91 resultados para units samples

em CentAUR: Central Archive University of Reading - UK


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper concerns the design and analysis of serial dilution assays to estimate the infectivity of a sample of tissue when it is assumed that the sample contains a finite number of indivisible infectious units such that a subsample will be infectious if it contains one or more of these units. The aim of the study is to estimate the number of infectious units in the original sample. The standard approach to the analysis of data from such a study is based on the assumption of independence of aliquots both at the same dilution level and at different dilution levels, so that the numbers of infectious units in the aliquots follow independent Poisson distributions. An alternative approach is based on calculation of the expected value of the total number of samples tested that are not infectious. We derive the likelihood for the data on the basis of the discrete number of infectious units, enabling calculation of the maximum likelihood estimate and likelihood-based confidence intervals. We use the exact probabilities that are obtained to compare the maximum likelihood estimate with those given by the other methods in terms of bias and standard error and to compare the coverage of the confidence intervals. We show that the methods have very similar properties and conclude that for practical use the method that is based on the Poisson assumption is to be recommended, since it can be implemented by using standard statistical software. Finally we consider the design of serial dilution assays, concluding that it is important that neither the dilution factor nor the number of samples that remain untested should be too large.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The levels of alignment of the mesogenic units and of the polymer backbone trajectory for polyacrylate based nematic side-chain liquid crystal polymers and elastomers were evaluated by using wide angle X-ray and small angle neutron scattering procedures. The X-ray scattering measurements show that substantial levels of preferred orientation of the mesogenic units may be introduced through magnetic fields for uncrosslinked polymers and through mechanical extension for liquid crystal elastomers. Small angle neutron scattering measurements show that for highly aligned samples an anisotropic polymer backbone trajectory is observed in which the envelope is slightly extended by ∼ 10% in the direction parallel to the axis of alignment of the mesogenic units. The sense of this coupling differs from that recorded for other uncrosslinked side-chain liquid crystal polymers. Possible mechanisms to account for this anisotropy and its relationship to the properties of liquid crystal elastomers are discussed. The observed deformation behaviour of the liquid crystal elastomer is non-affine and this appears to confirm the dominating influence of the liquid crystal order of the side chains on the mechanical properties of these novel networks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research record on the quantification of sediment transport processes in periglacial mountain environments in Scandimvia dates back to the 1950s. A wide range of measurements is. available, especially from the Karkevagge region of northern Sweden. Within this paper satellite image analysis and tools provided by geographic information systems (GIS) are exploited in order to extend and improve this research and to complement geophysical methods. The processes of interest include mass movements such as solifluction, slope wash, dirty avalanches and rock-and boulder falls. Geomorphic process units have been derived in order to allow quantification via GIS techniques at a catchment scale. Mass movement rates based on existing Field measurements are employed in the budget calculation. In the Karkevagge catch ment. 80% of the area can be identified either as a source area for sediments or as a zone where sediments are deposited. The overall budget for the slopes beneath the rockwalls in the Karkevagge is approximately 680 t a(-1) whilst about 150 : a-1 are transported into the fluvial System.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This contribution describes the optimization of chlorine extraction from silicate samples by pyrohydrolysis prior to the precise determination of Cl stable-isotope compositions (637 Cl) by gas source, dual inlet Isotope Ratio Mass Spectrometry (IRMS) on CH(3)Clg. The complete method was checked on three international reference materials for Cl-content and two laboratory glass standards. Whole procedure blanks are lower than 0. 5 mu mol, corresponding to less than 10 wt.% of most of the sample chloride analysed. In the absence of international chlorine isotope rock, we report here Cl extracted compared to accepted Cl contents and reproducibilities on Cl and delta Cl-37 measurements for the standard rocks. After extraction, the Cl contents of the three international references compared within error with the accepted values (mean yield = 94 +/-10%) with reproducibilities better than 12% (10). The laboratory glass standards - andesite SO100DS92 and phonolite S9(2) - were used specifically to test the effect of chloride amount on the measurements. They gave Cl extraction yields of 100 +/-6% (1 sigma-; n = 15) and 105 +/- 8% (1 sigma-; n = 7), respectively, with delta Cl-37 values of -0.51 0.14%o and -0.39 0.17%o (1g). In summary, for silicate samples with Cl contents between 39 and 9042 ppm, the Pyrohydrolysis/HPLC method leads to overall CI extraction yields of 100 8%, reproducibilities on Cl contents of 7% and on delta Cl-37 measurements of 0.12%o (all 1 sigma). The method was further applied to ten silicate rocks of various mineralogy and chemistry (meteorite, fresh MORB glasses, altered basalts and setpentinized peridotites) chosen for their large range of Cl contents (70-2156 ppm) and their geological significance. delta Cl-37 values range between -2.33 and -0.50%o. These strictly negative values contrast with the large range and mainly positive values previously reported for comparable silicate samples and shown here to be affected by analytical problems. Thus we propose a preliminary, revised terrestrial CI cycle, mainly dominated by negative and zero delta Cl-37 values. