This report describes the work done creating a computer model of a kombi tank from Consolar. The model was created with Presim/Trnsys and Fittrn and DF were used to identify the parameters. Measurements were carried out and were used to identify the values of the parameters in the model. The identifications were first done for every circuit separately. After that, all parameters are normally identified together using all the measurements. Finally the model should be compared with other measurements, preferable realistic ones. The two last steps have not yet been carried out, because of problems finding a good model for the domestic hot water circuit.The model of the domestic hot water circuit give relatively good results for low flows at 5 l/min, but is not good for higher flows. In the report suggestions for improving the model are given. However, there was not enough time to test this within the project as much time was spent trying to solve problems with the model crashing. Suggestions for improving the model for the domestic circuit are given in chapter 4.4. The improved equations that are to be used in the improved model are given by equation 4.18, 4.19 and 4.22.Also for the boiler circuit and the solar circuit there are improvements that can be done. The model presented here has a few shortcomings, but with some extra work, an improved model can be created. In the attachment (Bilaga 1) is a description of the used model and all the identified parameters.A qualitative assessment of the store was also performed based on the measurements and the modelling carried out. The following summary of this can be given: Hot Water PreparationThe principle for controlling the flow on the primary side seems to work well in order to achieve good stratification. Temperatures in the bottom of the store after a short use of hot water, at a coldwater temperature of 12°C, was around 28-30°C. This was almost independent of the temperature in the store and the DHW-flow.The measured UA-values of the heat exchangers are not very reliable, but indicates that the heat transfer rates are much better than for the Conus 500, and in the same range as for other stores tested at SERC.The function of the mixing valve is not perfect (see diagram 4.3, where Tout1 is the outlet hot water temperature, and Tdhwo and Tdhw1 is the inlet temperature to the hot and cold side of the valve respectively). The outlet temperature varies a lot with different temperatures in the storage and is going down from 61°C to 47°C before the cold port is fully closed. This gives a problem to find a suitable temperature setting and gives also a risk that the auxiliary heating is increased instead of the set temperature of the valve, when the hot water temperature is to low.Collector circuitThe UA-value of the collector heat exchanger is much higher than the value for Conus 500, and in the same range as the heat exchangers in other stores tested at SERC.Boiler circuitThe valve in the boiler circuit is used to supply water from the boiler at two different heights, depending on the temperature of the water. At temperatures from the boiler above 58.2°C, all the water is injected to the upper inlet. At temperatures below 53.9°C all the water is injected to the lower inlet. At 56°C the water flow is equally divided between the two inlets. Detailed studies of the behaviour at the upper inlet shows that better accuracy of the model would have been achieved using three double ports in the model instead of two. The shape of the upper inlet makes turbulence, that could be modelled using two different inlets. Heat lossesThe heat losses per m3 are much smaller for the Solus 1050, than for the Conus 500 Storage. However, they are higher than those for some good stores tested at SERC. The pipes that are penetrating the insulation give air leakage and cold bridges, which could be a major part of the losses from the storage. The identified losses from the bottom of the storage are exceptionally high, but have less importance for the heat losses, due to the lower temperatures in the bottom. High losses from the bottom can be caused by air leakage through the insulation at the pipe connections of the storage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inom ramen för projektet Energi- och miljökompetenscentrum vid Högskolan Dalarna haren kortare förstudie kring tekniken som används av Timber Tower GmbH för högavindkrafttorn i trä gjorts. Huvudsyftet med studien har varit att titta närmare på teknikenoch dess potential för svensk landbaserad vindkraft samt utreda vad detta kan innebära förregionen.Trenden för landbaserad vindkraft i skogsmiljö går mot allt högre torn. Skogsmiljön gör attden marknära turbulensen och vindgradienten blir större än över t.ex. hav vilket gör detmer föredelaktigt att använda högre torn.Tekniken som Timber Tower GmbH använder är att bygga tornet på plats med en koniskhålstomme av plana paneler av korslimmat limträ (som annars främst används vidbyggnation av höga hus med massivträstomme). Tekniken är skyddad av ett flertalpatentansökningar varav minst en är beviljad.Vid en jämförelse mellan trätorn och svetsade ståltorn (som är den dominerandetorntekniken idag) kan det konstateras att trätornstekniken är ekonomiskt intressant.Framförallt blir trätornen mer intressanta i jämförelse med ståltornen vi ökande höjder (>100 m) pga. dess transportfördelar. Vidare bör det nämnas att de torntekniker somanvänds idag vid höjder runt 140 m och högre främst är fackverkstorn i stål ochhybridtorn med en hög bas av förspänd betong och övre delen i stål.Då ett typgodkännande av ett vindkraftverk gäller torn och turbin är det i praktiken alltidturbintillverkaren som prissätter och levererar ett komplett vindkraftverk. Medutgångspunkt i regeringens planeringsram för svensk vindkraftutbyggnad (20 TWh/årlandbaserad vindkraft 2020) kan dock marknadsvärdet för torn uppskattas till 2-3 miljarderkr/år fram till 2020. För trätorn motsvarar detta en årlig potentiell volym på ca 190 000 m3.Slutsatsen i denna korta studie är att det är tekniskt möjligt att designa ett trätorn i rimligadimensioner för en 2-3 MW turbin med navhöjd ca 140 m och att detta sannolikt även ärekonomiskt intressant. Då ett trätorn blir något lättare än motsvarande ståltorn går det åtmindre energi för att göra ett trätorn. Hur mycket mindre är dock osäkert pga. den storaspridningen i siffror för energiåtgång för stålproduktion och i praktiken blir skillnadenäven leverantörsberoende. Eftersom andelen förnyelsebar energi är betydligt större vidtillverkningen av materialet för trätornen kommer trätornet att ge en betydande sänkningpå utsläppt CO2e/kWhel jämfört med motsvarande verk med ståltorn. Ett annat argumentför trätorn är förenklade transporter jämfört med t.ex. svetsade ståltorn eller hybridtornmed prefabricerade betongelement.Om tekniken etableras kan det i förlängningen leda till en regional påverkan i form av ökatlokalt innehåll i vindkraftprojekten t.ex. genom ökade råvaruleveranser (eg. sågat ochtorkat virke), lokal produktion av korslimmat limträ eller exempelvis bildande avspecialiserade montagefirmor. Det största hindret för tekniken just nu är dessmarknadsintroduktion och acceptans samt typgodkännande tillsammans med en för svenskmarknad intressant turbinleverantör. För att få acceptans för tekniken krävs byggande ochutvärdering av minst ett verk med trätorn. En intressant storlek för marknaden är en 2-3MW turbin med navhöjd ca 140 m. Ett sådant verk skulle i så fall få det högstavindkrafttornet i Sverige och sannolikt det högsta vindkrafttornet i trä i världen. Byggandetav ett första verk med trätorn skulle sannolikt även kräva ett behov av stödfinansiering föratt täcka en projektörs ökade risk. Då flera vindkraftetableringar i regionen uppvisar godaproduktionsresultat (med Tavelberget som gott exempel) visar det att regionen ärintressant för introduktion och utvärdering av ny teknologi.