Passive samplers have been predominantly used to monitor environmental conditions in single volumes. However, measurements using a calibrated passive sampler- Solid Phase Microextraction (SPME) fibre, in three houses with cold pitched roof, successfully demonstrated the potential of the SPME fibre as a device for monitoring air movement in two volumes. The roofs monitored were pitched at 15° - 30° with insulation thickness varying between 200-300 mm on the ceiling. For effective analysis, two constant sources of volatile organic compounds were diffused steadily in the house. Emission rates and air movement from the house to the roof was predicted using developed algorithms. The airflow rates which were calibrated against conventional tracer gas techniques were introduced into a HAM software package to predict the effects of air movement on other varying parameters. On average it was shown from the in situ measurements that about 20-30% of air entering the three houses left through gaps and cracks in the ceiling into the roof. Although these field measurements focus on the airflows, it is associated with energy benefits such that; if these flows are reduced then significantly energy losses would also be reduced (as modelled) consequently improving the energy efficiency of the house. Other results illustrated that condensation formation risks were dependent on the airtightness of the building envelopes including configurations of their roof constructions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We study the global atmospheric budgets of mass, moisture, energy and angular momentum in the latest reanalysis from the European Centre for Medium-Range Weather Forecasts (ECMWF), ERA-Interim, for the period 1989–2008 and compare with ERA-40. Most of the measures we use indicate that the ERA-Interim reanalysis is superior in quality to ERA-40. In ERA-Interim the standard deviation of the monthly mean global dry mass of 0.7 kg m−2 (0.007%) is slightly worse than in ERA-40, and long time-scale variations in dry mass originate predominately in the surface pressure field. The divergent winds are improved in ERA-Interim: the global standard deviation of the time-averaged dry mass budget residual is 10 kg m−2 day−1 and the quality of the cross-equatorial mass fluxes is improved. The temporal variations in the global evaporation minus precipitation (E − P) are too large but the global moisture budget residual is 0.003 kg m−2 day−1 with a spatial standard deviation of 0.3 kg m−2 day−1. Both the E − P over ocean and P − E over land are about 15% larger than the 1.1 Tg s−1 transport of water from ocean to land. The top of atmosphere (TOA) net energy losses are improved, with a value of 1 W m−2, but the meridional gradient of the TOA net energy flux is smaller than that from the Clouds and the Earth's Radiant Energy System (CERES) data. At the surface the global energy losses are worse, with a value of 7 W m−2. Over land however, the energy loss is only 0.5 W m−2. The downwelling thermal radiation at the surface in ERA-Interim of 341 W m−2 is towards the higher end of previous estimates. The global mass-adjusted energy budget residual is 8 W m−2 with a spatial standard deviation of 11 W m−2, and the mass-adjusted atmospheric energy transport from low to high latitudes (the sum for the two hemispheres) is 9.5 PW

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The type and thickness of insulation on the topside horizontal of cold pitched roofs has a significant role in controlling air movement, energy conservation and moisture transfer reduction through the ceiling to the loft (roof void) space. To investigate its importance, a numerical model using a HAM software package on a Matlab platform with a Simulink simulation tool has been developed using insitu measurements of airflows from the dwelling space through the ceiling to the loft of three houses of different configurations and loft space. Considering typical UK roof underlay (i.e. bituminous felt and a vapour permeable underlay), insitu measurements of the 3 houses were tested using a calibrated passive sampling technique. Using the measured airflows, the effect of air movement on three types of roof insulation (i.e. fibreglass, cellulose and foam) was modelled to investigate associated energy losses and moisture transport. The thickness of the insulation materials were varied but the ceiling airtightness and eaves gap size were kept constant. These instances were considered in order to visualize the effects of the changing parameters. In addition, two different roof underlays of varying resistances were considered and compared to access the influence of the underlay, if any, on energy conservation. The comparison of these insulation materials in relation to the other parameters showed that the type of insulation material and thickness, contributes significantly to energy conservation and moisture transfer reduction through the roof and hence of the building as a whole.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The principal driver of nitrogen (N) losses from the body including excretion and secretion in milk is N intake. However, other covariates may also play a role in modifying the partitioning of N. This study tests the hypothesis that N partitioning in dairy cows is affected by energy and protein interactions. A database containing 470 dairy cow observations was collated from calorimetry experiments. The data include N and energy parameters of the diet and N utilization by the animal. Univariate and multivariate meta-analyses that considered both within and between study effects were conducted to generate prediction equations based on N intake alone or with an energy component. The univariate models showed that there was a strong positive linear relationships between N intake and N excretion in faeces, urine and milk. The slopes were 0.28 faeces N, 0.38 urine N and 0.20 milk N. Multivariate model analysis did not improve the fit. Metabolizable energy intake had a significant positive effect on the amount of milk N in proportion to faeces and urine N, which is also supported by other studies. Another measure of energy considered as a covariate to N intake was diet quality or metabolizability (the concentration of metabolizable energy relative to gross energy of the diet). Diet quality also had a positive linear relationship with the proportion of milk N relative to N excreted in faeces and urine. Metabolizability had the largest effect on faeces N due to lower protein digestibility of low quality diets. Urine N was also affected by diet quality and the magnitude of the effect was higher than for milk N. This research shows that including a measure of diet quality as a covariate with N intake in a model of N execration can enhance our understanding of the effects of diet composition on N losses from dairy cows. The new prediction equations developed in this study could be used to monitor N losses from dairy systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Distributed generation plays a key role in reducing CO2 emissions and losses in transmission of power. However, due to the nature of renewable resources, distributed generation requires suitable control strategies to assure reliability and optimality for the grid. Multi-agent systems are perfect candidates for providing distributed control of distributed generation stations as well as providing reliability and flexibility for the grid integration. The proposed multi-agent energy management system consists of single-type agents who control one or more gird entities, which are represented as generic sub-agent elements. The agent applies one control algorithm across all elements and uses a cost function to evaluate the suitability of the element as a supplier. The behavior set by the agent's user defines which parameters of an element have greater weight in the cost function, which allows the user to specify the preference on suppliers dynamically. This study shows the ability of the multi-agent energy management system to select suppliers according to the selection behavior given by the user. The optimality of the supplier for the required demand is ensured by the cost function based on the parameters of the element.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper assesses the impact of the location and configuration of Battery Energy Storage Systems (BESS) on Low-Voltage (LV) feeders. BESS are now being deployed on LV networks by Distribution Network Operators (DNOs) as an alternative to conventional reinforcement (e.g. upgrading cables and transformers) in response to increased electricity demand from new technologies such as electric vehicles. By storing energy during periods of low demand and then releasing that energy at times of high demand, the peak demand of a given LV substation on the grid can be reduced therefore mitigating or at least delaying the need for replacement and upgrade. However, existing research into this application of BESS tends to evaluate the aggregated impact of such systems at the substation level and does not systematically consider the impact of the location and configuration of BESS on the voltage profiles, losses and utilisation within a given feeder. In this paper, four configurations of BESS are considered: single-phase, unlinked three-phase, linked three-phase without storage for phase-balancing only, and linked three-phase with storage. These four configurations are then assessed based on models of two real LV networks. In each case, the impact of the BESS is systematically evaluated at every node in the LV network using Matlab linked with OpenDSS. The location and configuration of a BESS is shown to be critical when seeking the best overall network impact or when considering specific impacts on voltage, losses, or utilisation separately. Furthermore, the paper also demonstrates that phase-balancing without energy storage can provide much of the gains on unbalanced networks compared to systems with energy storage.