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The delineation of Geomorphic Process Units (GPUs) aims to quantify past, current and future geomorphological processes and the sediment flux associated with them. Five GPUs have been identified for the Okstindan area of northern Norway and these were derived from the combination of Landsat satellite imagery (TM and ETM+) with stereo aerial photographs (used to construct a Digital Elevation Model) and ground survey. The Okstindan study area is sub-arctic and mountainous and is dominated by glacial and periglacial processes. The GPUs exclude the glacial system (some 37% of the study area) and hence they are focussed upon periglacial and colluvial processes. The identified GPUs are: 1. solifluction and rill erosion; 2. talus creep, slope wash and rill erosion; 3. accumulation of debris by rock and boulder fall; 4. rockwalls; and 5. stable ground with dissolved transport. The GPUs have been applied to a ‘test site’ within the study area in order to illustrate their potential for mapping the spatial distribution of geomorphological processes. The test site within the study area is a catchment which is representative of the range of geomorphological processes identified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ochre samples excavated from the neolithic site at Qatalhoyuk, Turkey have been compared with "native" ochres from Clearwell Caves, UK using infrared spectroscopy backed up by Raman spectroscopy, scanning electron microscopy (with energy-dispersive X-rays (EDX) analysis), powder X-ray diffraction, diffuse reflection UV-Vis and atomic absorption spectroscopies. For the Clearwell Caves ochres, which range in colour from yellow-orange to red-brown, it is shown that the colour is related to the nature of the chromophore present and not to any differences in particle size. The darker red ochres contain predominantly haematite while the yellow ochre contains only goethite. The ochres from Qatalhoyuk contain only about one-twentieth of the levels of iron found in the Clearwell Caves ochres. The iron oxide pigment (haematite in all cases studied here) has been mixed with a soft lime plaster which also contains calcite and silicate (clay) minerals. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A range of archaeological samples have been examined using FT-IR spectroscopy. These include suspected coprolite samples from the Neolithic site of Catalhoyuk in Turkey, pottery samples from the Roman site of Silchester, UK and the Bronze Age site of Gatas, Spain and unidentified black residues on pottery sherds from the Roman sites of Springhead and Cambourne, UK. For coprolite samples the aim of FT-IR analysis is identification. Identification of coprolites in the field is based on their distinct orange colour; however, such visual identifications can often be misleading due to their similarity with deposits such as ochre and clay. For pottery the aim is to screen those samples that might contain high levels of organic residues which would be suitable for GC-MS analysis. The experiments have shown coprolites to have distinctive spectra, containing strong peaks from calcite, phosphate and quartz; the presence of phosphorus may be confirmed by SEM-EDX analysis. Pottery containing organic residues of plant and animal origin has also been shown to generally display strong phosphate peaks. FT-IR has distinguished between organic resin and non-organic compositions for the black residues, with differences also being seen between organic samples that have the same physical appearance. Further analysis by CC-MS has confirmed the identification of the coprolites through the presence of coprostanol and bile acids, and shows that the majority of organic pottery residues are either fatty acids or mono- or di-acylglycerols from foodstuffs, or triterpenoid resin compounds exposed to high temperatures. One suspected resin sample was shown to contain no organic residues. and it is seen that resin samples with similar physical appearances have different chemical compositions. FT-IR is proposed as a quick and cheap method of screening archaeological samples before subjecting them to the more expensive and time-consuming method of GC-MS. This will eliminate inorganic samples such as clays and ochre from CC-MS analysis, and will screen those samples which are most likely to have a high concentration of preserved organic residues. