10 resultados para non-content method

em CentAUR: Central Archive University of Reading - UK


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a remote sensing method for measuring the internal interface height field in a rotating, two-layer annulus laboratory experiment. The method is non-invasive, avoiding the possibility of an interaction between the flow and the measurement device. The height fields retrieved are accurate and highly resolved in both space and time. The technique is based on a flow visualization method developed by previous workers, and relies upon the optical rotation properties of the working liquids. The previous methods returned only qualitative interface maps, however. In the present study, a technique is developed for deriving quantitative maps by calibrating height against the colour fields registered by a camera which views the flow from above. We use a layer-wise torque balance analysis to determine the equilibrium interface height field analytically, in order to derive the calibration curves. With the current system, viewing an annulus of outer radius 125 mm and depth 250 mm from a distance of 2 m, the inferred height fields have horizontal, vertical and temporal resolutions of up to 0.2 mm, 1 mm and 0.04 s, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a software-based study of a hardware-based non-sorting median calculation method on a set of integer numbers. The method divides the binary representation of each integer element in the set into bit slices in order to find the element located in the middle position. The method exhibits a linear complexity order and our analysis shows that the best performance in execution time is obtained when slices of 4-bit in size are used for 8-bit and 16-bit integers, in mostly any data set size. Results suggest that software implementation of bit slice method for median calculation outperforms sorting-based methods with increasing improvement for larger data set size. For data set sizes of N > 5, our simulations show an improvement of at least 40%.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The effect of temperature on the degradation of blackcurrant anthocyanins in a model juice system was determined over a temperature range of 4–140 °C. The thermal degradation of anthocyanins followed pseudo first-order kinetics. From 4–100 °C an isothermal method was used to determine the kinetic parameters. In order to mimic the temperature profile in retort systems, a non-isothermal method was applied to determine the kinetic parameters in the model juice over the temperature range 110–140 °C. The results from both isothermal and non-isothermal methods fit well together, indicating that the non-isothermal procedure is a reliable mathematical method to determine the kinetics of anthocyanin degradation. The reaction rate constant (k) increased from 0.16 (±0.01) × 10−3 to 9.954 (±0.004) h−1 at 4 and 140 °C, respectively. The temperature dependence of the rate of anthocyanin degradation was modelled by an extension of the Arrhenius equation, which showed a linear increase in the activation energy with temperature.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bank of England notes of £20 denomination have been studied using infrared spectroscopy in order to generate a method to identify forged notes. An aim of this work was to develop a non-destructive method so that a small, compact Fourier transform infrared spectrometer (FT-IR) instrument could be used by bank workers, police departments or others such as shop assistants to identify forged notes in a non-lab setting. The ease of use of the instrument is the key to this method, as well as the relatively low cost. The presence of a peak at 1400 cm−1 arising from νasym () from the blank paper section of a forged note proved to be a successful indicator of the note’s illegality for the notes that we studied. Moreover, differences between the spectra of forged and genuine £20 notes were observed in the ν(OH) (ca. 3500 cm−1), ν(CH) (ca. 2900 cm−1) and ν(CO) (ca. 1750 cm−1) regions of the IR spectrum recorded for the polymer film covering the holographic strip. In cases where these simple tests fail, we have shown how an infrared microscope can be used to further differentiate genuine and forged banknotes by producing infrared maps of selected areas of the note contrasting inks with background paper.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A study was designed to examine the relationships between protein, condensed tannin and cell wall carbohydrate content and composition and the nutritional quality of seven tropical legumes (Desmodium ovalifolium, Flemingia macrophylla, Leucaena leucocephala, L pallida, L macrophylla, Calliandra calothyrsus and Clitotia fairchildiana). Among the legume species studied, D ovalifolium showed the lowest concentration of nitrogen, while L leucocephala showed the highest. Fibre (NDF) content was lowest in C calothyrsus, L Leucocephala and L pallida and highest in L macrophylla, which had no measurable condensed tannins. The highest tannin concentration was found in C calothyrsus. Total non-structural polysaccharides (NSP) varied among legumes species (lowest in C calothyrsus and highest in D ovalifolium), and glucose and uronic acids were the most abundant carbohydrate constituents in all legumes. Total NSP losses were lowest in F macrophylla and highest in L leucocephala and L pallida. Gas accumulation and acetate and propionate levels were 50% less with F macrophylla and D ovalifolium as compared with L leucocephala. The highest levels of branched-chain fatty acids were observed with non-tanniniferous legumes, and negative concentrations were observed with some of the legumes with high tannin content (D ovalifolium and F macrophylla). Linear regression analysis showed that the presence of condensed tannins was more related to a reduction of the initial rate of gas production (0-48 h) than to the final amount of gas produced or the extent (144h) of dry matter degradation, which could be due to differences in tannin chemistry. Consequently, more attention should be given in the future to elucidating the impact of tannin structure on the nutritional quality of tropical forage legumes. (C) 2003 Society of Chemical Industry.