11 resultados para the Finnish Masterpieces

em CentAUR: Central Archive University of Reading - UK


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Phenotype MicroArray (TM) (PM) technology was used to study the metabolic characteristics of 29 Salmonella strains belonging to seven serotypes of S. enterica spp. enterica. Strains of serotypes Typhimurium (six strains among definite phage types DTs 1, 40 and 104) and Agona (two strains) were tested for 949 substrates, Enteritidis (six strains of phage type PT1), Give, Hvittingfoss, Infantis and Newport strains (two of each) were tested for 190 substrates and seven other Agona strains for 95 substrates. The strains represented 18 genotypes in pulsed-field gel electrophoresis (PFGE). Among 949 substrates, 18 were identified that could be used to differentiate between the strains of those seven serotypes or within a single serotype. Unique metabolic differences between the Finnish endemic Typhimurium DT1 and Agona strains were detected, for example, in the metabolism of d-tagatose, d-galactonic acid gamma-lactone and l-proline as a carbon source. Thus, the PM technique is a useful tool for identifying potential differential markers on a metabolic basis that could be used for epidemiological surveillance.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Three land-fast ice stations (one of them was the Finnish research ice breaker Aranda) and the German research aircraft Falcon were applied to measure the turbulent and radiation fluxes over the ice edge zone in the northern Baltic Sea during the Baltic Air-Sea-Ice Study (BASIS) field experiment from 16 February to 6 March 1998. The temporal and spatial variability of the surface fluxes is discussed. Synoptic weather systems passed the experimental area in a rapid sequence and dominated the conditions (wind speed, airsurface temperature difference, cloud field) for the variability of the turbulent and radiation fluxes. At the ice stations, the largest upward sensible heat fluxes of about 100 Wm�2 were measured during the passage of a cold front when the air cooled faster (�5 K per hour) than the surface. The largest downward flux of about �200 Wm�2 occurred during warm air advection when the air temperature reached +10�C but the surface temperature remained at 0�C. Spatial variability of fluxes was observed from the small scale (scale of ice floes and open water spots) to the mesoscale (width of the ice edge zone). The degree of spatial variability depends on the synoptic situation: during melting conditions downward heat fluxes were the same over ice and open water, whereas during strong cold-air advection upward heat fluxes differed by more than 100 Wm�2. A remarkable amount of grey ice with intermediate surface temperature was observed. The ice in the Baltic Sea cannot be described by one ice type only.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of the article is to present and discuss a study in which Finnish, English and Swedish teachers and student teachers described the implications of being a teacher. It is cross-national and consists of multiple case studies. Data were collected through twenty-four focus group dialogues, and 110 teachers/student teachers participated in the study. According to the study, we have found that teachers and student teachers in all three countries promoted pupils’ development of critical thinking, which is another way of saying that they focused on ‘the attitudes and values’ aspect of citizenship education; however, this was most evident in the Finnish and the Swedish focus groups. In England there is a subject emphasis to the professional role, the three countries ranked the topics (the pupils; the subject; the organization; the society; teacher identity; parents) equally, in Finland the teacher role did not appear to be as post modern as in the two other countries.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Homeric epics are among the greatest masterpieces of literature, but when they were produced is not known with certainty. Here we apply evolutionary-linguistic phylogenetic statistical methods to differences in Homeric, Modern Greek and ancient Hittite vocabulary items to estimate a date of approximately 710–760 BCE for these great works. Our analysis compared a common set of vocabulary items among the three pairs of languages, recording for each item whether the words in the two languages were cognate – derived from a shared ancestral word – or not. We then used a likelihood-based Markov chain Monte Carlo procedure to estimate the most probable times in years separating these languages given the percentage of words they shared, combined with knowledge of the rates at which different words change. Our date for the epics is in close agreement with historians' and classicists' beliefs derived from historical and archaeological sources.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Finnish Meteorological Institute, in collaboration with the University of Helsinki, has established a new ground-based remote-sensing network in Finland. The network consists of five topographically, ecologically and climatically different sites distributed from southern to northern Finland. The main goal of the network is to monitor air pollution and boundary layer properties in near real time, with a Doppler lidar and ceilometer at each site. In addition to these operational tasks, two sites are members of the Aerosols, Clouds and Trace gases Research InfraStructure Network (ACTRIS); a Ka band cloud radar at Sodankylä will provide cloud retrievals within CloudNet, and a multi-wavelength Raman lidar, PollyXT (POrtabLe Lidar sYstem eXTended), in Kuopio provides optical and microphysical aerosol properties through EARLINET (the European Aerosol Research Lidar Network). Three C-band weather radars are located in the Helsinki metropolitan area and are deployed for operational and research applications. We performed two inter-comparison campaigns to investigate the Doppler lidar performance, compare the backscatter signal and wind profiles, and to optimize the lidar sensitivity through adjusting the telescope focus length and data-integration time to ensure sufficient signal-to-noise ratio (SNR) in low-aerosol-content environments. In terms of statistical characterization, the wind-profile comparison showed good agreement between different lidars. Initially, there was a discrepancy in the SNR and attenuated backscatter coefficient profiles which arose from an incorrectly reported telescope focus setting from one instrument, together with the need to calibrate. After diagnosing the true telescope focus length, calculating a new attenuated backscatter coefficient profile with the new telescope function and taking into account calibration, the resulting attenuated backscatter profiles all showed good agreement with each other. It was thought that harsh Finnish winters could pose problems, but, due to the built-in heating systems, low ambient temperatures had no, or only a minor, impact on the lidar operation – including scanning-head motion. However, accumulation of snow and ice on the lens has been observed, which can lead to the formation of a water/ice layer thus attenuating the signal inconsistently. Thus, care must be taken to ensure continuous snow removal.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

