6 resultados para Derivación nominal
em Dalarna University College Electronic Archive
Resumo:
The occurrence of pauses and hesitations in spontaneous speech has been shown to occur systematically, for example, "between sentences, after discourse markers and conjunctions and before accented content words." (Hansson [15]) This is certainly plausible in English, where pauses and hesitations can and often do occur before content words such as nominals, for example, "uh, there's a … man." (Chafe [8]) However, if hesitations are, in fact, evidence of "deciding what to talk about next," (Chafe [8]) then the complex grammatical system of German should render this pausing position precarious, since pre-modifiers must account for the gender of the nominals they modify.In this paper, I present data to test the hypothesis that pre-nominal hesitation patterns in German are dissimilar to those in English. Hesitations in German will be shown, in fact, to occur within noun phrase units. Nevertheless, native speakers most often succeed in supplying a nominal which conforms to the gender indicated by the determiner or pre-modifier. Corrections, or repairs, of infelicitous pre-modifiers indicate that the speaker was unable to supply a nominal of the same gender which the choice of pre-modifier had committed him/her to. The frequency of such repairs is shown to vary according to task, with fewest repairs occurring in elicited speech which allows for linguistic freedom and therefore is most like spontaneous speech. The data sets indicate that among German native speakers, hesitations occurring before noun phrase units (pre-NPU hesitations) indicate deliberation of what to say, while hesitations within or before the head of the noun phrase (pre-NPH hesitations) indicate deliberation of how to say what has already been decided (cf. Chafe [8]).
Resumo:
The aim of this study was to investigate how electricallyheated houses can be converted to using wood pellet and solarheating. There are a large number of wood pellet stoves on themarket. Many stoves have a water jacket, which gives anopportunity to distribute the heat to domestic hot water and aradiator heating system. Three typical Swedish houses with electric resistanceheating have been studied. Fourteen different system conceptsusing wood pellet stoves and solar heating systems have beenevaluated. The systems and the houses have been simulated indetail using TRNSYS. The houses have been divided in up to 10different zones and heat transfer by air circulation throughdoorways and open doors have been simulated. The pellet stoveswere simulated using a recently developed TRNSYS component,which models the start- and stop phases, emissions and thedynamic behaviour of the stoves. The model also calculates theCO-emissions. Simulations were made with one stove without awater jacket and two stoves with different fractions of thegenerated heat distributed in the water circuit. Simulations show that the electricity savings using a pelletstove are greatly affected by the house plan, the systemchoice, if the internal doors are open or closed and thedesired level of comfort. Installing a stove with awater-jacket connected to a radiator system and a hot waterstorage has the advantage that heat can be transferred todomestic hot water and be distributed to other rooms. Suchsystems lead to greater electricity savings, especially inhouses having a traditional layout. It was found that not allrooms needed radiators and that it was more effective in mostcases t use a stove with a higher fraction of the heatdistributed by the water circuit. The economic investigation shows that installing a woodpellet stove without a water jacket gives the lowest totalenergy- and capital costs in the house with an open plan (fortoday's energy prices and the simulated comfort criteria). Inthe houses with a traditional layout a pellet stove givesslightly higher costs than the reference house having onlyelectrical resistance heating due to the fact that less heatingcan be replaced. The concepts including stoves with a waterjacket all give higher costs than the reference system, but theconcept closest to be economical is a system with a bufferstore, a stove with a high fraction of the heat distributed bythe water circuit, a new water radiator heating system and asolar collector. Losses from stoves can be divided into: flue gas lossesincluding leakage air flow when the stove is not in operation;losses during start and stop phases; and losses due to a highair factor. An increased efficiency of the stoves is importantboth from a private economical point of view, but also from theperspective that there can be a lack of bio fuel in the nearfuture also in Sweden. From this point of view it is alsoimportant to utilize as much solar heat as possible. Theutilization of solar heat is low in the simulated systems,depending on the lack of space for a large buffer store. The simulations have shown that the annual efficiency ismuch lower that the nominal efficiency at full power. Thesimulations have also shown that changing the control principlefor the stove can improve efficiency and reduce theCO-emissions. Today's most common control principle for stovesis the on/off control, which results in many starts and stopsand thereby high CO-emissions. A more advanced control varyingthe heating rate from maximum to minimum to keep a constantroom temperature reduces the number of starts and stops andthereby the emissions. Also the efficiency can be higher withsuch a control, and the room temperature will be kept at a moreconstant temperature providing a higher comfort.
