat distribution by the unit under test. Derivation and validation of new six day and a twelve day test profiles for direct extrapolation of test results. The new harmonized test method combines the advantages of the different methods that existed before the MacSheep project. The new method is a benchmark test, which means that the load for space heating and domestic hot water preparation will be identical for all tested systems, and that the result is representative for the performance of the system over a whole year. Thus, no modelling and simulation of the tested system is needed in order to obtain the benchmark results for a yearly cycle. The method is thus also applicable to products for which simulation models are not available yet. Some of the advantages of the new whole system test method and performance rating compared to the testing and energy rating of single components are: Interaction between the different components of a heating system, e.g. storage, solar collector circuit, heat pump, control, etc. are included and evaluated in this test. Dynamic effects are included and influence the result just as they influence the annual performance in the field. Heat losses are influencing the results in a more realistic way, since they are evaluated under "real installed" and representative part-load conditions rather than under single component steady state conditions. The described method is also suited for the development process of new systems, where it replaces time-consuming and costly field testing with the advantage of a higher accuracy of the measured data (compared to the typically used measurement equipment in field tests) and identical, thus comparable boundary conditions. Thus, the method can be used for system optimization in the test bench under realistic operative conditions, i.e. under relevant operating environment in the lab. This report describes the physical boundaries of the tested systems, as well as the test procedures and the requirements for both the unit under test and the test facility. The new six day and twelve day test profiles are also described as are the validation results.
Resumo:
Vrmedrivna vitvaror eller HWC-maskiner som de kallas av tillverkaren vrms med varmt vatten frn en cirkulerande krets via en vrmevxlare inbyggd i maskinen, till skillnad frn konventionella maskiner som vrms med el. Denna teknik skall inte frvxlas med maskiner som r anslutna till varmvattenledningen och fylls p med varmt vatten och som drmed begrnsas till disk- och tvtt. Syftet med fjrrvrmedrivna vitvaror r allts att anvnda fjrrvrme, som har lgre kvalitet och pris n elenergi fr uppvrmning och torkning och p s stt spara el och utka fjrrvrmeunderlaget. En jmfrelse av koldioxidutslpp och primrenergianvndning mellan konventionella vitvaror och fjrrvrmedrivna vitvaror visar att bde koldioxidutslpp och primrenergianvndning blir lgre fr fjrrvrmedrivna vitvaror om biobrnsle anses koldioxidneutralt och den el som erstts r producerad i kolkraftverk eller gaskombikraftverk. Denna rapport beskriver utveckling och kommersialisering av vrmedrivna vitvaror (disk- och tvttmaskiner samt torktumlare och torkskp) och hur de kan anslutas mot fjrrvrmesystem i olika systemlsningar. Dessutom har de energimssiga och ekonomiska frutsttningarna fr tekniken underskts. Erfarenheterna frn fltprovning r dock mycket begrnsade, eftersom de byggen dr flttesterna skulle ske frsenades. Under 2013 frdigstlls ett flerbostadshus med vrmedrivna vitvaror i 160 lgenheter i Vsters. De utvecklade maskinernas vrmeanvndning som andel av total energianvndning vid 60 graders framledningstemperatur har uppmtts till ca 50 % fr diskmaskinen, 67 % fr tvttmaskinen, 80 % fr torktumlaren och 93 % fr torkskpet. I det studerade flerbostadshuset av passivhusstandard uppgr lasten frn vrmedrivna vitvaror komfortgolvvrme och handdukstorkar till upp mot 30 % av husets totala vrmeanvndning. Fr smhus r motsvarande siffra upp mot 20 %. Att anvnda fjrrvrme istllet fr elvrme till dessa installationer som normalt r elvrmda kan allts minska elbehovet betydligt i lgenergibebyggelse vilket ocks minskar bde koldioxidutslppen och primrenergianvndningen. Ekonomiska analyser har genomfrts fr tv olika systemkoncept (separat vitvarukrets och Vstersmodellen) fr nybyggda smhusomrden och flerfamiljshus dr fjrrvrme inte bara anvnds till vitvaror utan ocks till handdukstorkar och komfortgolvvrme. De ekonomiska analyserna visar att Vstersmodellen r den mest ekonomiskt intressanta systemlsningen med vrmedrivna vitvaror, handdukstork och komfortgolvvrme. I flerfamiljshus kan den vara konkurrenskraftig mot de elvrmda alternativen (konventionellt system med eldrivna vitvaror, komfortgolvvrme och handdukstorkar) om prisskillnaden mellan el och fjrrvrme r strre n 0,7 kr/kWh. En parameterstudie visar att kapitalkostnaden blir ganska hg jmfrt med energikostnaden, vilket betyder att lng livslngd och mnga cykler r viktigt fr att frbttra de ekonomiska frutsttningarna fr vrmedrivna