7 resultados para Exhaust Pipe

em Dalarna University College Electronic Archive


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report describes the work done creating a computer model of a kombi tank from Consolar. The model was created with Presim/Trnsys and Fittrn and DF were used to identify the parameters. Measurements were carried out and were used to identify the values of the parameters in the model. The identifications were first done for every circuit separately. After that, all parameters are normally identified together using all the measurements. Finally the model should be compared with other measurements, preferable realistic ones. The two last steps have not yet been carried out, because of problems finding a good model for the domestic hot water circuit.The model of the domestic hot water circuit give relatively good results for low flows at 5 l/min, but is not good for higher flows. In the report suggestions for improving the model are given. However, there was not enough time to test this within the project as much time was spent trying to solve problems with the model crashing. Suggestions for improving the model for the domestic circuit are given in chapter 4.4. The improved equations that are to be used in the improved model are given by equation 4.18, 4.19 and 4.22.Also for the boiler circuit and the solar circuit there are improvements that can be done. The model presented here has a few shortcomings, but with some extra work, an improved model can be created. In the attachment (Bilaga 1) is a description of the used model and all the identified parameters.A qualitative assessment of the store was also performed based on the measurements and the modelling carried out. The following summary of this can be given: Hot Water PreparationThe principle for controlling the flow on the primary side seems to work well in order to achieve good stratification. Temperatures in the bottom of the store after a short use of hot water, at a coldwater temperature of 12°C, was around 28-30°C. This was almost independent of the temperature in the store and the DHW-flow.The measured UA-values of the heat exchangers are not very reliable, but indicates that the heat transfer rates are much better than for the Conus 500, and in the same range as for other stores tested at SERC.The function of the mixing valve is not perfect (see diagram 4.3, where Tout1 is the outlet hot water temperature, and Tdhwo and Tdhw1 is the inlet temperature to the hot and cold side of the valve respectively). The outlet temperature varies a lot with different temperatures in the storage and is going down from 61°C to 47°C before the cold port is fully closed. This gives a problem to find a suitable temperature setting and gives also a risk that the auxiliary heating is increased instead of the set temperature of the valve, when the hot water temperature is to low.Collector circuitThe UA-value of the collector heat exchanger is much higher than the value for Conus 500, and in the same range as the heat exchangers in other stores tested at SERC.Boiler circuitThe valve in the boiler circuit is used to supply water from the boiler at two different heights, depending on the temperature of the water. At temperatures from the boiler above 58.2°C, all the water is injected to the upper inlet. At temperatures below 53.9°C all the water is injected to the lower inlet. At 56°C the water flow is equally divided between the two inlets. Detailed studies of the behaviour at the upper inlet shows that better accuracy of the model would have been achieved using three double ports in the model instead of two. The shape of the upper inlet makes turbulence, that could be modelled using two different inlets. Heat lossesThe heat losses per m3 are much smaller for the Solus 1050, than for the Conus 500 Storage. However, they are higher than those for some good stores tested at SERC. The pipes that are penetrating the insulation give air leakage and cold bridges, which could be a major part of the losses from the storage. The identified losses from the bottom of the storage are exceptionally high, but have less importance for the heat losses, due to the lower temperatures in the bottom. High losses from the bottom can be caused by air leakage through the insulation at the pipe connections of the storage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Högskolan Dalarna har i samarbete med Naturbränsle i Mellansverige AB genomfört studier på ett nytt fordon för transport av skogsflis. Fordonet är försett med egen lastningsutrustning (kran och skopa), vilket innebär att flisskördaren kan tippa flisen direkt på marken eller på en i förväg utlagd duk (minskar risken för föroreningar i samband med lastning). Studier har också genomförts på transport av flis med lastväxlarfordon och container (traditionell metod) för att jämförelser skall kunna göras mellan de olika fordonstyperna. Studierna har finansie¬rats via anslag från Statens Energimyndighet och via ”naturabidrag” från deltagande företag.Studierna visar att det nya transportfordonet är ett bättre alternativ än de traditionella last¬växlarfordonen på större objekt med långa transportavstånd. Dessutom pekar studien på att det är sannolikt är bättre även på små objekt under förutsättning att flisningskostnaden kan hållas på en rimlig nivå. Studierna visar också att det bör finnas en viss utvecklingspotential på det nya fordonet (teknik- och metodutveckling), varför det bedöms kunna konkurrera med lastväxlarfordonen även på andra typer av objekt.Jämfört med de traditionella lastväxlarfordonen har det nya fordonet bl.a. följande fördelar:•Transportarbetet blir lättare att planera i och med att beroendeförhållandet mellan in¬blandade maskiner och fordon för flisproduktion och transport upphör.