Resumo:
The overall purpose of this study is to gain knowledge about dialogues in the setting of the preschool. The more in-depth purpose is to highlight what happens in dialogues between a teacher and a child when more children join the situation of interaction in which the dialogue is taking place. A further purpose is to attempt to understand what it is that influences change in the dialogue and what significance the actions of the teacher can have for this change. The study is based on several questions that concern interaction in preschools, who it is that initiates an increase in the number of participants in those situations that involve dialogue, and what happens with the dialogue when more children join and what causes the change in the dialogue. The study is based on video observations from a preschool; approximately 10 teachers and 50 children between the ages of one and six took part in the study. The situations that were observed and documented in video format were everyday activities (both indoor and outdoor) that were led at a nominal level by teachers. In total, 40 films were recorded. Film length was between one and 60 minutes. In 32 of the films, there was interaction between a teacher and several children, and 18 of these included dialogues between a teacher and several children. Dialogue is here given a specific significance and refers to the interaction that can be described in terms of presence, listening, reciprocity, and extending. This definition of dialogue derives from a combination of Martin Buber’s philosophy of dialogue and aspects of interaction that earlier research found to be significant for children’s learning. In two of the 18 films that showed dialogue, no other children became part of the situation of interaction; the remaining 16 films were transcribed; and both verbal and non-verbal events were made apparent in the transcriptions. Analyses of the recorded material and of the transcriptions were conducted using analytical terms borrowed from conversation analysis as well as the central term for this study dialogue. The results demonstrate a complex practice and also demonstrate that dialogues in the sense given in this study take place between children and teachers. Situations of interaction also occur where dialogues take place in which a number of children join. It can be the child joining the situation of interaction who takes the initiative to an increased number of participants; however, it can also be the teacher or the child in the dialogue. The initial address can take place during a moment of transition in the interaction or at the same time as another participant is talking. The dialogue often changes when more children join the situation where the dialogue is taking place. The dialogue can end completely or be interrupted and resume. The results further demonstrate that the dialogue can continue without seemingly being affected by the fact that more children join. This happens when the child joining and the teacher in the dialogue interact in a non-verbal manner at the same time as the teacher is talking with the child in the dialogue. The dialogue can also be continued with more participants. Who takes the initiative, how the initial address occurs, and which content is given focus by the different participants are all factors that seem to affect what happens to the dialogue. How the teacher acts when more children join also appears to be significant in terms of what happens with the dialogue when more children join. In those situations where the teacher begins talking with a number of children about different subjects, the interaction ceases to be dialogic. When the teacher asks the joining child to wait, the dialogue is both interrupted and resumed, and on those occasions when the dialogue continues with more participants, the teacher listens to the joining child and the participants take turns speaking.
Resumo:
This study investigates variable noun phrase number agreement (VNA) in two second language varieties of Portuguese, spoken in Maputo, Mozambique and in Mindelo, Cape Verde. Quantitative VARBRUL analysis is carried out based on recordings made in Maputo and Mindelo 2007 and 2008. Previous quantitative studies on VNA in varieties of Brazilian Portuguese (Guy, 1981; Lopes, 2001; Andrade, 2003) as well as on VNA in first and second language varieties of Portuguese from São Tomé (Baxter, 2004; Figueiredo, 2008, 2010) indicate contact between Portuguese and African languages as the main origin of this phenomenon. VNA in Brazilian Portuguese is, however, interpreted by Scherre (1988) and Naro & Scherre (1993, 2007) as the result of language internal drift. Varieties of Portuguese from Mozambique and Cape Verde are particularly interesting to contrast in order to investigate influences from African languages on VNA, as in Mozambique Bantu languages are first languages of the vast majority of Portuguese speakers, whereas in Cape Verde, practically all Portuguese speakers are first language speakers of Cape Verdean Creole, whose substrates are West African, and not Bantu, languages. Comparison is also made with previous studies from Brazil and São Tomé. The results of this study comment previously postulated explanations for VNA in Portuguese in various ways. The analysis of the variables onset age and age stratum indicates that VNA in the analyzed varieties is a phenomenon linked to the acquisition of Portuguese as a second language and/or language contact rather than the result of internal drift. The fact that all the compared varieties tend to mark plural on pre-head components contradicts Bantu transfer as an explanation for this pattern, and raises the need to also consider more general explanations based on language contact. The basic structural similarity between the compared varieties suggests the existence of a grammatical restructuring continuum.
