5 resultados para sample processing

em CentAUR: Central Archive University of Reading - UK


Relevância:

60.00% 60.00%

Publicador:

Resumo:

There are several advantages of using metabolic labeling in quantitative proteomics. The early pooling of samples compared to post-labeling methods eliminates errors from different sample processing, protein extraction and enzymatic digestion. Metabolic labeling is also highly efficient and relatively inexpensive compared to commercial labeling reagents. However, methods for multiplexed quantitation in the MS-domain (or ‘non-isobaric’ methods), suffer from signal dilution at higher degrees of multiplexing, as the MS/MS signal for peptide identification is lower given the same amount of peptide loaded onto the column or injected into the mass spectrometer. This may partly be overcome by mixing the samples at non-uniform ratios, for instance by increasing the fraction of unlabeled proteins. We have developed an algorithm for arbitrary degrees of nonisobaric multiplexing for relative protein abundance measurements. We have used metabolic labeling with different levels of 15N, but the algorithm is in principle applicable to any isotope or combination of isotopes. Ion trap mass spectrometers are fast and suitable for LC-MS/MS and peptide identification. However, they cannot resolve overlapping isotopic envelopes from different peptides, which makes them less suitable for MS-based quantitation. Fourier-transform ion cyclotron resonance (FTICR) mass spectrometry is less suitable for LC-MS/MS, but provides the resolving power required to resolve overlapping isotopic envelopes. We therefore combined ion trap LC-MS/MS for peptide identification with FTICR LC-MS for quantitation using chromatographic alignment. We applied the method in a heat shock study in a plant model system (A. thaliana) and compared the results with gene expression data from similar experiments in literature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The period, known to UK farmers and processors as the "spring flush", when the cows' diet changes from dry feed to spring pasture, has long been established as a time of change in milk properties and processing characteristics. Although it is believed to be a time when problems in processing are most likely to occur (e.g. milk that does not form clots or forms weak gels during cheesemaking), there is little evidence in the literature of detailed changes in milk composition and their impact on product manufacture. In this study, a range of physicochemical properties were analysed in milk collected from five commercial dairy herds before, during and after the spring flush period of 2006. In particular, total and ionic calcium contents of milk were studied in relation to other parameters including rennet clotting, acid gel properties, heat coagulation, alcohol stability, micelle size and zeta potential. Total divalent cations were significantly reduced from 35.4 to 33.4 mmol.L-1 during the study, while ionic calcium was reduced from 1.48 to 1.40 mmol.L-1 over the same period. Many parameters varied significantly between the sample dates. However, there was no evidence to suggest that any of the milk samples would have been unsuitable for processing - e.g. there were no samples that did not form clots with chymosin within a reasonable time or formed especially weak rennet or acid gels. A number of statistically significant correlations were found within the data, including ionic calcium concentration and pH; rennet clotting time (RCT) and micelle diameter; and RCT and ethanol stability. Overall, while there were clear variations in milk composition and properties over this period, there was no evidence to support the view that serious processing problems are likely during the change from dry feed to spring pasture.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article analyses the results of an empirical study on the 200 most popular UK-based websites in various sectors of e-commerce services. The study provides empirical evidence on unlawful processing of personal data. It comprises a survey on the methods used to seek and obtain consent to process personal data for direct marketing and advertisement, and a test on the frequency of unsolicited commercial emails (UCE) received by customers as a consequence of their registration and submission of personal information to a website. Part One of the article presents a conceptual and normative account of data protection, with a discussion of the ethical values on which EU data protection law is grounded and an outline of the elements that must be in place to seek and obtain valid consent to process personal data. Part Two discusses the outcomes of the empirical study, which unveils a significant departure between EU legal theory and practice in data protection. Although a wide majority of the websites in the sample (69%) has in place a system to ask separate consent for engaging in marketing activities, it is only 16.2% of them that obtain a consent which is valid under the standards set by EU law. The test with UCE shows that only one out of three websites (30.5%) respects the will of the data subject not to receive commercial communications. It also shows that, when submitting personal data in online transactions, there is a high probability (50%) of incurring in a website that will ignore the refusal of consent and will send UCE. The article concludes that there is severe lack of compliance of UK online service providers with essential requirements of data protection law. In this respect, it suggests that there is inappropriate standard of implementation, information and supervision by the UK authorities, especially in light of the clarifications provided at EU level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Traditional chemometrics techniques are augmented with algorithms tailored specifically for the de-noising and analysis of femtosecond duration pulse datasets. The new algorithms provide additional insights on sample responses to broadband excitation and multi-moded propagation phenomena.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Expression microarrays are increasingly used to obtain large scale transcriptomic information on a wide range of biological samples. Nevertheless, there is still much debate on the best ways to process data, to design experiments and analyse the output. Furthermore, many of the more sophisticated mathematical approaches to data analysis in the literature remain inaccessible to much of the biological research community. In this study we examine ways of extracting and analysing a large data set obtained using the Agilent long oligonucleotide transcriptomics platform, applied to a set of human macrophage and dendritic cell samples. Results: We describe and validate a series of data extraction, transformation and normalisation steps which are implemented via a new R function. Analysis of replicate normalised reference data demonstrate that intrarray variability is small (only around 2 of the mean log signal), while interarray variability from replicate array measurements has a standard deviation (SD) of around 0.5 log(2) units (6 of mean). The common practise of working with ratios of Cy5/Cy3 signal offers little further improvement in terms of reducing error. Comparison to expression data obtained using Arabidopsis samples demonstrates that the large number of genes in each sample showing a low level of transcription reflect the real complexity of the cellular transcriptome. Multidimensional scaling is used to show that the processed data identifies an underlying structure which reflect some of the key biological variables which define the data set. This structure is robust, allowing reliable comparison of samples collected over a number of years and collected by a variety of operators. Conclusions: This study outlines a robust and easily implemented pipeline for extracting, transforming normalising and visualising transcriptomic array data from Agilent expression platform. The analysis is used to obtain quantitative estimates of the SD arising from experimental (non biological) intra- and interarray variability, and for a lower threshold for determining whether an individual gene is expressed. The study provides a reliable basis for further more extensive studies of the systems biology of eukaryotic cells.