3 resultados para optical probe

em CentAUR: Central Archive University of Reading - UK


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Penetration enhancers are chemicals that temporarily and reversibly diminish the barrier function of the outermost layer of skin, the stratum corneum, to facilitate drug delivery to and through the tissue. In the current study, the complex mechanisms by which 1,8-cineole, a potent terpene penetration enhancer, disrupts the stratum corneum barrier is investigated using post-mortem skin samples. In order to validate the use of excised tissue for these and related studies, a fibre optical probe coupled to an FT-Raman spectrometer compared spectroscopic information for human skin recorded from in vivo and in vitro sampling arrangements. Spectra from full-thickness (epidermis and dermis) post-mortem skin samples presented to the spectrometer with minimal sample preparation (cold acetone rinse) were compared with the in vivo system (the forearms of human volunteers). No significant differences in the Raman spectra between the in vivo and in vitro samples were observed, endorsing the use of post-mortem or surgical samples for this investigational work. Treating post-mortem samples with the penetration enhancer revealed some unexpected findings: while evidence for enhancer-induced disruption of the barrier lipid packing in the stratum corneum was detected in some samples, spectra from other samples revealed an increase in lipid order on treatment with the permeation promoter. These findings are consistent with phase-separation of the enhancer within the barrier lipid domains as opposed to homogeneous disruption of the lipid lamellae. Copyright (C) 2006 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new automatic feedback potometer for physiological studies of water uptake by root systems is described. A dual-optical-fibre amplitude-modulating displacement transducer of improved sensitivity is employed to detect the changes in liquid level. The merits of optimal double-cut fibres, which make full use of the critical angle and improve coupling between the emitter and the receiver, have resulted in a sensor that is 64 times more responsive than the simple emitter - detector probe. Positioning the optical fibre transducer in a narrow capillary and using feedback to control the liquid level allows continuous measurement of volumes in the nanolitre range. The optical sensor used does not need re-calibration for the different salt solutions used in such studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Experimental results of the temperature dependence of the nonlinear optical response of methyl red doped polymethylmethacrylate films in the range 20°C to 170°C are reported. It is found that the intensity of the phase conjugate signal resulting from degenerate four-wave mixing using pump and probe beams with parallel polarisation states increases dramatically on heating by a factor of ∼ 10, reaching a maximum at ∼ 100°C. The intensity of the phase conjugate signal for the case with crossed polarisation states of the pump and probe beams drops monotonically with increasing temperature. For both configurations the response time shortens with increasing temperature. The particular role of the polymer matrix in this temperature variation of the nonlinear optical response is discussed.