13 resultados para format-compliant

em CentAUR: Central Archive University of Reading - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pesticide residue in vegetables is a major food safety issue in Thailand. A range of vegetable products (organic/pesticide-free/ hydroponic) has emerged in Thai markets that guarantee compliance with maximum residue limits. The Government of Thailand is eager to extend the benefits of this suite of alternative vegetables to the entire population, particularly the semi-urban/rural segments that are often bypassed by such speciality products. However, little information is available to guide such an effort, particularly with regard to up-country consumer attitudes, shopping and consumption habits and willingness to pay premiums for such produce. This research aims to fill this gap in knowledge. It reports the results of a survey of vegetable consumption and shopping habits and attitudes of 608 consumers in northeast Thailand. Willingness to pay premiums for pesticide residue limit compliant vegetables is also assessed by using a contingent valuation method, and determinants of willingness to pay are examined using an ordered probit empirical model. Results indicate that, given adequate awareness of relative risks, even up-country consumers are willing to pay market premium levels for these products, and that inadequate availability, rather than lack of demand is the constraining factor. Willingness to pay is found to increase with income, age and supermarket sourcing of vegetables. We also discuss the challenge of improving availability at mainstream outlets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to ease control, the links between actuators and robotic limbs are generally made to be as stiff as possible. This is in contrast to natural limbs, where compliance is present. Springs have been added to the drive train between the actuator and load to imitate this natural compliance. The majority of these springs have been in series between the actuator and load. However, a more biologically inspired approach is taken, here springs have been used in parallel to oppose each other. The paper will describe the application of parallel extension springs in a robot arm in order to give it compliance. Advantages and disadvantages of this application are discussed along with various control strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is common to make the links between actuators and robotic limbs as stiff as possible, in complete contrast to natural systems, where compliance is present. In the past, to create some compliance in a drive, springs have been added to the link between the actuator and load. Many of these springs have been in series with the drive, but recently a more 'biological' approach has been taken where two springs have been used in parallel to counteract each other. This paper describes the application of parallel extension springs in a robot arm in order to give it compliance. Advantages and disadvantages of this application are discussed, along with various control strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 1997, the UK implemented the worlds first commercial digital terrestrial television system. Under the ETS 300 744 standard, the chosen modulation method, COFDM, is assumed to be multipath resilient. Previous work has shown that this is not necessarily the case. It has been shown that the local oscillator required for demodulation from intermediate-frequency to baseband must be very accurate. This paper shows that under multipath conditions, standard methods for obtaining local oscillator phase lock may not be adequate. This paper demonstrates a set of algorithms designed for use with a simple local oscillator circuit which will allow correction for local oscillator phase offset to maintain a low bit error rate with multipath present.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since 1966, coded orthogonal frequency division multiplexing (COFDM) has been investigated to determine the possibility of reducing the overall throughput of a digitally modulated terrestrial television channel. In the investigations, many assumptions have emerged. One common misconception is that in a terrestrial environment, COFDM has an inherent immunity to multipath interference. A theoretical analysis of a multipath channel, along with simulation results has shown that this assumption does not hold the information is considered when including the radio frequency modulation and demodulation. This paper presents a background into the inception of COFDM, a mathematical analysis of the digitally modulated television signal under multipath conditions and the results of a European Digital Video Broadcasting-Terrestrial (DVB-T) compliant simulation model with MPEG-2 bitstreams transmitted under various multipath conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a Dual-Magnet Magnetic Compliance Unit (DMCU) for use in medium sized space rover platforms to enhance terrain handling capabilities and speed of traversal. An explanation of magnetic compliance and how it can be applied to space robotics is shown, along with an initial mathematical model for this system. A design for the DMCU is proposed along with a 4-wheeled DMCU Testing Rig.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neuroprostheses interfaced with transected peripheral nerves are technological routes to control robotic limbs as well as convey sensory feedback to patients suffering from traumatic neural injuries or degenerative diseases. To maximize the wealth of data obtained in recordings, interfacing devices are required to have intrafascicular resolution and provide high signal-to-noise ratio (SNR) recordings. In this paper, we focus on a possible building block of a three-dimensional regenerative implant: a polydimethylsiloxane (PDMS) microchannel electrode capable of highly sensitive recordings in vivo. The PDMS 'micro-cuff' consists of a 3.5 mm long (100 µm × 70 µm cross section) microfluidic channel equipped with five evaporated Ti/Au/Ti electrodes of sub-100 nm thickness. Individual electrodes have average impedance of 640 ± 30 kΩ with a phase angle of −58 ± 1 degrees at 1 kHz and survive demanding mechanical handling such as twisting and bending. In proof-of-principle acute implantation experiments in rats, surgically teased afferent nerve strands from the L5 dorsal root were threaded through the microchannel. Tactile stimulation of the skin was reliably monitored with the three inner electrodes in the device, simultaneously recording signal amplitudes of up to 50 µV under saline immersion. The overall SNR was approximately 4. A small but consistent time lag between the signals arriving at the three electrodes was observed and yields a fibre conduction velocity of 30 m s−1. The fidelity of the recordings was verified by placing the same nerve strand in oil and recording activity with hook electrodes. Our results show that PDMS microchannel electrodes open a promising technological path to 3D regenerative interfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have fabricated a compliant neural interface to record afferent nerve activity. Stretchable gold electrodes were evaporated on a polydimethylsiloxane (PDMS) substrate and were encapsulated using photo-patternable PDMS. The built-in microstructure of the gold film on PDMS allows the electrodes to twist and flex repeatedly, without loss of electrical conductivity. PDMS microchannels (5mm long, 100μm wide, 100μm deep) were then plasma bonded irreversibly on top of the electrode array to define five parallel-conduit implants. The soft gold microelectrodes have a low impedance of ~200kΩ at the 1kHz frequency range. Teased nerves from the L6 dorsal root of an anaesthetized Sprague Dawley rat were threaded through the microchannels. Acute tripolar recordings of cutaneous activity are demonstrated, from multiple nerve rootlets simultaneously. Confinement of the axons within narrow microchannels allows for reliable recordings of low amplitude afferents. This electrode technology promises exciting applications in neuroprosthetic devices including bladder fullness monitors and peripheral nervous system implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examine a classic ‘wheel of retailing’ episode – the abandonment of the five and dime pricing formula by American variety chains. These switched from a conventional product lifecycle, focusing on cost reduction through standardisation, to a reverse path up the ‘service cost - unit value’ continuum. We show that, rather than reflecting deteriorating managerial acumen, this was a response to the continued imperative for growth following retail format saturation. Firm-specific (rather than format-specific) competitive advantages were too weak for any chain to be confident it could win a within-format price war, making inter-format competition through raising price points more attractive.