6 resultados para Electrical Development Company of Ontario, Limited.
em Dalarna University College Electronic Archive
Resumo:
The world is urbanizing rapidly with more than half of the global population now living in cities. Improving urban environments for the well-being of the increasing number of urban citizens is becoming one of the most important challenges of the 21st century. Even though it is common that city planners have visions of a ’good urban milieu’, those visions are concerning visual aesthetics or practical matters. The qualitative perspective of sound, such as sonic diversity and acoustic ecology are neglected aspects in architectural design. Urban planners and politicians are therefore largely unaware of the importance of sounds for the intrinsic quality of a place. Whenever environmental acoustics is on the agenda, the topic is noise abatement or noise legislation – a quantitative attenuation of sounds. Some architects may involve acoustical aspects in their work but sound design or acoustic design has yet to develop to a distinct discipline and be incorporated in urban planning.My aim was to investigate to what extent the urban soundscape is likely to improve if modern architectural techniques merge with principles of acoustics. This is an important, yet unexplored, research area. My study explores and analyses the acoustical aspects in urban development and includes interviews with practitioners in the field of urban acoustics, situated in New York City. My conclusion is that to achieve a better understanding of the human living conditions in mega-cities, there is a need to include sonic components into the holistic sense of urban development.
Resumo:
The paper empirically tests the relationship between earnings volatility and cost of debt with a sample of more than 77,000 Swedish limited companies over the period 2006 to 2013 observing more than 677,000 firm years. As called upon by many researchers recently that there is very limited evidence of the association between earnings volatility and cost of debt this paper contributes greatly to the existing literature of earnings quality and debt contracts, especially on the consequence of earnings quality in the debt market. Earnings volatility is a proxy used for earnings quality while cost of debt is a component of debt contract. After controlling for firms’ profitability, liquidity, solvency, cashflow volatility, accruals volatility, sales volatility, business risk, financial risk and size this paper studies the effect of earnings volatility measured by standard deviation of Earnings Before Interest, Taxes, Depreciation and Amortization (EBITDA) on Cost of Debt. Overall finding suggests that lenders in Sweden does take earnings volatility into consideration while determining cost of debt for borrowers. But a deeper analysis of various industries suggest earnings volatility is not consistently used by lenders across all the industries. Lenders in Sweden are rather more sensitive to borrowers’ financial risk across all the industries. It may also be stated that larger borrowers tend to secure loans at a lower interest rate, the results are consistent with majority of the industries. Swedish debt market appears to be well prepared for financial crises as the debt crisis seems to have no or little adverse effect borrowers’ cost of capital. This study is the only empirical evidence to study the association between earnings volatility and cost of debt. Prior indirect research suggests earnings volatility has a negative effect on cost debt (i.e. an increase in earnings volatility will increase firm’s cost of debt). Our direct evidence from the Swedish debt market is consistent for some industries including media, real estate activities, transportation & warehousing, and other consumer services.
Resumo:
Research question- This thesis investigates the determinants of capital structure of the Swedish companies. In order to do so, the two dominant theories of the corporate structure are studied and their assumptions are tested. Thus, the study researches which one of the two theories is more appealing for the Swedish market. Methodology-The study follows a purely quantitative study, by conducting an econometric analysis. The data are collected from a secondary source and more particularly the "Retriever" database, which contains financial data of the Swedish companies. Findings- The findings indicate that the determinants of the corporate structure for the Swedish market do not differ from other studies which have been conducted in other countries. However, there is a difference when it comes to tax and non-tax shields. The results suggest that in most cases the Pecking Order Theory appears to be more representative for the Swedish market, since most of the coefficient appear to be in favour of it. Moreover, the significance of the effect of the industry for the financial leverage is confirmed.
Resumo:
This paper aims to explore a Tongan notion of development –'fakalakalaka' – in light of Western notions of development. Two case studies of international development aid schemes illustrate the impact of Tongan development ideas in practice. Drawing on a number of ethnographers' work on Tonga, 'fakalakalaka' appears broader than the Western notion of development. The latter is characterised by influential ideals of controllability and industrialisation. The notion of development among Tongans, on the other hand, tends to be directed by an underlying persistence that, for instance, reflects Tongan core values regarding social organisation. The production of textile 'koloa', controlled by women, emerges as central to the accomplishment of this three-dimensional development notion of intertwined physical, mental and spiritual aspects. The importance attributed to this specific kind of textile has increased in recent years and found two additional roles, or development strategies, in Tongans' contemporary transnational world.