vitvaror. Fr passiva smhus blir kostnaden fr Vstersmodellen med vrmedrivna vitvaror, handdukstork och komfortgolvvrme likvrdig med de elvrmda alternativen vid energiprisskillnader p 0,7 kr/kWh inklusive moms, medan det krvs prisskillnader p 0,9 kr/kWh inklusive moms fr normalisolerade smhusomrden. Sammanfattningsvis kan sgas att i kommuner med ett konkurrenskraftigt fjrrvrmepris finns det viss lnsamhet fr hela konceptet enligt Vstersmodellen med vrmedrivna vitvaror, komfortgolvvrme, och handdukstorkar. Om man dremot ser p konkurrensen fr enskilda vitvaror r det frmst torktumlaren som r konkurrenskraftig i bostder. Mlpriset p 1000 kr extra fr vrmedrift har inte kunnat uppns inom projektet fr diskmaskiner och tvttmaskiner. Det krvs lgre priser och lga anslutningskostnader fr att rkna hem diskmaskinen och tvttmaskinen som enskilda komponenter. Vrmedrivna tvttmaskiner och torktumlare r konkurrenskraftiga i flerfamiljstvttstugor. Speciellt i de fall dr belggningen r god och flera maskiner delar p anslutningskostnaden till fjrrvrmecentralen kan vrmedrift bli riktigt lnsam. Torkskpens konkurrenskraft har inte kunnat utvrderas, d priset nnu inte faststllts. Att anvnda VVC-systemet fr vrmedistribution till vrmedrivna vitvaror kan vara mycket intressant, men det krver att legionellaproblematiken kan lsas. I nulget finns ingen lsning som uppfyller formuleringarna i boverkets byggregler. Ett annat distributionsstt som kan vara intressant, men som inte underskts i studien r att anvnda VVC fr varmvattendistribution och en gemensam radiator- och vitvarukrets med konstant framledningstemperatur. Den aktr som frvntas ha strst ekonomiskt intresse av att tekniken implementeras r sannolikt fjrrvrmebolagen som fr slja mer vrme och det ligger drmed frmst p deras ansvar att marknadsfra tekniken i mtet med sina kunder.
Resumo:
Anvndandet av mobila applikationer har vxt radikalt de senaste ren och de samverkar med mnga system. Drfr stlls det hgre krav p kvaliteten och att applikationen ska anpassas till mnga olika enheter, operativsystem samt plattformar. Detta gr att test av mobila applikationer blivit viktigare och strre. Detta arbete har bedrivits som en jmfrande fallstudie inom omrdet test av mobila applikationer samt testverktyg. Syftet har varit att beskriva hur testning av mobila applikationer sker idag vilket gjorts genom litteraturstudier och intervjuer med IT-fretag. Ett annat syfte har varit att utvrdera fyra testverktyg, deras fr- och nackdelar samt hur de kan anvndas vid testning av mobila applikationer och jmfras mot manuell testning utan testverktyg. Detta har gjorts genom att skapa frstahandserfarenheter baserat p anvndandet av testverktygen. Under arbetet har vi utgtt frn mobila applikationer som vi ftt tillgng till av Triona, som varit vr samarbetspartner.Idag finns mnga olika testverktyg som kan anvndas som std fr testningen men f fretag har implementerat ngot eftersom det krver bde tid och kompetens samt valet av testverktyg kan vara svrt. Testverktygen har olika fr- och nackdelar vilket gr att de passar olika bra beroende p typ av projekt och applikation. Frdelar med att anvnda testverktyg r mjligheten att kunna automatisera, testa p flera enheter samtidigt samt f tillgng till enheter via molnet. Utmaningarna r att det kan vara svrt att installera och lra sig testverktyget samt att licenserna kan vara dyra. Det r drfr viktigt att redan innan implementationen veta vilka tester och applikationer testverktygen ska anvndas till samt vem som ska anvnda det. Utifrn vr studie kan slutsatsen dras att inget testverktyg r helt komplett men de kan bidra med olika funktioner vilket effektiviserar delar av testningen av mobila applikationer.
Resumo:
Objective: For the evaluation of the energetic performance of combined renewable heating systems that supply space heat and domestic hot water for single family houses, dynamic behaviour, component interactions, and control of the system play a crucial role and should be included in test methods. Methods: New dynamic whole system test methods were developed based on hardware in the loop concepts. Three similar approaches are described and their differences are discussed. The methods were applied for testing solar thermal systems in combination with fossil fuel boilers (heating oil and natural gas), biomass boilers, and/or heat pumps. Results: All three methods were able to show the performance of combined heating systems under transient operating conditions. The methods often detected unexpected behaviour of the tested system that cannot be detected based on steady state performance tests that are usually applied to single components. Conclusion: Further work will be needed to harmonize the different test methods in order to reach comparable results between the different laboratories. Practice implications: A harmonized approach for whole system tests may lead to new test standards and improve the accuracy of performance prediction as well as reduce the need for field tests.