21 resultados para thermal protection systems

em CentAUR: Central Archive University of Reading - UK


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Many developing countries are currently engaged in designing and implementing plant variety protection systems. Encouraging private investment in plant breeding is the key rationale for extending intellectual property rights to plant varieties. However, the design of plant variety protection systems in developing countries has been dominated by concerns regarding the inequities of a plant variety protection system, especially the imbalance in the reward structure between plant breeders and farmers. The private seed industry, a key stakeholder in plant variety protection, appears to be playing only a peripheral role in the design of the intellectual property rights regime. This paper explores the potential response of the private seed industry in India to plant variety protection legislation based on a survey of major plant breeding companies. The survey finds that the private seed industry in India is generally unenthusiastic about the legislation and plant variety protection is likely to have only a very limited impact on their research profile and expenditures on plant breeding. Measures designed to curb the 'excessive' profits of breeders, farmers' rights provisions and poor prospects for enforcement of rights are seen to be seriously diluting breeders' rights, leaving few incentives for innovation. If the fundamental objective of plant variety protection is to stimulate private investment in plant breeding, then developing countries need to seriously address the question of improving appropriability of returns from investment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The increased use of technology is necessary in order for industrial control systems to maintain and monitor industrial, infrastructural, or environmental processes. The need to secure and identify threats to the system is equally critical. Securing Critical Infrastructures and Critical Control Systems: Approaches for Threat Protection provides a full and detailed understanding of the vulnerabilities and security threats that exist within an industrial control system. This collection of research defines and analyzes the technical, procedural, and managerial responses to securing these systems.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper concerns the innovative use of a blend of systems thinking ideas in the ‘Munro Review of Child Protection’, a high-profile examination of child protection activities in England, conducted for the Department for Education. We go ‘behind the scenes’ to describe the OR methodologies and processes employed. The circumstances that led to the Review are outlined. Three specific contributions that systems thinking made to the Review are then described. First, the systems-based analysis and visualisation of how a ‘compliance culture’ had grown up. Second the creation of a large, complex systems map of current operations and the effects of past policies on them. Third, how the map gave shape to the range of issues the Review addressed and acted as an organising framework for the systemically coherent set of recommendations made. The paper closes with an outline of the main implementation steps taken so far to create a child protection system with the critically reflective properties of a learning organisation, and methodological reflections on the benefits of systems thinking to support organisational analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the advent of the internet in every day life in the 1990s, the barriers to producing, distributing and consuming multimedia data such as videos, music, ebooks, etc. have steadily been lowered for most computer users so that almost everyone with internet access can join the online communities who both produce, consume and of course also share media artefacts. Along with this trend, the violation of personal data privacy and copyright has increased with illegal file sharing being rampant across many online communities particularly for certain music genres and amongst the younger age groups. This has had a devastating effect on the traditional media distribution market; in most cases leaving the distribution companies and the content owner with huge financial losses. To prove that a copyright violation has occurred one can deploy fingerprinting mechanisms to uniquely identify the property. However this is currently based on only uni-modal approaches. In this paper we describe some of the design challenges and architectural approaches to multi-modal fingerprinting currently being examined for evaluation studies within a PhD research programme on optimisation of multi-modal fingerprinting architectures. Accordingly we outline the available modalities that are being integrated through this research programme which aims to establish the optimal architecture for multi-modal media security protection over the internet as the online distribution environment for both legal and illegal distribution of media products.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Architects and engineers depend on copyright law to protect their original works. Copyright protection is automatic once a tangible medium of expression in any form of an innovative material, conforming the Copyright Designs and Patents Act 1988, is created. In terms of architectural works, they are protected as literary works (design drawings and plans) and as artistic works (the building or model of the building). The case law on the concept of “originality” however discloses that it may be difficult for certain artistic works of architecture to achieve copyright protection. Although copyright law provides automatic protection to all original architectural plans, the limitation is that it only protects the expression of ideas but not the ideas themselves. The purpose of this research is to explore how effective the UK’s copyright law regime is for protecting the rights and interests of architects in their works. In addition, the United States system of copyright law will be analysed to determine whether it provides more effective protection for architects and engineers with regard to architectural works. The key objective in carrying out this comparison is to compare and contrast the extent to which the two systems protect the rights and interests of architects against copyright infringement. This comparative analysis concludes by considering the possibility of copyright law reform in the UK.