27 resultados para programmable-gain amplifier

em CentAUR: Central Archive University of Reading - UK


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, single-carrier multiple-input multiple-output (MIMO) transmit beamforming (TB) systems in the presence of high-power amplifier (HPA) nonlinearity are investigated. Specifically, due to the suboptimality of the conventional maximal ratio transmission/maximal ratio combining (MRT/MRC) under HPA nonlinearity, we propose the optimal TB scheme with the optimal beamforming weight vector and combining vector, for MIMO systems with nonlinear HPAs. Moreover, an alternative suboptimal but much simpler TB scheme, namely, quantized equal gain transmission (QEGT), is proposed. The latter profits from the property that the elements of the beamforming weight vector have the same constant modulus. The performance of the proposed optimal TB scheme and QEGT/MRC technique in the presence of the HPA nonlinearity is evaluated in terms of the average symbol error probability and mutual information with the Gaussian input, considering the transmission over uncorrelated quasi-static frequency-flat Rayleigh fading channels. Numerical results are provided and show the effects on the performance of several system parameters, namely, the HPA parameters, numbers of antennas, quadrature amplitude modulation modulation order, number of pilot symbols, and cardinality of the beamforming weight vector codebook for QEGT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The nonlinearity of high-power amplifiers (HPAs) has a crucial effect on the performance of multiple-input-multiple-output (MIMO) systems. In this paper, we investigate the performance of MIMO orthogonal space-time block coding (OSTBC) systems in the presence of nonlinear HPAs. Specifically, we propose a constellation-based compensation method for HPA nonlinearity in the case with knowledge of the HPA parameters at the transmitter and receiver, where the constellation and decision regions of the distorted transmitted signal are derived in advance. Furthermore, in the scenario without knowledge of the HPA parameters, a sequential Monte Carlo (SMC)-based compensation method for the HPA nonlinearity is proposed, which first estimates the channel-gain matrix by means of the SMC method and then uses the SMC-based algorithm to detect the desired signal. The performance of the MIMO-OSTBC system under study is evaluated in terms of average symbol error probability (SEP), total degradation (TD) and system capacity, in uncorrelated Nakagami-m fading channels. Numerical and simulation results are provided and show the effects on performance of several system parameters, such as the parameters of the HPA model, output back-off (OBO) of nonlinear HPA, numbers of transmit and receive antennas, modulation order of quadrature amplitude modulation (QAM), and number of SMC samples. In particular, it is shown that the constellation-based compensation method can efficiently mitigate the effect of HPA nonlinearity with low complexity and that the SMC-based detection scheme is efficient to compensate for HPA nonlinearity in the case without knowledge of the HPA parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To examine the basis of emotional changes to the voice, physiological and electroglottal measures were combined with acoustic speech analysis of 30 men performing a computer task in which they lost or gained points under two levels of difficulty. Predictions of the main effects of difficulty and reward on the voice were not borne out by the data. Instead, vocal changes depended largely on interactions between gain versus loss and difficulty. The rate at which the vocal folds open and close (fundamental frequency; f0) was higher for loss than for gain when difficulty was high, but not when difficulty was low. Electroglottal measures revealed that f0 changes corresponded to shorter glottal open times for the loss conditions. Longer closed and shorter open phases were consistent with raised laryngeal tension in difficult loss conditions. Similarly, skin conductance indicated higher sympathetic arousal in loss than gain conditions, particularly when difficulty was high. The results provide evidence of the physiological basis of affective vocal responses, confirming the utility of measuring physiology and voice in the study of emotion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An improved amplifier for atmospheric fine wire resistance thermometry is described. The amplifier uses a low excitation current (50 mu A). This is shown to ensure negligible self-heating of the low mass fine wire resistance sensor, compared with measured nocturnal surface air temperature fluctuations. The system provides sufficient amplification for a +/- 50 degrees C span using a +/- 5 V dynamic range analog-to-digital converter, with a noise level of less than 0.01 degrees C. A Kelvin four-wire connection cancels the effect of long lead resistances: a 50 m length of screened cable connecting the Reading design of fine wire thermometer to the amplifier produced no measurable temperature change at 12 bit resolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A highly stable microvolt amplifier for use with atmospheric broadband thermopile radiometers is described. The