This paper describes the design, implementation and characterisation of a contactless power transfer system for rotating applications. The power transfer system is based upon a zero-voltage-switched, full-bridge, DC-DC converter, but utilises a non-standard transformer. This transformer allows power transfer between its primary and secondary windings while also allowing free rotation between these windings. The aim of this research is to develop a solution that could replace mechanical slip-rings in certain applications where a non-contacting system would be advantageous. Based upon the design method presented in this paper, a 2 kW prototype system is constructed. Results obtained from testing the 2 kW prototype are presented and discussed. This discussion considers how the performance of the transformer varies with rotation and also the overall efficiency of the system

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In applications such as radar and wind turbines, it is often necessary to transfer power across a constantly rotating interface. As the rotation is continuous, it would be impossible to use wires to transfer the power as they would soon become twisted and stretched and the system would fail. The widespread solution to this problem is to use a slip-ring.