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The method of distributing the outdoor air in classrooms has a major impact on indoor air quality and thermal comfort of pupils. In a previous study, ([11] Karimipanah T, Sandberg M, Awbi HB. A comparative study of different air distribution systems in a classroom. In: Proceedings of Roomvent 2000, vol. II, Reading, UK, 2000. p. 1013-18; [13] Karimipanah T, Sandberg M, Awbi HB, Blomqvist C. Effectiveness of confluent jets ventilation system for classrooms. In: Idoor Air 2005, Beijing, China, 2005 (to be presented).) presented results for four and two types of air distribution systems tested in a purpose built classroom with simulated occupancy as well as computational fluid dynamics (CFD) modelling. In this paper, the same experimental setup has been used to investigate the indoor environment in the classroom using confluent jet ventilation, see also ([12]Cho YJ, Awbi HB, Karimipanah T. The characteristics of wall confluent jets for ventilated enclosures. In: Proceedings of Roomvent 2004, Coimbra, Portugal, 2004.) Measurements of air speed, air temperature and tracer gas concentrations have been carried out for different thermal conditions. In addition, 56 cases of CFD simulations have been carried to provide additional information on the indoor air quality and comfort conditions throughout the classroom, such as ventilation effectiveness, air exchange effectiveness, effect of flow rate, effect of radiation, effect of supply temperature, etc., and these are compared with measured data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Maillard reaction causes changes to protein structure and occurs in foods mainly during thermal treatment. Melanoidins, the final products of the Maillard reaction, may enter the gastrointestinal tract, which is populated by different species of bacteria. In this study, melanoidins were prepared from gluten and glucose. Their effect on the growth of faecal bacteria was determined in culture with genotype and phenotype probes to identify the different species involved. Analysis of peptic and tryptic digests showed that low molecular mass products are formed from the degradation of melanoidins. Results showed a change in the growth of bacteria. This in vitro study demonstrated that melanoidins, prepared from gluten and glucose, affect the growth of the gut microflora.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Occupants’ behaviour when improving the indoor environment plays a significant role in saving energy in buildings. Therefore the key step to reducing energy consumption and carbon emissions from buildings is to understand how occupants interact with the environment they are exposed to in terms of achieving thermal comfort and well-being; though such interaction is complex. This paper presents a dynamic process of occupant behaviours involving technological, personal and psychological adaptations in response to varied thermal conditions based on the data covering four seasons gathered from the field study in Chongqing, China. It demonstrates that occupants are active players in environmental control and their adaptive responses are driven strongly by ambient thermal stimuli and vary from season to season and from time to time, even on the same day. Positive, dynamic, behavioural adaptation will help save energy used in heating and cooling buildings. However, when environmental parameters cannot fully satisfy occupants’ requirements, negative behaviours could conflict with energy saving. The survey revealed that about 23% of windows are partly open for fresh air when air-conditioners are in operation in summer. This paper addresses the issues how the building and environmental systems should be designed, operated and managed in a way that meets the requirements of energy efficiency without compromising wellbeing and productivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Air distribution systems are one of the major electrical energy consumers in air-conditioned commercial buildings which maintain comfortable indoor thermal environment and air quality by supplying specified amounts of treated air into different zones. The sizes of air distribution lines affect energy efficiency of the distribution systems. Equal friction and static regain are two well-known approaches for sizing the air distribution lines. Concerns to life cycle cost of the air distribution systems, T and IPS methods have been developed. Hitherto, all these methods are based on static design conditions. Therefore, dynamic performance of the system has not been yet addressed; whereas, the air distribution systems are mostly performed in dynamic rather than static conditions. Besides, none of the existing methods consider any aspects of thermal comfort and environmental impacts. This study attempts to investigate the existing methods for sizing of the air distribution systems and proposes a dynamic approach for size optimisation of the air distribution lines by taking into account optimisation criteria such as economic aspects, environmental impacts and technical performance. These criteria have been respectively addressed through whole life costing analysis, life cycle assessment and deviation from set-point temperature of different zones. Integration of these criteria into the TRNSYS software produces a novel dynamic optimisation approach for duct sizing. Due to the integration of different criteria into a well- known performance evaluation software, this approach could be easily adopted by designers in busy nature of design. Comparison of this integrated approach with the existing methods reveals that under the defined criteria, system performance is improved up to 15% compared to the existing methods. This approach is interpreted as a significant step forward reaching to the net zero emission building in future.