amplifier has a nominal gain of 500, for bipolar input signals in the range +/- 10 mV from a floating source. The noise level at the input is less than 5 mu V (at 100 k Omega input impedance), permitting instantaneous diffuse solar radiation measurements to 0.5 W m(-2) resolution with 12 bit analog to digital conversion. The temperature stability of gain is better than 5 ppm/degrees C (-4 to 20 degrees C). Averaged over a decade of use, the long term drift of the amplifier gain is less than similar to 0.02%/yr. As well as radiometers measuring solar and terrestrial radiations, the amplifier has also been successfully used with low level signals from thermocouples and ground heat flux plates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Advancing maturity of forage maize is associated with increases in the proportion of dry matter (DM) and starch, and decreases in the proportions of structural carbohydrates in the ensiled crop. This experiment investigated the effects of three maize silages of 291 (low), 339 (medium) and 393 (high) g DM per kg fresh weight on the performance of 48 Simmental. Holstein-Friesian cattle. Equal numbers of steers (mean start weight = 503 (s.d. 31.3) kg) and heifers (mean start weight = 378 (s.d. 11.2) kg) were offered individually isonitrogenous diets composed of the three silages plus a protein supplement with minerals once daily until slaughter at the target live weight of 575 and 475 kg for steers and heifers, respectively. Intake was reduced on the low diet (P < 0.01) compared with the other two treatments. Dietary starch intake increased by a total of 1 kg/day between low and medium diets but by only 0.2 kg/day between medium and high diets. Unlike starch intake, total neutral-detergent fibre intake showed no significant difference (P > 0.05) between diets. There were no differences in live-weight gain between treatments but differences (P < 0.05) in food conversion efficiency indicated relative gains of 115, 100 and 102 g gain per kg DM intake for diets low, medium and high, respectively. There were no differences between diets in carcass weights, fat score and overall conformation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The suitability of models specifically re-parameterized for analyzing energy balance data relating metabolizable energy intake to growth rate has recently been investigated in male broilers. In this study, the more adequate of those models was applied to growing turkeys to provide estimates of their energy needs for maintenance and growth. Three functional forms were used. They were: two equations representing diminishing returns behaviour (monomolecular and rectangular hyperbola); and one equation describing smooth sigmoidal behaviour with a fixed point of inflexion (Gompertz). The models estimated the metabolizable energy requirement for maintenance in turkeys to be 359-415 kJ/kg of live-weight/day. The predicted values of average net energy requirement for producing 1 g of gain in live-weight, between 1 and 4 times maintenance, varied from 8.7 to 10.9 kJ. These results and those previously reported for broilers are a basis for accepting the general validity of these models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While planning the GAIN International Study of gavestinel in acute stroke, a sequential triangular test was proposed but not implemented. Before the trial commenced it was agreed to evaluate the sequential design retrospectively to evaluate the differences in the resulting analyses, trial durations and sample sizes in order to assess the potential of sequential procedures for future stroke trials. This paper presents four sequential reconstructions of the GAIN study made under various scenarios. For the data as observed, the sequential design would have reduced the trial sample size by 234 patients and shortened its duration by 3 or 4 months. Had the study not achieved a recruitment rate that far exceeded expectation, the advantages of the sequential design would have been much greater. Sequential designs appear to be an attractive option for trials in stroke. Copyright 2004 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soluble factors such as ADP and thromboxane (TX) A(2) that are secreted or released by platelets at sites of tissue injury, mediate autocrine and paracrine regulation of platelet function, resulting in rapid localised thrombus formation. The suppression of platelet function, particularly through targeting such secondary regulatory mechanisms, that serve to 'fine-tune' the platelet response, has proven effective in the prevention of inappropriate platelet activation that results in thrombosis. The most commonly used anti-platelet approaches (ADP receptor antagonism or inhibition of TXA(2) synthesis), however, lack efficacy in many patients, suggesting the existence of additional uncharacterised mechanisms for the regulation of platelet function. Recent data, which form a focus of this review, have identified peripheral tachykinin peptide family members, such as substance P and the newly identified endokinins, as physiologically important positive feedback regulators of platelet function. The actions of tachykinins that are released from platelets during activation are mediated by the neurokinin-1 receptor. Initial