15 resultados para particulate adjuvant

em CentAUR: Central Archive University of Reading - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The extent to which airborne particles penetrate into the human respiratory system is determined mainly by their size, with possible health effects. The research over the scientific evidence of the role of airborne particles in adverse health effects has been intensified in recent years. In the present study, seasonal variations of PM10 and its relation with anthropogenic activities have been studied by using the data from UK National Air Quality Archive over Reading, UK. The diurnal variation of PM10 shows a morning peak during 7:00-10:00 LT and an evening peak during 19:00-22:00 LT. 3 The variation between 12:00 and 17:00 LT remains more or less steady for PM10 with the minimum value of similar to 16 mu g m(-3). PM10 and black smoke (BS) concentrations during weekdays were found to be high compared to weekends. A reduction in the concentration of PM10 has been found during the Christmas holidays compared to normal days during December. Seasonal variations of PM10 showed high values during spring compared to other seasons. A linear relationship has been found between PM10 and NO, during March, July, November and December suggesting that most of the PM10 is due to local traffic exhaust emissions. PM10 and SO2 concentrations showed positive correlation with the correlation coefficient of R-2 = 0.65 over the study area. Seasonal variations of SO2 and NOx showed high concentrations during winter and low concentrations during spring. Fraction of BS in PM10 has been found to be 50% during 2004 over the study area. (C) 2005 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accumulation of surplus phosphorus (P) in the soil and the resulting increased transport of P in land runoff contribute to freshwater eutrophication. The effects of increasing soil P (19–194 mg Olsen-P (OP) kg−1) on the concentrations of particulate P (PP), and sorption properties (Qmax, k and EPCo) of suspended solids (SS) in overland flow from 15 unreplicated field plots established on a dispersive arable soil were measured over three monitoring periods under natural rainfall. Concentrations of PP in plot runoff increased linearly at a rate of 2.6 μg litre−1 per mg OP kg−1 of soil, but this rate was approximately 50% of the rate of increase in dissolved P (< 0.45 μm). Concentrations of SS in runoff were similar across all plots and contained a greater P sorption capacity (mean + 57%) than the soil because of enrichment with fine silt and clay (0.45–20 μm). As soil P increased, the P enrichment ratio of the SS declined exponentially, and the values of P saturation (Psat; 15–42%) and equilibrium P concentration (EPCo; 0.7–5.5 mg litre−1) in the SS fell within narrower ranges compared with the soils (6–74% and 0.1–10 mg litre−1, respectively). When OP was < 100 mg kg−1, Psat and EPCo values in the SS were smaller than those in the soil and vice-versa, suggesting that eroding particles from soils with both average and high P fertility would release P on entering the local (Rosemaund) stream. Increasing soil OP from average to high P fertility increased the P content of the SS by approximately 10%, but had no significant (P > 0.05) effect on the Psat, or EPCo, of the SS. Management options to reduce soil P status as a means of reducing P losses in land runoff and minimizing eutrophication risk may therefore have more limited effect than is currently assumed in catchment management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, studies have shown that the classroom environment is very important for students' health and performance. Thus, the evaluation of indoor air quality (IAQ) in a classroom is necessary to ensure students' well-being. In this paper the emphasis is on airborne concentration of particulate matter (PM) in adult education rooms. The mass concentration of PM10 particulates was measured in two classrooms under different ventilation methods in the University of Reading, UK, during the winter period of 2008. In another study the measurement of the concentration of particles was accompanied with measurements of CO2 concentration in these classrooms but this study is the subject of another publication. The ambient PM10, temperature, relative humidity, wind speed and direction, and rainfall events were monitored as well. In general, this study showed that outdoor particle concentrations and outdoor meteorological parameters were identified as significant factors influencing indoor particle concentration levels. Ventilation methods showed significant effects on air change rate and on indoor/outdoor (I/O) concentration ratios. Higher levels of indoor particulates were seen during occupancy periods. I/O ratios were significantly higher when classrooms were occupied than when they were unoccupied, indicating the effect of both people presence and outdoor particle concentration levels. The concentrations of PM10 indoors and outdoors did not meet the requirements of WHO standards for PM10 annual average.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epidemiological studies have shown links between human exposure to indoor airborne particles and adverse health affects. Several recent studies have also reported that the classroom environment has an impact on students’ health and performance. In this study particle concentration in a university classroom is assessed experimentally for different occupancy periods. The mass concentrations of different particle size ranges (0.3 – 20 µm), and the three particulate matter fractions (PM10, PM2.5, and PM1) were measured simultaneously in a classroom with different occupancy periods including occupied and unoccupied periods in the University of Reading, UK, during the winter period of 2010. The results showed that students’ presence is a significant factor affecting particles concentration for the fractions above PM1 in the measured range of 0.3 to 20 µm. The resuspension of the three PM fractions was also determined in the study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free radicals in cigarette smoke have been studied using spin trapping EPR techniques. 