Resumo:
In this thesis the solar part of a large grid-connected photovoltaic system design has been done. The main purpose was to size and optimize the system and to present figures helping to evaluate the prospective project rationality, which can potentially be constructed on a contaminated area in Falun. The methodology consisted in PV market study and component selection, site analysis and defining suitable area for solar installation; and system configuration optimization based on PVsyst simulations and Levelized Cost of Energy calculations. The procedure was mainly divided on two parts, preliminary and detailed sizing. In the first part the objective was complex, which included the investigation of the most profitable component combination and system optimization due to tilt and row distance. It was done by simulating systems with different components and orientations, which were sized for the same 100kW inverter in order to make a fair comparison. For each simulated result a simplified LCOE calculation procedure was applied. The main results of this part show that with the price of 0.43 €/Wp thin-film modules were the most cost effective solution for the case with a great advantage over crystalline type in terms of financial attractiveness. From the results of the preliminary study it was possible to select the optimal system configuration, which was used in the detailed sizing as a starting point. In this part the PVsyst simulations were run, which included full scale system design considering near shadings created by factory buildings. Additionally, more complex procedure of LCOE calculation has been used here considered insurances, maintenance, time value of money and possible cost reduction due to the system size. Two system options were proposed in final results; both cover the same area of 66000 m2. The first one represents an ordinary South faced design with 1.1 MW nominal power, which was optimized for the highest performance. According to PVsyst simulations, this system should produce 1108 MWh/year with the initial investment of 835,000 € and 0.056 €/kWh LCOE. The second option has an alternative East-West orientation, which allows to cover 80% of occupied ground and consequently have 6.6 MW PV nominal power. The system produces 5388 MWh/year costs about 4500,000 € and delivers electricity with the same price of 0.056 €/kWh. Even though the EW solution has 20% lower specific energy production, it benefits mainly from lower relative costs for inverters, mounting and annual maintenance expenses. After analyzing the performance results, among the two alternatives none of the systems showed a clear superiority so there was no optimal system proposed. Both, South and East-West solutions have own advantages and disadvantages in terms of energy production profile, configuration, installation and maintenance. Furthermore, the uncertainty due to cost figures assumptions restricted the results veracity.
Resumo:
Hybrid Photovoltaic Thermal (PVT) collectors are an emerging technology that combines PV and solar thermal systems in a single solar collector producing heat and electricity simultaneously. The focus of this thesis work is to evaluate the performance of unglazed open loop PVT air system integrated on a garage roof in Borlänge. As it is thought to have a significant potential for preheating ventilation of the building and improving the PV modules electrical efficiency. The performance evaluation is important to optimize the cooling strategy of the collector in order to enhance its electrical efficiency and maximize the production of thermal energy. The evaluation process involves monitoring the electrical and thermal energies for a certain period of time and investigating the cooling effect on the performance through controlling the air mass flow provided by a variable speed fan connected to the collector by an air distribution duct. The distribution duct transfers the heated outlet air from the collector to inside the building. The PVT air collector consists of 34 Solibro CIGS type PV modules (115 Wp for each module) which are roof integrated and have replaced the traditional roof material. The collector is oriented toward the south-west with a tilt of 29 ᵒ. The collector consists of 17 parallel air ducts formed between the PV modules and the insulated roof surface. Each air duct has a depth of 0.05 m, length of 2.38 m and width of 2.38 m. The air ducts are connected to each other through holes. The monitoring system is based on using T-type thermocouples to measure the relevant temperatures, air sensor to measure the air mass flow. These parameters are needed to calculate the thermal energy. The monitoring system contains also voltage dividers to measure the PV modules voltage and shunt resistance to measure the PV current, and AC energy meters which are needed to calculate the produced electrical energy. All signals recorded from the thermocouples, voltage dividers and shunt resistances are connected to data loggers. The strategy of cooling in this work was based on switching the fan on, only when the difference between the air duct temperature (under the middle of top of PV column) and the room temperature becomes higher than 5 °C. This strategy was effective in term of avoiding high electrical consumption by the fan, and it is recommended for further development. The temperature difference of 5 °C is the minimum value to compensate the heat losses in the collecting duct and distribution duct. The PVT air collector has an area of (Ac=32 m2), and air mass flow of 0.002 kg/s m2. The nominal output power of the collector is 4 kWppv (34 CIGS modules with 115 Wppvfor each module). The collector produces thermal output energy of 6.88 kWth/day (0.21 kWth/m2 day) and an electrical output energy of 13.46 kWhel/day (0.42 kWhel/m2 day) with cooling case. The PVT air collector has a daily thermal energy yield of 1.72 kWhth/kWppv, and a daily PV electrical energy yield of 3.36 kWhel /kWppv. The fan energy requirement in this case was 0.18 kWh/day which is very small compared to the electrical energy generated by the PV collector. The obtained thermal efficiency was 8 % which is small compared to the results reported in literature for PVT air collectors. The small thermal efficiency was due to small operating air mass flow. Therefore, the study suggests increasing the air mass flow by a factor of 25. The electrical efficiency was fluctuating around 14 %, which is higher than the theoretical efficiency of the PV modules, and this discrepancy was due to the poor method of recording the solar irradiance in the location. Due to shading effect, it was better to use more than one pyranometer.