analysis of the role of this receptor in platelet thrombus formation, and thrombosis in the mouse, indicate this to be a promising new target for the development of anti-thrombotic drugs. (C) 2008 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Motivation: We compare phylogenetic approaches for inferring functional gene links. The approaches detect independent instances of the correlated gain and loss of pairs of genes from species' genomes. We investigate the effect on results of basing evidence of correlations on two phylogenetic approaches, Dollo parsminony and maximum likelihood (ML). We further examine the effect of constraining the ML model by fixing the rate of gene gain at a low value, rather than estimating it from the data. Results: We detect correlated evolution among a test set of pairs of yeast (Saccharomyces cerevisiae) genes, with a case study of 21 eukaryotic genomes and test data derived from known yeast protein complexes. If the rate at which genes are gained is constrained to be low, ML achieves by far the best results at detecting known functional links. The model then has fewer parameters but it is more realistic by preventing genes from being gained more than once. Availability: BayesTraits by M. Pagel and A. Meade, and a script to configure and repeatedly launch it by D. Barker and M. Pagel, are available at http://www.evolution.reading.ac.uk .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The two major applications of microwave remote sensors are radiometer and radar. Because of its importance and the nature of the application, much research has been made on the various aspects of the radar. This paper will focus on the various aspects of the radiometer from a design point of view and the Low Noise Amplifier will be designed and implemented. The paper is based on a study in radio Frequency Communications engineering and understanding of electronic and RF circuits. Some research study about the radiometer and practical implementation of Low Noise Amplifier for Radiometer will be the main focus of this paper. Basically the paper is divided into two parts. In the first part some background study about the radiometer will be carried out and commonly used types of radiometer will be discussed. In the second part LNA for the radiometer will be designed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increasing rates of obesity have stimulated research into possible contributing factors, including specific dietary components such as trans fatty acids (TFAs). This review considers the evidence for an association between TFA intake and weight gain. It concludes that there is limited but consistent evidence from epidemiological studies, and from a primate model, that increased TFA consumption may result in a small additional weight gain. Data from a long-term study in a primate model suggest that TFA may have a greater adipogenic effect than cis monounsaturated fatty acids; however, there are currently inadequate mechanistic data to provide a comprehensive and plausible explanation for any such metabolic differences between the types of fatty acids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A person with a moderate or severe motor disability will often use specialised or adapted tools to assist their interaction with a general environment. Such tools can assist with the movement of a person's arms so as to facilitate manipulation, can provide postural supports, or interface to computers, wheelchairs or similar assistive technologies. Designing such devices with programmable stiffness and damping may offer a better means for the person to have effective control of their surroundings. This paper addresses the possibility of designing some assistive technologies using impedance elements that can adapt to the user and the circumstances. Two impedance elements are proposed. The first, based on magnetic particle brakes, allows control of the damping coefficient in a passive element. The second, based on detuning the P-D controller in a servo-motor mechanism, allows control of both stiffness and damping. Such a mechanical impedance can be modulated to the conditions imposed by the task in hand. The limits of linear theory are explored and possible uses of programmable impedance elements are proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper outlines some rehabilitation applications of manipulators and identifies that new approaches demand that the robot make an intimate contact with the user. Design of new generations of manipulators with programmable compliance along with higher level controllers that can set the compliance appropriately for the task, are both feasible propositions. We must thus gain a greater insight into the way in which a person interacts with a machine, particularly given that the interaction may be non-passive. We are primarily interested in the change in wrist and arm dynamics as the person co-contracts his/her muscles. It is observed that this leads to a change in stiffness that can push an actuated interface into a limit cycle. We use both experimental results gathered from a PHANToM haptic interface and a mathematical model to observe this effect. Results are relevant to the fields of rehabilitation and therapy robots, haptic interfaces, and telerobotics