5 resultados para x-ray computed tomography

em CentAUR: Central Archive University of Reading - UK


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Micro-computed tomography (μCT) has been successfully used to study the cardiovascular system of mouse embryos in situ. With the use of barium as a suitable contrast agent, blood vessels have been imaged and analysed quantitatively such as blood volume and vessel sizes on embryos of ages 14.5 to 16.5 days old. The advantage of using this imaging modality is that it has provided three dimensional information whilst leaving samples intact for further study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ray micro-tomography is a well-established technique for non-invasive imaging and evaluation of heterogeneous materials. An inexpensive X-ray micro-tomography system has been designed and built for the specific purposes of examining root growth and root/soil interactions. The system uses a silver target X-ray source with a focal spot diameter of 80 mum, an X-ray image intensifier with a sampling aperture of about 100 mum, and a sample with a diameter of 25 mm. Pre-germinated wheat and rape seeds were grown for up to 8-10 days in plastic containers in a sandy loam soil sieved to < 250 μm, and imaged with the X-ray system at regular intervals. The quality of 3 D image obtained was good allowing the development and growth of both root axes and some first-order laterals to be observed. The satisfactory discrimination between soil and roots enabled measurements of root diameter (wheat values were 0.48-1.22 mm) in individual tomographic slices and, by tracking from slice to slice, root lengths were also measured. The measurements obtained were generally within 10% of those obtained from destructive samples measured manually and with a flat-bed scanner. Further developments of the system will allow more detailed examination of the root: soil interface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An X-ray micro-tomography system has been designed that is dedicated to the low-dose imaging of radiation sensitive living organisms and has been used to image the early development of the first few days of plant development immediately after germination. The system is based on third-generation X-ray micro-tomography system and consists of an X-ray tube, two-dimensional X-ray detector and a mechanical sample manipulation stage. The X-ray source is a 50 kVp X-ray tube with a silver target with a filter to centre the X-ray spectrum on 22 keV.A 100 mm diameter X-ray image intensifier (XRII) is used to collect the two-dimensional projection images. The rotation tomography table incorporates a linear translation mechanism to eliminate ring artefact that is commonly associated with third-generation tomography systems' Developing maize seeds (Triticum aestivum) have been imaged using the system with a cubic voxel linear dimension of 100 mum, over a diameter of 25 mm and the root lengths and volumes measured. The X-ray dose to the plants was also assessed and found to have no effect on the plant root development. (C) 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

R. Benjamin (1995) addressed the application of the “object 3D” X ray reconstruction technique for electronically “unpacking” suspect items, when screening aircraft luggage. However, there is no satisfactory solution to the mass screening of hold luggage. Computed Tomography, CT, entails excessive radiation dosages, and its rate of throughput is quite inadequate. A novel variant of “object 3D” is therefore put forward, adapting some of the technology of existing cabin luggage screening systems-but on a substantially larger scale-which does achieve the required throughput at an acceptable radiation dosage and cost.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

*** Purpose – Computer tomography (CT) for 3D reconstruction entails a huge number of coplanar fan-beam projections for each of a large number of 2D slice images, and excessive radiation intensities and dosages. For some applications its rate of throughput is also inadequate. A technique for overcoming these limitations is outlined. *** Design methodology/approach – A novel method to reconstruct 3D surface models of objects is presented, using, typically, ten, 2D projective images. These images are generated by relative motion between this set of objects and a set of ten fanbeam X-ray sources and sensors, with their viewing axes suitably distributed in 2D angular space. *** Findings – The method entails a radiation dosage several orders of magnitude lower than CT, and requires far less computational power. Experimental results are given to illustrate the capability of the technique *** Practical implications – The substantially lower cost of the method and, more particularly, its dramatically lower irradiation make it relevant to many applications precluded by current techniques *** Originality/value – The method can be used in many applications such as aircraft hold-luggage screening, 3D industrial modelling and measurement, and it should also have important applications to medical diagnosis and surgery.