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A simple general route of obtaining very stable octacoordinated non-oxovanadium( IV) complexes of the general formula VL2 (where H2L is a tetradentate ONNO donor) is presented. Six such complexes (1-6) are adequately characterized by elemental analysis, mass spectrometry, and various spectroscopic techniques. One of these compounds (1) has been structurally characterized. The molecule has crystallographic 4 symmetry and has a dodecahedral structure existing in a tetragonal space group P4n2. The non-oxo character and VL2 stoichiometry for all of the complexes are established from analytical and mass spectrometric data. In addition, the non-oxo character is clearly indicated by the complete absence of the strong nu(v=o) band in the 925-1025 cm(-1) region, which is a signature of all oxovanadium species. The complexes are quite stable in open air in the solid state and in solution, a phenomenon rarely observed in non-oxovanadium(IV) or bare vanadium(IV) complexes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Quality control on fruits requires reliable methods, able to assess with reasonable accuracy and possibly in a non-destructive way their physical and chemical characteristics. More specifically, a decreased firmness indicates the presence of damage or defects in the fruit or else that the fruit has exceeded its “best before date”, becoming unsuitable for consumption. In high-value exotic fruits, such as mangoes, where firmness cannot be easily measured from a simple observation of texture, colour changes and unevenness of fruits surface, the use of non-destructive techniques is highly recommendable. In particular, the application of Laser vibrometry, based on the Doppler effect, a non-contact technique sensitive to differences in displacements inferior to the nanometre, appears ideal for a possible on-line control on food. Previous results indicated that a phase shift can be in a repeatable way associated with the presence of damage on the fruit, whilst a decreased firmness results in significant differences in the displacement of the fruits under the same excitation signal. In this work, frequency ranges for quality control via the application of a sound chirp are suggested, based on the measurement of the signal coherence. The variations of the average vibration spectrum of a grid of points, or of point-by-point signal velocity allows the go-no go recognition of “firm” and “over-ripe” fruits, with notable success in the particular case of mangoes. The future exploitation of this work will include the application of this method to allow on-line control during conveyor belt distribution of fruits.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mechanisms underlying milk fat conjugated linoleic acid (CLA) responses to supplements of fish oil were investigated using five lactating cows each fitted with a rumen cannula in a simple experiment consisting of two consecutive 14-day experimental periods. During the first period cows were offered 18 kg dry matter (DM) per day of a basal (B) diet formulated from grass silage and a cereal based-concentrate (0.6 : 0.4; forage : concentrate ratio, on a DM basis) followed by the same diet supplemented with 250 g fish oil per day (FO) in the second period. The flow of non-esterified fatty acids leaving the rumen was measured using the omasal sampling technique in combination with a triple indigestible marker method based on Li-Co-EDTA, Yb-acetate and Cr-mordanted straw. Fish oil decreased DM intake and milk yield, but had no effect on milk constituent content. Milk fat trans-11C(18:1), total trans-C-18:1, cis-9 trans-11 CLA, total CLA, C-18 :2 (n- 6) and total C-18:2 content were increased in response to fish oil from 1.80, 4.51, 0.39, 0. 56, 0.90 and 1.41 to 9.39, 14.39, 1.66, 1.85, 1.25 and 4.00 g/100 g total fatty acids, respectively. Increases in the cis-9, trans-11 isomer accounted for proportionately 0.89 of the CLA response to fish oil. Furthermore, fish oil decreased the flow of C-18:0 (283 and 47 g/day for B and FO, respectively) and increased that of trans-C-18:1 fatty acids entering the omasal canal (38 and 182 g/day). Omasal flows of trans-C-18:1 acids with double bonds in positions from delta-4 to -15 inclusive were enhanced, but the effects were isomer dependent and primarily associated with an increase in trans-11C(18:1) leaving the rumen (17.1 and 121.1 g/day for B and FO, respectively). Fish oil had no effect on total (4.36 and 3.50 g/day) or cis-9, trans-11 CLA (2.86 and 2.08 g/day) entering the omasal canal. Flows of cis-9, trans-11 CLA were lower than the secretion of this isomer in milk. Comparison with the transfer of the trans-9, trans-11 isomer synthesized in the rumen suggested that proportionately 0.66 and 0.97 of cis-9, trans-11 CLA was derived from endogenous conversion of trans-11 C-18:1 in the mammary gland for B and FO, respectively. It is concluded that fish oil enhances milk fat cis-9, trans-11 CLA content in response to increased supply of trans-11 C-18:1 that arises from an inhibition of trans C-18:1 reduction in the rumen.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Accurate calibration of a head mounted display (HMD) is essential both for research on the visual system and for realistic interaction with virtual objects. Yet, existing calibration methods are time consuming and depend on human judgements, making them error prone. The methods are also limited to optical see-through HMDs. Building on our existing HMD calibration method [1], we show here how it is possible to calibrate a non-see-through HMD. A camera is placed inside an HMD displaying an image of a regular grid, which is captured by the camera. The HMD is then removed and the camera, which remains fixed in position, is used to capture images of a tracked calibration object in various positions. The locations of image features on the calibration object are then re-expressed in relation to the HMD grid. This allows established camera calibration techniques to be used to recover estimates of the display’s intrinsic parameters (width, height, focal length) and extrinsic parameters (optic centre and orientation of the principal ray). We calibrated a HMD in this manner in both see-through and in non-see-through modes and report the magnitude of the errors between real image features and reprojected features. Our calibration method produces low reprojection errors and involves no error-prone human measurements.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Accurate calibration of a head mounted display (HMD) is essential both for research on the visual system and for realistic interaction with virtual objects. Yet, existing calibration methods are time consuming and depend on human judgements, making them error prone, and are often limited to optical see-through HMDs. Building on our existing approach to HMD calibration Gilson et al. (2008), we show here how it is possible to calibrate a non-see-through HMD. A camera is placed inside a HMD displaying an image of a regular grid, which is captured by the camera. The HMD is then removed and the camera, which remains fixed in position, is used to capture images of a tracked calibration object in multiple positions. The centroids of the markers on the calibration object are recovered and their locations re-expressed in relation to the HMD grid. This allows established camera calibration techniques to be used to recover estimates of the HMD display's intrinsic parameters (width, height, focal length) and extrinsic parameters (optic centre and orientation of the principal ray). We calibrated a HMD in this manner and report the magnitude of the errors between real image features and reprojected features. Our calibration method produces low reprojection errors without the need for error-prone human judgements.