28 resultados para rooms

em CentAUR: Central Archive University of Reading - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The internal partitioning, which is frequently introduced in open-space planning due to its flexibility, was tested to study its effects on the room air quality as well as ventilation performance. For the study, physical tests using a small model room and numerical modeling using CFD computation were utilized to evaluate different test conditions employing mixing ventilation from the ceiling. The partition parameters, such as its location, height, and the gap underneath, as well as contaminant source location were tested under isothermal conditions. This paper summarizes the results from the study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three experiments measured constancy in speech perception, using natural-speech messages or noise-band vocoder versions of them. The eight vocoder-bands had equally log-spaced center-frequencies and the shapes of corresponding “auditory” filters. Consequently, the bands had the temporal envelopes that arise in these auditory filters when the speech is played. The “sir” or “stir” test-words were distinguished by degrees of amplitude modulation, and played in the context; “next you’ll get _ to click on.” Listeners identified test-words appropriately, even in the vocoder conditions where the speech had a “noise-like” quality. Constancy was assessed by comparing the identification of test-words with low or high levels of room reflections across conditions where the context had either a low or a high level of reflections. Constancy was obtained with both the natural and the vocoded speech, indicating that the effect arises through temporal-envelope processing. Two further experiments assessed perceptual weighting of the different bands, both in the test word and in the context. The resulting weighting functions both increase monotonically with frequency, following the spectral characteristics of the test-word’s [s]. It is suggested that these two weighting functions are similar because they both come about through the perceptual grouping of the test-word’s bands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When speech is in competition with interfering sources in rooms, monaural indicators of intelligibility fail to take account of the listener’s abilities to separate target speech from interfering sounds using the binaural system. In order to incorporate these segregation abilities and their susceptibility to reverberation, Lavandier and Culling [J. Acoust. Soc. Am. 127, 387–399 (2010)] proposed a model which combines effects of better-ear listening and binaural unmasking. A computationally efficient version of this model is evaluated here under more realistic conditions that include head shadow, multiple stationary noise sources, and real-room acoustics. Three experiments are presented in which speech reception thresholds were measured in the presence of one to three interferers using real-room listening over headphones, simulated by convolving anechoic stimuli with binaural room impulse-responses measured with dummy-head transducers in five rooms. Without fitting any parameter of the model, there was close correspondence between measured and predicted differences in threshold across all tested conditions. The model’s components of better-ear listening and binaural unmasking were validated both in isolation and in combination. The computational efficiency of this prediction method allows the generation of complex “intelligibility maps” from room designs. © 2012 Acoustical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three-dimensional computational simulations are performed to examine indoor environment and micro-environment around human bodies in an office in terms of thermal environment and air quality. In this study, personal displacement ventilation (PDV), including two cases with all seats taken and two middle seats taken, is compared with overall displacement ventilation (ODV) of all seats taken under the condition that supply temperature is 24℃ and air change rate is 60 l/s per workstation. When using PDV, temperature stratification, the characteristic of displacement ventilation, is obviously observed at the position of occupant’s head and clearer in the case with all seats taken. Verticalertical ertical temperature temperature temperature temperature temperature differences below height of the head areare under under under 2℃ in two cases in two cases in two cases in two cases in two cases in two cases in two cases in two cases with all seats taken,and the temperature with PDV is higher than that with ODV. Verticalertical ertical temperature temperature temperature temperature temperature temperature difference is under 3 under 3under 3 under 3℃ in the case in the case in the case in the case in the case in the case in the case with two middle seats taken. CO2 concentration is lower th is lower th is lower this lower this lower than 2 g/man 2 g/m an 2 g/man 2 g/man 2 g/man 2 g/m 3 in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. The results indicate that PDV can be used in the room with big change of occupants’ number to satisfy the need of thermal comfort and air quality. When not all seats are taken, designers should increase supply air requirement or reduce its temperature for thermal comfort. INDEX TERMS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work investigated the personal exposure to indoor particulate matters using the intake fraction metric and provided a possible way to trace the particle inhaled from an indoor particle source. A turbulence model validated by the particle measurements in a room with underfloor air distribution (UFAD) system was used to predict the indoor particle concentrations. Inhalation intake fraction of indoor particles was defined and evaluated in two rooms equipped with the UFAD, i.e., the experimental room and a small office. According to the exposure characteristics and a typical respiratory rate, the intake fraction was determined in two rooms with a continuous and episodic (human cough) source of particles, respectively. The findings showed that the well-mixing assumption of indoor air failed to give an accurate estimation of inhalation exposure and the average concentration at return outlet or within the overall room could not relate well the intake fraction to the amount of particle emitted from an indoor source.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article analyzes two series of photographs and essays on writers’ rooms published in England and Canada in 2007 and 2008. The Guardian’s Writers Rooms series, with photographs by Eamon McCabe, ran in 2007. In the summer of 2008, The Vancouver International Writers and Readers Festival began to post its own version of The Guardian column on its website by displaying, each week leading up to the Festival in September, a different writer’s “writing space” and an accompanying paragraph. I argue that these images of writers’ rooms, which suggest a cultural fascination with authors’ private compositional practices and materials, reveal a great deal about theoretical constructions of authorship implicit in contemporary literary culture. Far from possessing the museum quality of dead authors’ spaces, rooms that are still being used, incorporating new forms of writing technology, and having drafts of manuscripts scattered around them, can offer insight into such well-worn and ineffable areas of speculation as inspiration, singular authorial genius, and literary productivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In England, drama is