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This review investigates the performance of photovoltaic and solar-assisted ground-source heat pumps in which solar heat is transferred to the ground to improve the coefficient of performance. A number of studies indicate that, for systems with adequately sized ground heat exchangers, the effect on system efficiency is small: about 1% improvement if the heat source is photovoltaic, a 1–2% decline if the source is solar thermal. With possible exceptions for systems in which the ground heat exchanger is undersized, or natural recharge from ground water is insufficient, solar thermal energy is better used for domestic hot water than to recharge ground heat. This appears particularly true outside the heating season, as although much of the heat extracted from the ground can be replaced, it seems to have little effect on the coefficient of performance. Any savings in electrical consumption that do result from an improved coefficient can easily be outweighed by an inefficient control system for the circulation pumps.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The probabilistic projections of climate change for the United Kingdom (UK Climate Impacts Programme) show a trend towards hotter and drier summers. This suggests an expected increase in cooling demand for buildings – a conflicting requirement to reducing building energy needs and related CO2 emissions. Though passive design is used to reduce thermal loads of a building, a supplementary cooling system is often necessary. For such mixed-mode strategies, indirect evaporative cooling is investigated as a low energy option in the context of a warmer and drier UK climate. Analysis of the climate projections shows an increase in wet-bulb depression; providing a good indication of the cooling potential of an evaporative cooler. Modelling a mixed-mode building at two different locations, showed such a building was capable of maintaining adequate thermal comfort in future probable climates. Comparing the control climate to the scenario climate, an increase in the median of evaporative cooling load is evident. The shift is greater for London than for Glasgow with a respective 71.6% and 3.3% increase in the median annual cooling load. The study shows evaporative cooling should continue to function as an effective low-energy cooling technique in future, warming climates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, the global market potential of solar thermal, photovoltaic (PV) and combined photovoltaic/thermal (PV/T) technologies in current time and near future was discussed. The concept of the PV/T and the theory behind the PV/T operation were briefly introduced, and standards for evaluating technical, economic and environmental performance of the PV/T systems were addressed. A comprehensive literature review into R&D works and practical application of the PV/T technology was illustrated and the review results were critically analysed in terms of PV/T type and research methodology used. The major features, current status, research focuses and existing difficulties/barriers related to the various types of PV/T were identified. The research methods, including theoretical analyses and computer simulation, experimental and combined experimental/theoretical investigation, demonstration and feasibility study, as well as economic and environmental analyses, applied into the PV/T technology were individually discussed, and the achievement and problems remaining in each research method category were described. Finally, opportunities for further work to carry on PV/T study were identified. The review research indicated that air/water-based PV/T systems are the commonly used technologies but their thermal removal effectiveness is lower. Refrigerant/heat-pipe-based PV/Ts, although still in research/laboratory stage, could achieve much higher solar conversion efficiencies over the air/water-based systems. However, these systems were found a few technical challenges in practice which require further resolutions. The review research suggested that further works could be undertaken to (1) develop new feasible, economic and energy efficient PV/T systems; (2) optimise the structural/geometrical configurations of the existing PV/T systems; (3) study long term dynamic performance of the PV/T systems; (4) demonstrate the PV/T systems in real buildings and conduct the feasibility study; and (5) carry on advanced economic and environmental analyses. This review research helps finding the questions remaining in PV/T technology, identify new research topics/directions to further improve the performance of the PV/T, remove the barriers in PV/T practical application, establish the standards/regulations related to PV/T design and installation, and promote its market penetration throughout the world.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The heat pump market in the UK has grown rapidly over the last few years. Performance analyses of vertical ground-loop heat exchanger configurations have been widely carried out using both numerical modelling and experiments. However, research findings and design recommendations on horizontal slinky-loop and vertical slinky-loop heat exchangers are far fewer compared with those for vertical ground-loop heat exchanger configurations, especially where the long-term operation of the systems is concerned. The paper presents the results obtained from a numerical simulation for the horizontal slinky-loop and vertical slinky-loop heat exchangers of a ground-source heat pump system. A three-dimensional numerical heat transfer model was developed to study the thermal performance of various heat exchanger configurations. The influence of the loop pitch (loop spacing) and the depth of a vertical slinky-loop installation were investigated and the thermal performance and excavation work required for the horizontal and vertical slinky-loop heat exchangers were compared. The influence of the installation depth for vertical slinky-loop configurations was also investigated. The results of this study show that the influence of the installation depth of the vertical slinky-loop heat exchanger on the thermal performance of the system is small. The maximum difference in the thermal performance between the vertical and horizontal slinky-loop heat exchangers with the same loop diameter and loop pitch is less than 5%.