Resumo:
Photovoltaic Thermal/Hybrid collectors are an emerging technology that combines PV and solar thermal collectors by producing heat and electricity simultaneously. In this paper, the electrical performance evaluation of a low concentrating PVT collector was done through two testing parts: power comparison and performance ratio testing. For the performance ratio testing, it is required to identify and measure the factors affecting the performance ratio on a low concentrating PVT collector. Factors such as PV cell configuration, collector acceptance angle, flow rate, tracking the sun, temperature dependence and diffuse to irradiance ratio. Solarus low concentrating PVT collector V12 was tested at Dalarna University in Sweden using the electrical equipment at the solar laboratory. The PV testing has showed differences between the two receivers. Back2 was producing 1.8 energy output more than Back1 throughout the day. Front1 and Front2 were almost the same output performance. Performance tests showed that the cell configuration for Receiver2 with cells grouping (6- 32-32-6) has proved to have a better performance ratio when to it comes to minimizing the shading effect leading to more output power throughout the day because of lowering the mismatch losses. Different factors were measured and presented in this thesis in chapter 5. With the current design, it has been obtained a peak power at STC of 107W per receiver. The solar cells have an electrical efficiency of approximately 19% while the maximum measured electrical efficiency for the collector was approximately 18 % per active cell area, in addition to a temperature coefficient of -0.53%/ ˚C. Finally a recommendation was done to help Solarus AB to know how much the electrical performance is affected during variable ambient condition and be able to use the results for analyzing and introducing new modification if needed.
Resumo:
Hybrid Photovoltaic Thermal (PVT) collectors are an emerging technology that combines PV and solar thermal systems in a single solar collector producing heat and electricity simultaneously. The focus of this thesis work is to evaluate the performance of unglazed open loop PVT air system integrated on a garage roof in Borlänge. As it is thought to have a significant potential for preheating ventilation of the building and improving the PV modules electrical efficiency. The performance evaluation is important to optimize the cooling strategy of the collector in order to enhance its electrical efficiency and maximize the production of thermal energy. The evaluation process involves monitoring the electrical and thermal energies for a certain period of time and investigating the cooling effect on the performance through controlling the air mass flow provided by a variable speed fan connected to the collector by an air distribution duct. The distribution duct transfers the heated outlet air from the collector to inside the building. The PVT air collector consists of 34 Solibro CIGS type PV modules (115 Wp for each module) which are roof integrated and have replaced the traditional roof material. The collector is oriented toward the south-west with a tilt of 29 ᵒ. The collector consists of 17 parallel air ducts formed between the PV modules and the insulated roof surface. Each air duct has a depth of 0.05 m, length of 2.38 m and width of 2.38 m. The air ducts are connected to each other through holes. The monitoring system is based on using T-type thermocouples to measure the relevant temperatures, air sensor to measure the air mass flow. These parameters are needed to calculate the thermal energy. The monitoring system contains also voltage dividers to measure the PV modules voltage and shunt resistance to measure the PV current, and AC energy meters which are needed to calculate the produced electrical energy. All signals recorded from the thermocouples, voltage dividers and shunt resistances are connected to data loggers. The strategy of cooling in this work was based on switching the fan on, only when the difference between the air duct temperature (under the middle of top of PV column) and the room temperature becomes higher than 5 °C. This strategy was effective in term of avoiding high electrical consumption by the fan, and it is recommended for further development. The temperature difference of 5 °C is the minimum value to compensate the heat losses in the collecting duct and distribution duct. The PVT air collector has an area of (Ac=32 m2), and air mass flow of 0.002 kg/s m2. The nominal output power of the collector is 4 kWppv (34 CIGS modules with 115 Wppvfor each module). The collector produces thermal output energy of 6.88 kWth/day (0.21 kWth/m2 day) and an electrical output energy of 13.46 kWhel/day (0.42 kWhel/m2 day) with cooling case. The PVT air collector has a daily thermal energy yield of 1.72 kWhth/kWppv, and a daily PV electrical energy yield of 3.36 kWhel /kWppv. The fan energy requirement in this case was 0.18 kWh/day which is very small compared to the electrical energy generated by the PV collector. The obtained thermal efficiency was 8 % which is small compared to the results reported in literature for PVT air collectors. The small thermal efficiency was due to small operating air mass flow. Therefore, the study suggests increasing the air mass flow by a factor of 25. The electrical efficiency was fluctuating around 14 %, which is higher than the theoretical efficiency of the PV modules, and this discrepancy was due to the poor method of recording the solar irradiance in the location. Due to shading effect, it was better to use more than one pyranometer.