Resumo:
Test is an area in system development. Test can be performed manually or automated. Test activities can be supported by Word documents and Excel sheets for documenting and executing test cases and as well for follow up, but there are also new test tools designed to support and facilitate the testing process and the activities of the test. This study has described manual test and identified strengths and weaknesses of manual testing with a testing tool called Microsoft Test Manager (MTM) and of manual testing using test cases and test log templates developed by the testers at Sogeti. The result that emerged from the problem and strength analysis and the analysis of literature studies and firsthand experiences (in terms of creating, documenting and executing test cases) addresses the issue of the following weaknesses and strengths. Strengths of the test tool is that it contains needed functionality all in one place and it is available when needed without having to open up other programs which saves many steps of activity. Strengths with test without the support of test tools is mainly that it is easy to learn and gives a good overview, easy to format text as desired and flexible to changes during execution of a test case. Weaknesses in test with the support of test tools include that it is difficult to get a good overview of the entire test case, that it is not possible to format the text in the test steps. It is as well not possible to modify the test steps during execution. It is also difficult to use some of the test design techniques of TMap, for example a checklist, when using the test tool MTM. Weaknesses with test without the support of the testing tool MTM is that the tester gets many more steps of activities to do compared to doing the same activities with the support of the testing tool MTM. There is more to remember because the documents the tester use are not directly linked. Altogether the strengths of the test tool stands out when it comes to supporting the testing process.
Resumo:
Palliativt förhållningssätt kännetecknas av helhetssyn av människan och uppnås genom stöttning av individen att leva med värdighet och största möjliga välbefinnande till livets slut oavsett diagnos eller ålder. Demens är en sjukdom som är svårt handikappande för den som drabbas och för de anhöriga är sjukdomen förödande. Den palliativa vården av personer med demens är inte optimerad. Studier visar att det dels beror på demenssjukdomen som är svår att vårda och dels för att stöd till de personer som vårdar sina anhöriga och det sociala kommunala nätverket har brister. Syfte: Att analysera upplevelsen av given vård i livets slutskede hos personer med demensdiagnos ur personalens och anhörigas perspektiv. Metod: Metasyntes utförd med Howell Major och Savin-Badins analysmodell, Qualitative Research Synthesis. Resultat: Kunskap och personcentrering var de två begrepp som blev produkten av syntesen. Begreppen fungerar som motsatser, om det finns kunskap och personcentrering så finns en bra upplevelse av given vård hos personal och anhöriga och om det brister i kunskap och personcentrering blir upplevelsen sämre. Diskussion: Kunskap om demens bland personal har i syntesen visats vara en indikator för god vård vid livets slut. Utbildning i demenssjukdom bör ske kontinuerligt och på olika nivåer beroende på vilken personalkategori som utbildas. Konklusion: Palliativ vård och demens måste få utrymme i utbildningarna av all personal, från undersköterska till specialistläkare.
Resumo:
The purpose of this project is to update the tool of Network Traffic Recognition System (NTRS) which is proprietary software of Ericsson AB and Tsinghua University, and to implement the updated tool to finish SIP/VoIP traffic recognition. Basing on the original NTRS, I analyze the traffic recognition principal of NTRS, and redesign the structure and module of the tool according to characteristics of SIP/VoIP traffic, and then finally I program to achieve the upgrade. After the final test with our SIP data trace files in the updated system, a satisfactory result is derived. The result presents that our updated system holds a rate of recognition on a confident level in the SIP session recognition as well as the VoIP call recognition. In the comparison with the software of Wireshark, our updated system has a result which is extremely close to Wireshark’s output, and the working time is much less than Wireshark. In the aspect of practicability, the memory overflow problem is avoided, and the updated system can output the specific information of SIP/VoIP traffic recognition, such as SIP type, SIP state, VoIP state, etc. The upgrade fulfills the demand of this project.
Resumo:
The aim of this paper is to point out benefits as well as disadvantages associated with the use of locally available, not necessarily standardized, components in stand-alone electrical power systems at rural locations. Advantages and challenges arising when the direct involvement in design, construction and maintenance of the power system is reserved to people based in the area of implementation are discussed. The presented research is centered around one particular PV-diesel hybrid system in Tanzania; a case study in which technical and social aspects related to the particular power system are studied.
