3 resultados para Data Coordinating Center

em Dalarna University College Electronic Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study is to evaluate the variation of solar radiation data between different data sources that will be free and available at the Solar Energy Research Center (SERC). The comparison between data sources will be carried out for two locations: Stockholm, Sweden and Athens, Greece. For the desired locations, data is gathered for different tilt angles: 0°, 30°, 45°, 60° facing south. The full dataset is available in two excel files: “Stockholm annual irradiation” and “Athens annual irradiation”. The World Radiation Data Center (WRDC) is defined as a reference for the comparison with other dtaasets, because it has the highest time span recorded for Stockholm (1964–2010) and Athens (1964–1986), in form of average monthly irradiation, expressed in kWh/m2. The indicator defined for the data comparison is the estimated standard deviation. The mean biased error (MBE) and the root mean square error (RMSE) were also used as statistical indicators for the horizontal solar irradiation data. The variation in solar irradiation data is categorized in two categories: natural or inter-annual variability, due to different data sources and lastly due to different calculation models. The inter-annual variation for Stockholm is 140.4kWh/m2 or 14.4% and 124.3kWh/m2 or 8.0% for Athens. The estimated deviation for horizontal solar irradiation is 3.7% for Stockholm and 4.4% Athens. This estimated deviation is respectively equal to 4.5% and 3.6% for Stockholm and Athens at 30° tilt, 5.2% and 4.5% at 45° tilt, 5.9% and 7.0% at 60°. NASA’s SSE, SAM and RETScreen (respectively Satel-light) exhibited the highest deviation from WRDC’s data for Stockholm (respectively Athens). The essential source for variation is notably the difference in horizontal solar irradiation. The variation increases by 1-2% per degree of tilt, using different calculation models, as used in PVSYST and Meteonorm. The location and altitude of the data source did not directly influence the variation with the WRDC data. Further examination is suggested in order to improve the methodology of selecting the location; Examining the functional dependence of ground reflected radiation with ambient temperature; variation of ambient temperature and its impact on different solar energy systems; Im pact of variation in solar irradiation and ambient temperature on system output.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to investigate electricity supply solutions for an educationalcenter that is being built in Chonyonyo Tanzania. Off-grid power generation solutions andfurther optimization possibilities were studied for the case.The study was done for Engineers Without Borders in Sweden. Who are working withMavuno Project on the educational center. The school is set to start operating in year 2015with 40 girl students in the beginning. The educational center will help to improve genderequality by offering high quality education in a safe environment for girls in rural area.It is important for the system to be economically and environmentally sustainable. Thearea has great potential for photovoltaic power generation. Thus PV was considered as theprimary power generation and a diesel generator as a reliable backup. The system sizeoptimization was done with HOMER. For the simulations HOMER required componentdata, weather data and load data. Common components were chose with standardproperties, the loads were based on load estimations from year 2011 and the weather datawas acquired from NASA database. The system size optimization result for this base casewas a system with 26 kW PW; 5.5 kW diesel generator, 15 kW converter and 112 T-105batteries. The initial cost of the system was 55 875 €, the total net present cost 92 121 €and the levelized cost of electricity 0.264 €/kWh.In addition three optimization possibilities were studied. First it was studied how thesystem should be designed and how it would affect the system size to have night loads(security lights) use DC and could the system then be extended in blocks. As a result it wasfound out that the system size could be decreased as the inverter losses would be avoided.Also the system extension in blocks was found to be possible. The second study was aboutinverter stacking where multiple inverters can work as one unit. This type of connectionallows only the required number of inverters to run while shutting down the excess ones.This would allow the converter-unit to run with higher efficiency and lower powerconsumption could be achieved. In future with higher loads the system could be easilyextendable by connecting more inverters either in parallel or series depending on what isneeded. Multiple inverters would also offer higher reliability than using one centralizedinverter. The third study examined how the choice of location for a centralized powergeneration affects the cable sizing for the system. As a result it was found that centralizedpower generation should be located close to high loads in order to avoid long runs of thickcables. Future loads should also be considered when choosing the location. For theeducational center the potential locations for centralized power generation were found outto be close to the school buildings and close to the dormitories.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Most previous studies have focused on entire trips in a geographic region, while a few of them addressed trips induced by a city landmark. Therefore paper explores trips and their CO2 emissions induced by a shopping center from a time-space perspective and their usage in relocation planning. This is conducted by the means of a case study in the city of Borlänge in mid-Sweden where trips to the city’s largest shopping mall in its center are examined. We use GPS tracking data of car trips that end and start at the shopping center. Thereafter, (1) we analyze the traffic emission patterns from a time-space perspective where temporal patterns reveal an hourly-based traffic emission dynamics and where spatial patterns uncover a heterogeneous distribution of traffic emissions in spatial areas and individual street segments. Further, (2) this study reports that most of the observed trips follow an optimal route in terms of CO2 emissions. In this respect, (3) we evaluate how well placed the current shopping center is through a comparison with two competing locations. We conclude that the two suggested locations, which are close to the current shopping center, do not show a significant improvement in term of CO2 emissions.