embedded into the National Curriculum as a part of the programmes of study for the subject of English. This means that all children aged between 5 - 16 in state funded schools have an entitlement to be taught some aspects of the subject. While the manifestation of drama in primary schools is diverse, in a great many schools for students aged between 11 – 19, drama and theatre art is taught as a discrete subject in the same way that the visual arts and music are. Students may opt for public examination courses in the subject at ages 16 and 18. In order to satisfy the specifications laid down for such examinations many schools recognise the need for specialist teachers and indeed specialist teaching rooms and equipment. This chapter outlines how drama is taught in secondary schools in England (there being subtle variations in the education systems in the other countries that make up the United Kingdom) and the theories that underpin drama’s place in the curriculum as a subject in its own right and as a vehicle for delivering other aspects of the prescribed curriculum are discussed. The paper goes on to review the way in which drama is taught articulates with the requirements and current initiatives laid down by the government. Given this context, the chapter moves on to explore what specialist subject and pedagogical knowledge secondary school drama teachers need. Furthermore, consideration is made of the tensions that may be seen to exist between the way drama teachers perceive their own identity as subject specialists and the restrictions and demands placed upon them by the education system within which they work. An insight into the backgrounds of those who become drama teachers in England is provided and the reasons for choosing such a career and the expectations and concerns that underpin their training are identified and analysed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Question: What are the life-history costs for a predatory insect of surviving parasitoid attack, and can parasitoid attack alter predator-prey interactions? Hypotheses: Survivorship is influenced by host age. Hosts that suffer parasitoid attack grow more slowly and consume fewer prey. Those that survive attack are smaller as adults and show reduced survivorship. Organisms: The aphidophagous hoverfly Episyrphus balteatus, its endoparasitoid wasp Diplazon laetatorius and its prey, the pea aphid, Acyrthosiphon pisum. Site of experiments: All experiments were conducted in controlled temperature rooms and chambers in the laboratory. Methods: Episyrphus balteatus larvae of each instar were exposed to attack by Diplazon laetatorius, then dissected to measure the encapsulation response (a measure of immunity). Second instar larvae were either attacked or not attacked by D. laetatorius. Their development rates and numbers of prey consumed were noted. The size and survivorship of surviving (immune) and control hoverflies were compared following eclosion. Conclusions: Successful immune response increased with larval age (first instar 0%, second instar 40%, third instar 100% survival). Second instar larvae that successfully resisted parasitoid attack were larger as pupae (but not as adults) and showed reduced adult survivorship. Female adult survivors were more likely than male survivors to have died within 16 days of eclosion, but there was no difference between unattacked male and female control hoverflies. Attacked larvae, irrespective of immune status, consumed fewer aphids than unattacked individuals. Episyrphus balteatus suffers significant costs of resisting parasitoid attack, and parasitoid attack can reduce the top-down effects of an insect predator, irrespective of whether the host mounts an immune response or not.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recently, studies have shown that the classroom environment is very important for students' health and performance. Thus, the evaluation of indoor air quality (IAQ) in a classroom is necessary to ensure students' well-being. In this paper the emphasis is on airborne concentration of particulate matter (PM) in adult education rooms. The mass concentration of PM10 particulates was measured in two classrooms under different ventilation methods in the University of Reading, UK, during the winter period of 2008. In another study the measurement of the concentration of particles was accompanied with measurements of CO2 concentration in these classrooms but this study is the subject of another publication. The ambient PM10, temperature, relative humidity, wind speed and direction, and rainfall events were monitored as well. In general, this study showed that outdoor particle concentrations and outdoor meteorological parameters were identified as significant factors influencing indoor particle concentration levels. Ventilation methods showed significant effects on air change rate and on indoor/outdoor (I/O) concentration ratios. Higher levels of indoor particulates were seen during occupancy periods. I/O ratios were significantly higher when classrooms were occupied than when they were unoccupied, indicating the effect of both people presence and outdoor particle concentration levels. The concentrations of PM10 indoors and outdoors did not meet the requirements of WHO standards for PM10 annual average.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experimental wind tunnel and smoke visualisation testing and CFD modelling were conducted to investigate the effect of air flow control mechanism and heat source inside rooms on wind catchers/towers performance. For this purpose, a full-scale wind catcher was connected to a test room and positioned centrally in an open boundary wind tunnel. Pressure coefficients (C-p's) around the wind catcher and air flow into the test room were established. The performance of the wind catcher depends greatly on the wind speed and direction. The incorporation of dampers and egg crate grille at ceiling level reduces and regulates the air flow rate with an average pressure loss coefficient of 0.01. The operation of the wind catcher in the presence of heat sources will potentially lower the internal temperatures in line with the external temperatures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Listeners were asked to identify modified recordings of the words "sir" and "stir," which were spoken by an adult male British-English speaker. Steps along a continuum between the words were obtained by a pointwise interpolation of their temporal-envelopes. These test words were embedded in a longer "context" utterance, and played with different amounts of reverberation. Increasing only the test-word's reverberation shifts the listener's category boundary so that more "sir"-identifications are made. This effect reduces when the context's reverberation is also increased, indicating perceptual compensation that is informed by the context. Experiment I finds that compensation is more prominent in rapid speech, that it varies between rooms, that it is more prominent when the test-word's reverberation is high, and that it increases with the context's reverberation. Further experiments show that compensation persists when the room is switched between the context and the test word, when presentation is monaural, and when the context is reversed. However, compensation reduces when the context's reverberation pattern is reversed, as well as when noise-versions of the context are used. "Tails" that reverberation introduces at the ends of sounds and at spectral transitions may inform the compensation mechanism about the amount of reflected sound in the signal. (c) 2005 Acoustical Society of America.