4 resultados para Expansion strategy of multinational enterprise

em Dalarna University College Electronic Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Research question – The research question, that this study attempts to answer, is, what and why grocery retailers, which specifically work with the strategy of standardization, adapt in their marketing mix to the host market. Main adaptations are analyzed with regard to psychic distance in terms of consumer characteristics. Methodology – This study presents a qualitative research design. Secondary data, in-depth interviews and personal observations were used, in order to identify adaptations, which were conducted in a grocery retailer in Germany, which is its home market, and in Sweden, which is considered to be a host market. Findings – The main findings of this research indicate that grocery retailers that specifically work with the strategy of standardization, adopt their core strategy at the host market, in order to keep their economy of scale. However, the standardization strategy may cause negative financial results, which is why adaptations, in order to attract new customers, are required. Conclusively, a mix of both, the adaptation and standardization marketing strategy, has to be utilized.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Within the frame of the project REBUS, "Competitive solar heating systems for residential buildings", which is financed by Nordic Energy Research, a new type of compact solar combisystem with high degree of prefabrication was developed. A hydraulic and control concept was designed with the goal to get highest system efficiency for use with either a condensing natural gas boiler or a pellet boiler. Especially when using the potential of high peak power of modern condensing natural gas boilers, a new operation strategy of a natural gas boiler/solar combisystem can increase the energy savings of a small solar combisystem by about 80% compared to conventional operation strategies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hybrid Photovoltaic Thermal (PVT) collectors are an emerging technology that combines PV and solar thermal systems in a single solar collector producing heat and electricity simultaneously. The focus of this thesis work is to evaluate the performance of unglazed open loop PVT air system integrated on a garage roof in Borlänge. As it is thought to have a significant potential for preheating ventilation of the building and improving the PV modules electrical efficiency. The performance evaluation is important to optimize the cooling strategy of the collector in order to enhance its electrical efficiency and maximize the production of thermal energy. The evaluation process involves monitoring the electrical and thermal energies for a certain period of time and investigating the cooling effect on the performance through controlling the air mass flow provided by a variable speed fan connected to the collector by an air distribution duct. The distribution duct transfers the heated outlet air from the collector to inside the building. The PVT air collector consists of 34 Solibro CIGS type PV modules (115 Wp for each module) which are roof integrated and have replaced the traditional roof material. The collector is oriented toward the south-west with a tilt of 29 ᵒ. The collector consists of 17 parallel air ducts formed between the PV modules and the insulated roof surface. Each air duct has a depth of 0.05 m, length of 2.38 m and width of 2.38 m. The air ducts are connected to each other through holes. The monitoring system is based on using T-type thermocouples to measure the relevant temperatures, air sensor to measure the air mass flow. These parameters are needed to calculate the thermal energy. The monitoring system contains also voltage dividers to measure the PV modules voltage and shunt resistance to measure the PV current, and AC energy meters which are needed to calculate the produced electrical energy. All signals recorded from the thermocouples, voltage dividers and shunt resistances are connected to data loggers. The strategy of cooling in this work was based on switching the fan on, only when the difference between the air duct temperature (under the middle of top of PV column) and the room temperature becomes higher than 5 °C. This strategy was effective in term of avoiding high electrical consumption by the fan, and it is recommended for further development. The temperature difference of 5 °C is the minimum value to compensate the heat losses in the collecting duct and distribution duct. The PVT air collector has an area of (Ac=32 m2), and air mass flow of 0.002 kg/s m2. The nominal output power of the collector is 4 kWppv (34 CIGS modules with 115 Wppvfor each module). The collector produces thermal output energy of 6.88 kWth/day (0.21 kWth/m2 day) and an electrical output energy of 13.46 kWhel/day (0.42 kWhel/m2 day) with cooling case. The PVT air collector has a daily thermal energy yield of 1.72 kWhth/kWppv, and a daily PV electrical energy yield of 3.36 kWhel /kWppv. The fan energy requirement in this case was 0.18 kWh/day which is very small compared to the electrical energy generated by the PV collector. The obtained thermal efficiency was 8 % which is small compared to the results reported in literature for PVT air collectors. The small thermal efficiency was due to small operating air mass flow. Therefore, the study suggests increasing the air mass flow by a factor of 25. The electrical efficiency was fluctuating around 14 %, which is higher than the theoretical efficiency of the PV modules, and this discrepancy was due to the poor method of recording the solar irradiance in the location. Due to shading effect, it was better to use more than one pyranometer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The White Ribbon Alliance for safe motherhood believes respectful maternity care is the universal right of every childbearing woman. Methods: NHRC in 2012 approved an inquiry of respectful care at facility-based childbirth. Individual-, focus group interviews and content analysis was used for gathering and analysis of data. Findings: The participating women and the SBAs shared similar views, and this was that together the SBAs and relatives ensured the women remained within the comfort and safety zone when giving birth in a tertiary level maternity unit. Conclusion: The SBAs strategy of having relatives provides basic care alongside the provision of medical care by the SBAs is a strategy that Nepal could use to improve the quality of its maternity care without any additional costs. Clinical implication: Prenatal classes might contribute to preparing relatives. Further Research: Further research could evaluate such a strategy in order to determine its effectiveness in reduction of morbidity and mortality.