••Risken för störningar i transportflödet minskar.•Miljövinsterna blir större jämfört med lastväxlarfordon som måste ställa ut tomma con¬tainrar innan flisningen kan påbörjas.•Det finns inget behov av lastmaskiner på terminalerna.•Flis kan mellanlagras i skogen.Till nackdelarna med det nya fordonet hör bl.a. följande:•Framkomligheten är något sämre än för lastväxlarfordon på mycket smala och kurviga skogsbilvägar.•Det finns en viss risk för att föroreningar följer med vid lastning av fordonet. Studies were carried out on a new vehicle for transport of fuel chips from the forest. The vehicle was equipped with a crane and a bucket meaning that the chipper may tip the fuel chips right on the ground or on a mat (vira from wood processing industry) to prevent from dirt such as sand and stones when loading. Studies were also carried out on traditional main hauling with transport bins. Transport speed was the same for all vehicles except for the new self-loader on forest roads with lower quality.The studies show that the new system probably is a better alternative on large sites with long transport distances and on sites with only little parking place for transport bins. It is also likely that the new vehicle may be used on very small sites if they are close to each other and if moving cost for the chipper is low.The studies show that the new vehicle has the following advantages:•Transport and other work may be planned in a better way leading to that stress de¬creases.•Dependence between chipper operators and truck drivers decreases.•The risk for disturbances in transport flow decreases.•Environment benefits compared to traditional system with higher traffic intensity (less exhaust gases and lower stress on roads and bridges).•No need for loading machines on terminals.•Easier to store fuel chips on landing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The demand for cooling and air-conditioning of building is increasingly ever growing. This increase is mostly due to population and economic growth in developing countries, and also desire for a higher quality of thermal comfort. Increase in the use of conventional cooling systems results in larger carbon footprint and more greenhouse gases considering their higher electricity consumption, and it occasionally creates peaks in electricity demand from power supply grid. Solar energy as a renewable energy source is an alternative to drive the cooling machines since the cooling load is generally high when solar radiation is high. This thesis examines the performance of PV/T solar collector manufactured by Solarus company in a solar cooling system for an office building in Dubai, New Delhi, Los Angeles and Cape Town. The study is carried out by analyzing climate data and the requirements for thermal comfort in office buildings. Cooling systems strongly depend on weather conditions and local climate. Cooling load of buildings depend on many parameters such as ambient temperature, indoor comfort temperature, solar gain to the building and internal gains including; number of occupant and electrical devices. The simulations were carried out by selecting a suitable thermally driven chiller and modeling it with PV/T solar collector in Polysun software. Fractional primary energy saving and solar fraction were introduced as key figures of the project to evaluate the performance of cooling system. Several parametric studies and simulations were determined according to PV/T aperture area and hot water storage tank volume. The fractional primary energy saving analysis revealed that thermally driven chillers, particularly adsorption chillers are not suitable to be utilizing in small size of solar cooling systems in hot and tropic climates such as Dubai and New Delhi. Adsorption chillers require more thermal energy to meet the cooling load in hot and dry climates. The adsorption chillers operate in their full capacity and in higher coefficient of performance when they run in a moderate climate since they can properly reject the exhaust heat. The simulation results also indicated that PV/T solar collector have higher efficiency in warmer climates, however it requires a larger size of PV/T collectors to supply the thermally driven chillers for providing cooling in hot climates. Therefore using an electrical chiller as backup gives much better results in terms of primary energy savings, since PV/T electrical production also can be used for backup electrical chiller in a net metering mechanism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