Resumo:
In this thesis the solar part of a large grid-connected photovoltaic system design has been done. The main purpose was to size and optimize the system and to present figures helping to evaluate the prospective project rationality, which can potentially be constructed on a contaminated area in Falun. The methodology consisted in PV market study and component selection, site analysis and defining suitable area for solar installation; and system configuration optimization based on PVsyst simulations and Levelized Cost of Energy calculations. The procedure was mainly divided on two parts, preliminary and detailed sizing. In the first part the objective was complex, which included the investigation of the most profitable component combination and system optimization due to tilt and row distance. It was done by simulating systems with different components and orientations, which were sized for the same 100kW inverter in order to make a fair comparison. For each simulated result a simplified LCOE calculation procedure was applied. The main results of this part show that with the price of 0.43 €/Wp thin-film modules were the most cost effective solution for the case with a great advantage over crystalline type in terms of financial attractiveness. From the results of the preliminary study it was possible to select the optimal system configuration, which was used in the detailed sizing as a starting point. In this part the PVsyst simulations were run, which included full scale system design considering near shadings created by factory buildings. Additionally, more complex procedure of LCOE calculation has been used here considered insurances, maintenance, time value of money and possible cost reduction due to the system size. Two system options were proposed in final results; both cover the same area of 66000 m2. The first one represents an ordinary South faced design with 1.1 MW nominal power, which was optimized for the highest performance. According to PVsyst simulations, this system should produce 1108 MWh/year with the initial investment of 835,000 € and 0.056 €/kWh LCOE. The second option has an alternative East-West orientation, which allows to cover 80% of occupied ground and consequently have 6.6 MW PV nominal power. The system produces 5388 MWh/year costs about 4500,000 € and delivers electricity with the same price of 0.056 €/kWh. Even though the EW solution has 20% lower specific energy production, it benefits mainly from lower relative costs for inverters, mounting and annual maintenance expenses. After analyzing the performance results, among the two alternatives none of the systems showed a clear superiority so there was no optimal system proposed. Both, South and East-West solutions have own advantages and disadvantages in terms of energy production profile, configuration, installation and maintenance. Furthermore, the uncertainty due to cost figures assumptions restricted the results veracity.
Resumo:
The demand for cooling and air-conditioning of building is increasingly ever growing. This increase is mostly due to population and economic growth in developing countries, and also desire for a higher quality of thermal comfort. Increase in the use of conventional cooling systems results in larger carbon footprint and more greenhouse gases considering their higher electricity consumption, and it occasionally creates peaks in electricity demand from power supply grid. Solar energy as a renewable energy source is an alternative to drive the cooling machines since the cooling load is generally high when solar radiation is high. This thesis examines the performance of PV/T solar collector manufactured by Solarus company in a solar cooling system for an office building in Dubai, New Delhi, Los Angeles and Cape Town. The study is carried out by analyzing climate data and the requirements for thermal comfort in office buildings. Cooling systems strongly depend on weather conditions and local climate. Cooling load of buildings depend on many parameters such as ambient temperature, indoor comfort temperature, solar gain to the building and internal gains including; number of occupant and electrical devices. The simulations were carried out by selecting a suitable thermally driven chiller and modeling it with PV/T solar collector in Polysun software. Fractional primary energy saving and solar fraction were introduced as key figures of the project to evaluate the performance of cooling system. Several parametric studies and simulations were determined according to PV/T aperture area and hot water storage tank volume. The fractional primary energy saving analysis revealed that thermally driven chillers, particularly adsorption chillers are not suitable to be utilizing in small size of solar cooling systems in hot and tropic climates such as Dubai and New Delhi. Adsorption chillers require more thermal energy to meet the cooling load in hot and dry climates. The adsorption chillers operate in their full capacity and in higher coefficient of performance when they run in a moderate climate since they can properly reject the exhaust heat. The simulation results also indicated that PV/T solar collector have higher efficiency in warmer climates, however it requires a larger size of PV/T collectors to supply the thermally driven chillers for providing cooling in hot climates. Therefore using an electrical chiller as backup gives much better results in terms of primary energy savings, since PV/T electrical production also can be used for backup electrical chiller in a net metering mechanism.