2R4F reference cigarettes were smoked using 35 ml puff volumes of 2 seconds duration, once every 60 seconds. The particulate phase of the smoke was separated from the gas phase by passing the smoke through a Cambridge filter pad. For both phases, free radicals were measured and identified. A range of spin-traps was employed: PBN, DMPO, DEPMPO, and DPPH-PBN. In the gas-phase, short-lived carbon- and oxygen- centered radicals were identified; the ratios between them changed during the smoking runs. For the first puffs, C-centered radicals predominated while for the later puffs, O-centered radicals were mainly observed. The particulate phase and the ‘tar’ were studied as well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hemagglutinins (HAs) of human H1 and H3 influenza viruses and avian H5 influenza virus were produced as recombinant fusion proteins with the human immunoglobulin Fc domain. Recombinant HA-human immunoglobulin Fc domain (HA-HuFc) proteins were secreted from baculovirus-infected insect cells as glycosylated oligomer HAs of the anticipated molecular mass, agglutinated red blood cells, were purified on protein A, and were used to immunize mice in the absence of adjuvant. Immunogenicity was demonstrated for all subtypes, with the serum samples demonstrating subtype-specific hemagglutination inhibition, epitope specificity similar to that seen with virus infection, and neutralization. HuFc-tagged HAs are potential candidates for gene-to-vaccine approaches to influenza vaccination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite widespread support at several public meetings, input from patient groups including representation on the Trial Management Group, the trial failed to recruit due to the inability to convince patients to accept randomisation. It would therefore seem that randomising the patients to receive chemotherapy vs observation is not a viable design in the current era for this patient population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present work is to study the occupants' exposure to fine particulate concentrations in ten nightclubs (NCs) in Athens, Greece. Measurements of PM1 and PM 2.5 were made in the outdoor and indoor environment of each NC. The average indoorPM1 andPM 2.5 concentrations were found to be 181.77 μgm−3 and 454.08 μg m−3 respectively, while the corresponding outdoor values were 11.04 μg m−3 and 32.19 μg m−3. Ventilation and resuspension rates were estimated through consecutive numerical experiments with an indoor air quality model and were found to be remarkably lower than the minimum values recommended by national standards. The relative effects of the ventilation and smoking on the occupants' exposures were examined using multiple regression techniques. Itwas found that given the low ventilation rates, the effect of smoking as well as the occupancy is of the highest importance. Numerical evaluations showed that if the ventilation rates were at the minimum values set by national standards, then the indoor exposures would be reduced at the 70% of the present exposure values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The migration of liquids in porous media, such as sand, has been commonly considered at high saturation levels with liquid pathways at pore dimensions. In this letter we reveal a low saturation regime observed in our experiments with droplets of extremely low volatility liquids deposited on sand. In this regime the liquid is mostly found within the grain surface roughness and in the capillary bridges formed at the contacts between the grains. The bridges act as variable-volume reservoirs and the flow is driven by the capillary pressure arising at the wetting front according to the roughness length scales. We propose that this migration (spreading) is the result of interplay between the bridge volume adjustment to this pressure distribution and viscous losses of a creeping flow within the roughness. The net macroscopic result is a special case of non-linear diffusion described by a superfast diffusion equation (SFDE) for saturation with distinctive mathematical character. We obtain solutions to a moving boundary problem defined by SFDE that robustly convey a time power law of spreading as seen in our experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our new molecular understanding of immune priming states that dendritic cell activation is absolutely pivotal for expansion and differentiation of naïve T lymphocytes, and it follows that understanding DC activation is essential to understand and design vaccine adjuvants. This chapter describes how dendritic cells can be used as a core tool to provide detailed quantitative and predictive immunomics information about how adjuvants function. The role of distinct antigen, costimulation, and differentiation signals from activated DC in priming is explained. Four categories of input signals which control DC activation – direct pathogen detection, sensing of injury or cell death, indirect activation via endogenous proinflammatory mediators, and feedback from activated T cells – are compared and contrasted. Practical methods for studying adjuvants using DC are summarised and the importance of DC subset choice, simulating T cell feedback, and use of knockout cells is highlighted. Finally, five case studies are examined that illustrate the benefit of DC activation analysis for understanding vaccine adjuvant function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Particulate antigen assemblies in the nanometer range and DNA plasmids are particularly interesting for designing vaccines. We hypothesised that a combination of these approaches could result in a new delivery method of gp160 envelope HIV-1 vaccine which could combine the potency of virus-like particles (VLPs) and the simplicity of use of DNA vaccines. Characterisation of lentivirus-like particles (lentiVLPs) by western blot, dynamic light scattering and electron microscopy revealed that their protein pattern, size and structure make them promising candidates for HIV-1 vaccines. Although all particles were similar with regard to size and distribution, they clearly differed in p24 capsid protein content suggesting that Rev may be required for particle maturation and Gag processing. In vivo, lentiVLP pseudotyping with the gp160 envelope or with a combination of gp160 and VSV-G envelopes did not influence the magnitude of the immune response but the combination of lentiVLPs with Alum adjuvant resulted in a more potent response. Interestingly, the strongest immune response was obtained when plasmids encoding lentiVLPs were co-delivered to mice muscles by electrotransfer, suggesting that lentiVLPs were efficiently produced in vivo or the packaging genes mediate an adjuvant effect. DNA electrotransfer of plasmids encoding lentivirus-like particles offers many advantages and appears therefore as a promising delivery method of HIV-1 vaccines. Keywords:VLP, Electroporation, Electrotransfer, HIV vaccine, DNA vaccine

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work investigated the personal exposure to indoor particulate matters using the intake fraction metric and provided a possible way to trace the particle inhaled from an indoor particle source. A turbulence model validated by the particle measurements in a room with underfloor air distribution (UFAD) system was used to predict the indoor particle concentrations. Inhalation intake fraction of indoor particles was defined and evaluated in two rooms equipped with the UFAD, i.e., the experimental room and a small office. According to the exposure characteristics and a typical respiratory rate, the intake fraction was determined in two rooms with a continuous and episodic (human cough) source of particles, respectively. The findings showed that the well-mixing assumption of indoor air failed to give an accurate estimation of inhalation exposure and the average concentration at return outlet or within the overall room could not relate well the intake fraction to the amount of particle emitted from an indoor source.