During the last few years Enterprise Architecture has received increasing attention among industry and academia. Enterprise Architecture (EA) can be defined as (i) a formal description of the current and future state(s) of an organisation, and (ii) a managed change between these states to meet organisation’s stakeholders’ goals and to create value to the organisation. By adopting EA, organisations may gain a number of benefits such as better decision making, increased revenues and cost reductions, and alignment of business and IT. To increase the performance of public sector operations, and to improve public services and their availability, the Finnish Parliament has ratified the Act on Information Management Governance in Public Administration in 2011. The Act mandates public sector organisations to start adopting EA by 2014, including Higher Education Institutions (HEIs). Despite the benefits of EA and the Act, EA adoption level and maturity in Finnish HEIs are low. This is partly caused by the fact that EA adoption has been found to be difficult. Thus there is a need for a solution to help organisations to adopt EA successfully. This thesis follows Design Science (DS) approach to improve traditional EA adoption method in order to increase the likelihood of successful adoption. First a model is developed to explain the change resistance during EA adoption. To find out problems associated with EA adoption, an EA-pilot conducted in 2010 among 12 Finnish HEIs was analysed using the model. It was found that most of the problems were caused by misunderstood EA concepts, attitudes, and lack of skills. The traditional EA adoption method does not pay attention to these. To overcome the limitations of the traditional EA adoption method, an improved EA Adoption Method (EAAM) is introduced. By following EAAM, organisations may increase the likelihood of successful EA adoption. EAAM helps in acquiring the mandate for EA adoption from top-management, which has been found to be crucial to success. It also helps in supporting individual and organisational learning, which has also found to be essential in successful adoption.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The semi-distributed, dynamic INCA-N model was used to simulate the behaviour of dissolved inorganic nitrogen (DIN) in two Finnish research catchments. Parameter sensitivity and model structural uncertainty were analysed using generalized sensitivity analysis. The Mustajoki catchment is a forested upstream catchment, while the Savijoki catchment represents intensively cultivated lowlands. In general, there were more influential parameters in Savijoki than Mustajoki. Model results were sensitive to N-transformation rates, vegetation dynamics, and soil and river hydrology. Values of the sensitive parameters were based on long-term measurements covering both warm and cold years. The highest measured DIN concentrations fell between minimum and maximum values estimated during the uncertainty analysis. The lowest measured concentrations fell outside these bounds, suggesting that some retention processes may be missing from the current model structure. The lowest concentrations occurred mainly during low flow periods; so effects on total loads were small.