4 resultados para pH measurement

em CentAUR: Central Archive University of Reading - UK


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dialysis and ultrafiltration were investigated as methods for measuring pH and ionic calcium and partitioning of divalent cations of milk at high temperatures. It was found that ionic calcium, pH, and total soluble divalent cations decreased as temperature increased between 20 and 80°C in both dialysates and ultrafiltration permeates. Between 90 and 110°C, ionic calcium and pH in dialysates continued to decrease as temperature increased, and the relationship between ionic calcium and temperature was linear. The permeabilities of hydrogen and calcium ions through the dialysis tubing were not changed after the tubing was sterilized for 1h at 120°C. There were no significant differences in pH and ionic calcium between dialysates from raw milk and those from a range of heat-treated milks. The effects of calcium chloride addition on pH and ionic calcium were measured in milk at 20°C and in dialysates collected at 110°C. Heat coagulation at 110°C occurred with addition of calcium chloride at 5.4mM, where pH and ionic calcium of the dialysate were 6.00 and 0.43mM, respectively. Corresponding values at 20°C were pH 6.66 and 2.10mM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we report a new method based on supercritical carbon dioxide (scCO(2)) to fill and distribute the porous magnetic nanoparticles with n-octanol in a homogeneous manner. The high solubility of n-octanol in scCO(2) and high diffusivity and permeability of the fluid allow efficient delivery of n-octanol into the porous magnetic nanoparticles. Thus, the n-octanol-loaded magnetic nanoparticles can be readily dispersed into aqueous buffer (pH 7.40) to form a homogenous suspension consisting of nano-sized n-octanol droplets. We refer this suspension as the n-octanol stock solution. The n-octanol stock solution is then mixed with bulk aqueous phase (pH 7.40) containing an organic compound prior to magnetic separation. The small-size of the particles and the efficient mixing enable a rapid establishment of the partition equilibrium of the organic compound between the solid supported n-octanol nano-droplets and the bulk aqueous phase. UV-vis spectrophotometry is then applied to determine the concentration of the organic compound in the aqueous phase both before and after partitioning (after magnetic separation). As a result, log D values of organic compounds of pharmaceutical interest determined by this modified method are found to be in excellent agreement with the literature data. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are many reports in the literature regarding the effects of ionic calcium on reactions related to casein micelle stability, such as heat stability, ethanol stability and susceptibility to gelation, sediment formation and fouling. However, experimental evidence supporting these assertions is much less readily available. This paper evaluates three selective ion electrode systems for measuring ionic calcium directly in milk as well as looking at the effects on pH reduction and addition of calcium chloride. The best electrode system was the Ciba Corning 634 system, which was designed for blood but has been modified for milk. This was found to be reproducible and stable when calibrated daily and allowed direct measurements to be taken on milk in 70 s. This has been found to perform well now for 3 years. The other systems were not so useful, as they took longer to stabilize, but may be useful for higher ionic calcium concentrations, which are found in acidified milk products. Reducing the pH increased ionic calcium and reduced ethanol stability. Calcium chloride addition reduced pH, increased ionic calcium and reduced the ethanol stability. Readjusting the pH to its value before calcium addition reduced the ionic calcium, but not back to its original value. Milks from individual cows showed wide variations in their ionic calcium concentrations. This establishes the methodology for a more detailed investigation on measurement of ionic calcium in milks from individual cows and from bulk milks, to allow a better understanding of its role in casein micelle stability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Optical characteristics of stirred curd were simultaneously monitored during syneresis in a 10-L cheese vat using computer vision and colorimetric measurements. Curd syneresis kinetic conditions were varied using 2 levels of milk pH (6.0 and 6.5) and 2 agitation speeds (12.1 and 27.2 rpm). Measured optical parameters were compared with gravimetric measurements of syneresis, taken simultaneously. The results showed that computer vision and colorimeter measurements have potential for monitoring syneresis. The 2 different phases, curd and whey, were distinguished by means of color differences. As syneresis progressed, the backscattered light became increasingly yellow in hue for circa 20 min for the higher stirring speed and circa 30 min for the lower stirring speed. Syneresis-related gravimetric measurements of importance to cheese making (e.g., curd moisture content, total solids in whey, and yield of whey) correlated significantly with computer vision and colorimetric measurements..