3 resultados para Cut-off operation
em Dalarna University College Electronic Archive
Resumo:
Background: Although associated adverse pregnancy outcomes, no international or Swedish consensus exists that identifies a cut-off value or what screening method to use for definition of gestational diabetes mellitus. This study investigates the following: i) guidelines for screening of GDM; ii) background and risk factors for GDM and selection to OGTT; and iii) pregnancy outcomes in relation to GDM, screening regimes and levels of OGTT 2 hour glucose values. Methods: This cross-sectional and population-based study uses data from the Swedish Maternal Health Care Register (MHCR) (2011 and 2012) combined with guidelines for GDM screening (2011-2012) from each Maternal Health Care Area (MHCA) in Sweden. The sample consisted of 184, 183 women: 88, 140 in 2011 and 96,043 in 2012. Chi-square and two independent samples t-tests were used. Univariate and multivariate logistic regression analyses were performed. Results: Four screening regimes of oral glucose tolerance test (OGTT) (75 g of glucose) were used: A) universal screening with a 2-hour cut-off value of 10.0 mmol/L; B) selective screening with a 2-hour cut-off value of 8.9 mmol/L; C) selective screening with a 2-hour cut-off value of 10.0 mmol/L; and D) selective screening with a 2-hour cut-off value of 12.2 mmol/L. The highest prevalence of GDM (2.9%) was found with a 2-hour cut-off value of 8.9 mmol/L when selective screening was applied. Unemployment and low educational level were associated with an increased risk of GDM. The OR was 4.14 (CI 95%: 3.81-4.50) for GDM in obese women compared to women with BMI <30 kg/m(2). Women with non-Nordic origin presented a more than doubled risk for GDM compared to women with Nordic origin (OR = 2.24; CI 95%: 2.06-2.43). Increasing OGTT values were associated with increasing risks of adverse pregnancy outcomes. Conclusions: There was no consensus regarding screening regimes for GDM from 2011 through 2012 when four different regimes were applied in Sweden. Increasing levels of OGTT 2-hour glucose values were strongly associated with adverse pregnancy outcomes. Based on these findings, we suggest that Sweden adopts the recent recommendations of the International Association of Diabetes and Pregnancy Study Group (IADPSG) concerning the performance of OGTT and the diagnostic criteria for GDM.
Resumo:
Emissions from residential combustion appliances vary significantly depending on the firing behaviours and combustion conditions, in addition to combustion technologies and fuel quality. Although wood pellet combustion in residential heating boilers is efficient, the combustion conditions during start-up and stop phases are not optimal and produce significantly high emissions such as carbon monoxide and hydrocarbon from incomplete combustion. The emissions from the start-up and stop phases of the pellet boilers are not fully taken into account in test methods for ecolabels which primarily focus on emissions during operation on full load and part load. The objective of the thesis is to investigate the emission characteristics during realistic operation of residential wood pellet boilers in order to identify when the major part of the annual emissions occur. Emissions from four residential wood pellet boilers were measured and characterized for three operating phases (start-up, steady and stop). Emissions from realistic operation of combined solar and wood pellet heating systems was continuously measured to investigate the influence of start-up and stop phases on total annual emissions. Measured emission data from the pellet devices were used to build an emission model to predict the annual emission factors from the dynamic operation of the heating system using the simulation software TRNSYS. Start-up emissions are found to vary with ignition type, supply of air and fuel, and time to complete the phase. Stop emissions are influenced by fan operation characteristics and the cleaning routine. Start-up and stop phases under realistic operation conditions contribute 80 – 95% of annual carbon monoxide (CO) emission, 60 – 90% total hydrocarbon (TOC), 10 – 20% of nitrogen oxides (NO), and 30 – 40% particles emissions. Annual emission factors from realistic operation of tested residential heating system with a top fed wood pelt boiler can be between 190 and 400 mg/MJ for the CO emissions, between 60 and 95 mg/MJ for the NO, between 6 and 25 mg/MJ for the TOC, between 30 and 116 mg/MJ for the particulate matter and between 2x10-13 /MJ and 4x10-13 /MJ for the number of particles. If the boiler has the cleaning sequence with compressed air such as in boiler B2, annual CO emission factor can be up to 550 mg/MJ. Average CO, TOC and particles emissions under realistic annual condition were greater than the limits values of two eco labels. These results highlight the importance of start-up and stop phases in annual emission factors (especially CO and TOC). Since a large or dominating part of the annual emissions in real operation arise from the start-up and stop sequences, test methods required by the ecolabels should take these emissions into account. In this way it will encourage the boiler manufacturers to minimize annual emissions. The annual emissions of residential pellet heating system can be reduced by optimizing the number of start-ups of the pellet boiler. It is possible to reduce up to 85% of the number of start-ups by optimizing the system design and its controller such as switching of the boiler pump after it stops, using two temperature sensors for boiler ON/OFF control, optimizing of the positions of the connections to the storage tank, increasing the mixing valve temperature in the boiler circuit and decreasing the pump flow rate. For 85 % reduction of start-ups, 75 % of CO and TOC emission factors were reduced while 13% increase in NO and 15 % increase in particle emissions was observed.
Resumo:
This paper elaborates the routing of cable cycle through available routes in a building in order to link a set of devices, in a most reasonable way. Despite of the similarities to other NP-hard routing problems, the only goal is not only to minimize the cost (length of the cycle) but also to increase the reliability of the path (in case of a cable cut) which is assessed by a risk factor. Since there is often a trade-off between the risk and length factors, a criterion for ranking candidates and deciding the most reasonable solution is defined. A set of techniques is proposed to perform an efficient and exact search among candidates. A novel graph is introduced to reduce the search-space, and navigate the search toward feasible and desirable solutions. Moreover, admissible heuristic length estimation helps to early detection of partial cycles which lead to unreasonable solutions. The results show that the method provides solutions which are both technically and financially reasonable. Furthermore, it is proved that the proposed techniques are very efficient in reducing the computational time of the search to a reasonable amount.