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first IUPAC Manual of Symbols and Terminology for Physicochemical Quantities and Units (the Green Book) of which this is the direct successor, was published in 1969, with the object of 'securing clarity and precision, and wider agreement in the use of symbols, by chemists in different countries, among physicists, chemists and engineers, and by editors of scientific journals'. Subsequent revisions have taken account of many developments in the field, culminating in the major extension and revision represented by the 1988 edition under the simplified title Quantities, Units and Symbols in Physical Chemistry. This 2007, third edition, is a further revision of the material which reflects the experience of the contributors with the previous editions. The book has been systematically brought up to date and new sections have been added. It strives to improve the exchange of scientific information among the readers in different disciplines and across different nations. In a rapidly expanding volume of scientific literature where each discipline has a tendency to retreat into its own jargon this book attempts to provide a readable compilation of widely used terms and symbols from many sources together with brief understandable definitions. This is the definitive guide for scientists and organizations working across a multitude of disciplines requiring internationally approved nomenclature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Bureau International des Poids et Mesures, the BIPM, was established by Article 1 of the Convention du Mètre, on 20 May 1875, and is charged with providing the basis for a single, coherent system of measurements to be used throughout the world. The decimal metric system, dating from the time of the French Revolution, was based on the metre and the kilogram. Under the terms of the 1875 Convention, new international prototypes of the metre and kilogram were made and formally adopted by the first Conférence Générale des Poids et Mesures (CGPM) in 1889. Over time this system developed, so that it now includes seven base units. In 1960 it was decided at the 11th CGPM that it should be called the Système International d’Unités, the SI (in English: the International System of Units). The SI is not static but evolves to match the world’s increasingly demanding requirements for measurements at all levels of precision and in all areas of science, technology, and human endeavour. This document is a summary of the SI Brochure, a publication of the BIPM which is a statement of the current status of the SI. The seven base units of the SI, listed in Table 1, provide the reference used to define all the measurement units of the International System. As science advances, and methods of measurement are refined, their definitions have to be revised. The more accurate the measurements, the greater the care required in the realization of the units of measurement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of special units for logarithmic ratio quantities is reviewed. The neper is used with a natural logarithm (logarithm to the base e) to express the logarithm of the amplitude ratio of two pure sinusoidal signals, particularly in the context of linear systems where it is desired to represent the gain or loss in amplitude of a single-frequency signal between the input and output. The bel, and its more commonly used submultiple, the decibel, are used with a decadic logarithm (logarithm to the base 10) to measure the ratio of two power-like quantities, such as a mean square signal or a mean square sound pressure in acoustics. Thus two distinctly different quantities are involved. In this review we define the quantities first, without reference to the units, as is standard practice in any system of quantities and units. We show that two different definitions of the quantity power level, or logarithmic power ratio, are possible. We show that this leads to two different interpretations for the meaning and numerical values of the units bel and decibel. We review the question of which of these alternative definitions is actually used, or is used by implication, by workers in the field. Finally, we discuss the relative advantages of the alternative definitions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The definitions of the base units of the international system of units have been revised many times since the idea of such an international system was first conceived at the time of the French revolution. The objective today is to define all our units in terms of 'invariants of nature', i.e. by referencing our units to the fundamental constants of physics, or the properties of atoms, rather than the characteristics of our planet or of artefacts. This situation is reviewed, particularly in regard to finding a new definition of the kilogram to replace its present definition in terms of a prototype material artefact.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The definition of coherent derived units in the International System of Units (SI) is reviewed, and the important role of the equations defining physical quantities is emphasized in obtaining coherent derived units. In the case of the dimensionless quantity plane angle, the choice between alternative definitions is considered, leading to a corresponding choice between alternative definitions of the coherent derived unit - the radian, degree or revolution. In this case the General Conference on Weights and Measures (CGPM) has chosen to adopt the definition that leads to the radian as the coherent derived unit in the SI. In the case of the quantity logarithmic decay (or gain), also sometimes called decrement, and sometimes called level, a similar choice of defining equation exists, leading to a corresponding choice for the coherent derived unit - the neper or the bel. In this case the CGPM has not yet made a choice. We argue that for the quantity logarithmic decay the most logical choice of defining equation is linked to that of the radian, and is that which leads to the neper as the corresponding coherent derived unit. This should not prevent us from using the bel and decibel as units of logarithmic decay. However, it is an important part of the SI to establish in a formal sense the equations defining physical quantities, and the corresponding coherent derived units.