I detta examensarbete undersöktes möjligheten att installera värmeåtervinningssystem för ett flerfamiljehus i Hovgården som ligger en bit utanför Borlänge. I rapporten redovisas två olika sätt för energibesparingar som är aktuella för att ersätta borttagning av oljepannan som används i huset i dag. En rad svårigheter dök upp under undersökningen för installation av nytt värmesystem. Lämpliga lösningar kunde hittas efter mycket analys. Syftet med rapporten var att undersöka möjligheten och lönsamheten för installation av något av följande system; FVP eller VBX-modul som kan återvinna värme ur frånluften. Undersökningen visade att varken VBX eller FVP kan ersätta oljepannans värmeavgivning på ett tillfredsställande sätt. Med VBX ökas COP från 2,8 till 3,11 vilket leder till 17 MWh/år elbesparing. Däremot FVP kan försörja huset med 59 MWh/år men kan inte täcka effektbehovet för gården under kallaste dagarna. Resultatet blev att de båda undersökta systemen inte har möjlighet att ersätta oljeeldning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A ventilation radiator is a combined ventilation and heat emission unit currently of interest due to its potential for increasing energy efficiency in exhaust ventilated buildings with warm water heating. This paper presents results of performance tests of several ventilation radiator models conducted under controlled laboratory conditions.   The purpose of the study was to validate results achieved by Computational Fluid Dynamics (CFD) in an earlier study and indentify possible improvements in the performance of such systems. The main focus was on heat transfer from internal convection fins, but comfort and health aspects related to ventilation rates and air temperatures were also considered.   The general results from the CFD simulations were confirmed; the heat output of ventilation radiators may be improved by at least 20 % without sacrificing ventilation efficiency or thermal comfort.   Improved thermal efficiency of ventilation radiators allows a lower supply water temperature and energy savings both for heating up and distribution of warm water in heat pumps or district heating systems. A secondary benefit is that a high ventilation rate can be maintained all year around without risk for cold draught.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper studies the influence of hydraulics and control of thermal storage in systems combined with solar thermal and heat pump for the production of warm water and space heating in dwellings. A reference air source heat pump system with flat plate collectors connected to a combistore was defined and modeled together with the IEA SHC Task 44 / HPP Annex 38 (T44A38) “Solar and Heat Pump Systems” boundary conditions of Strasbourg climate and SFH45 building. Three and four pipe connections as well as use of internal and external heat exchangers for DHW preparation were investigated as well as sensor height for charging of the DHW zone in the store. The temperature in this zone was varied to ensure the same DHW comfort was achieved in all cases. The results show that the four pipe connection results in 9% improvement in SPF compared to three pipe and that the external heat exchanger for DHW preparation leads to a 2% improvement compared to the reference case. Additionally the sensor height for charging the DHW zone of the store should not be too low, otherwise system performance is adversely affected

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the building sector accounting for around 40% of the total energy consumption in the EU, energy efficiency in buildings is and continues to be an important issue. Great progress has been made in reducing the energy consumption in new buildings, but the large stock of existing buildings with poor energy performance is probably an even more crucial area of focus. This thesis deals with energy efficiency measures that can be suitable for renovation of existing houses, particularly low-temperature heating systems and ventilation systems with heat recovery. The energy performance, environmental impact and costs are evaluated for a range of system combinations, for small and large houses with various heating demands and for different climates in Europe. The results were derived through simulation with energy calculation tools. Low-temperature heating and air heat recovery were both found to be promising with regard to increasing energy efficiency in European houses. These solutions proved particularly effective in Northern Europe as low-temperature heating and air heat recovery have a greater impact in cold climates and on houses with high heating demands. The performance of heat pumps, both with outdoor air and exhaust air, was seen to improve with low-temperature heating. The choice between an exhaust air heat pump and a ventilation system with heat recovery is likely to depend on case specific conditions, but both choices are more cost-effective and have a lower environmental impact than systems without heat recovery. The advantage of the heat pump is that it can be used all year round, given that it produces DHW. Economic and environmental aspects of energy efficiency measures do not always harmonize. On the one hand, lower costs can sometimes mean larger environmental impact; on the other hand there can be divergence between different environmental aspects. This makes it difficult to define financial subsidies to promote energy efficiency measures.