97 resultados para controlled ventilation
em CentAUR: Central Archive University of Reading - UK
Resumo:
Three-dimensional computational simulations are performed to examine indoor environment and micro-environment around human bodies in an office in terms of thermal environment and air quality. In this study, personal displacement ventilation (PDV), including two cases with all seats taken and two middle seats taken, is compared with overall displacement ventilation (ODV) of all seats taken under the condition that supply temperature is 24℃ and air change rate is 60 l/s per workstation. When using PDV, temperature stratification, the characteristic of displacement ventilation, is obviously observed at the position of occupant’s head and clearer in the case with all seats taken. Verticalertical ertical temperature temperature temperature temperature temperature differences below height of the head areare under under under 2℃ in two cases in two cases in two cases in two cases in two cases in two cases in two cases in two cases with all seats taken,and the temperature with PDV is higher than that with ODV. Verticalertical ertical temperature temperature temperature temperature temperature temperature difference is under 3 under 3under 3 under 3℃ in the case in the case in the case in the case in the case in the case in the case with two middle seats taken. CO2 concentration is lower th is lower th is lower this lower this lower than 2 g/man 2 g/m an 2 g/man 2 g/man 2 g/man 2 g/m 3 in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. The results indicate that PDV can be used in the room with big change of occupants’ number to satisfy the need of thermal comfort and air quality. When not all seats are taken, designers should increase supply air requirement or reduce its temperature for thermal comfort. INDEX TERMS
Resumo:
Relative humidity (RH) measurements, as derived from wet-bulb and dry-bulb thermometers operated as a psychrometer within a thermometer screen, have limited accuracy because of natural ventilation variations. Standard RH calculations generally assume a fixed screen psychrometer coefficient, but this is too small during poor ventilation. By comparing a reference humidity probe—exposed within a screen containing a psychrometer—with wind-speed measurements under controlled conditions, a wind-speed correction for the screen psychrometer coefficient has been derived and applicable when 2-metre wind speeds fall below 3 ms–1. Applying this to hourly-averaged data reduced the mean moist RH bias of the psychrometer (over the reference probe) from 1.2% to 0.4%, and reduced the inter-quartile range of the RH differences from 2.0% to 0.8%. This correction is particularly amenable to automatic measurement systems.
Resumo:
It is often assumed that ventilation of the atmospheric boundary layer is weak in the absence of fronts, but is this always true? In this paper we investigate the processes responsible for ventilation of the atmospheric boundary layer during a nonfrontal day that occurred on 9 May 2005 using the UK Met Office Unified Model. Pollution sources are represented by the constant emission of a passive tracer everywhere over land. The ventilation processes observed include shallow convection, turbulent mixing followed by large-scale ascent, a sea breeze circulation and coastal outflow. Vertical distributions of tracer are validated qualitatively with AMPEP (Aircraft Measurement of chemical Processing Export fluxes of Pollutants over the UK) CO aircraft measurements and are shown to agree impressively well. Budget calculations of tracers are performed in order to determine the relative importance of these ventilation processes. Coastal outflow and the sea breeze circulation were found to ventilate 26% of the boundary layer tracer by sunset of which 2% was above 2 km. A combination of coastal outflow, the sea breeze circulation, turbulent mixing and large-scale ascent ventilated 46% of the boundary layer tracer, of which 10% was above 2 km. Finally, coastal outflow, the sea breeze circulation, turbulent mixing, large-scale ascent and shallow convection together ventilated 52% of the tracer into the free troposphere, of which 26% was above 2 km. Hence this study shows that significant ventilation of the boundary layer can occur in the absence of fronts (and thus during high-pressure events). Turbulent mixing and convection processes can double the amount of pollution ventilated from the boundary layer.
Resumo:
A wind-tunnel study was conducted to investigate ventilation of scalars from urban-like geometries at neighbourhood scale by exploring two different geometries a uniform height roughness and a non-uniform height roughness, both with an equal plan and frontal density of λ p = λ f = 25%. In both configurations a sub-unit of the idealized urban surface was coated with a thin layer of naphthalene to represent area sources. The naphthalene sublimation method was used to measure directly total area-averaged transport of scalars out of the complex geometries. At the same time, naphthalene vapour concentrations controlled by the turbulent fluxes were detected using a fast Flame Ionisation Detection (FID) technique. This paper describes the novel use of a naphthalene coated surface as an area source in dispersion studies. Particular emphasis was also given to testing whether the concentration measurements were independent of Reynolds number. For low wind speeds, transfer from the naphthalene surface is determined by a combination of forced and natural convection. Compared with a propane point source release, a 25% higher free stream velocity was needed for the naphthalene area source to yield Reynolds-number-independent concentration fields. Ventilation transfer coefficients w T /U derived from the naphthalene sublimation method showed that, whilst there was enhanced vertical momentum exchange due to obstacle height variability, advection was reduced and dispersion from the source area was not enhanced. Thus, the height variability of a canopy is an important parameter when generalising urban dispersion. Fine resolution concentration measurements in the canopy showed the effect of height variability on dispersion at street scale. Rapid vertical transport in the wake of individual high-rise obstacles was found to generate elevated point-like sources. A Gaussian plume model was used to analyse differences in the downstream plumes. Intensified lateral and vertical plume spread and plume dilution with height was found for the non-uniform height roughness
Resumo:
Ventilation of the boundary layer has an important effect on local and regional air quality and is a prerequisite for long-range pollution transport. Once in the free troposphere, pollutants can alter the chemical composition of the troposphere and impact on the Earth's radiative forcing. Idealised baroclinic life cycles, LC1 and LC2, have been simulated in a three-dimensional dry hemispheric model in the presence of boundary-layer turbulent fluxes. A passive tracer is added to the simulations to represent pollution emitted at, or near, the surface. A simple conveyor-belt diagnostic is developed to objectively identify regions of the boundary layer that can be ventilated by either warm or cold conveyor belts. Transport of pollutants within and above the boundary layer is examined on synoptic scales. Three different physical mechanisms are found to interact with each other to ventilate pollutants out of the boundary layer. These mechanisms are turbulent mixing within the boundary layer, horizontal advection due to Ekman convergence and divergence within the boundary layer, and advection by the warm conveyor belt. The mass of tracer ventilated by the two life cycles is remarkably similar given the differences in frontal structure, suggesting that the large-scale baroclinicity is an effective constraint on ventilation.
Resumo:
Point defects in metal oxides such as TiO2 are key to their applications in numerous technologies. The investigation of thermally induced nonstoichiometry in TiO2 is complicated by the difficulties in preparing and determining a desired degree of nonstoichiometry. We study controlled self-doping of TiO2 by adsorption of 1/8 and 1/16 monolayer Ti at the (110) surface using a combination of experimental and computational approaches to unravel the details of the adsorption process and the oxidation state of Ti. Upon adsorption of Ti, x-ray and ultraviolet photoemission spectroscopy (XPS and UPS) show formation of reduced Ti. Comparison of pure density functional theory (DFT) with experiment shows that pure DFT provides an inconsistent description of the electronic structure. To surmount this difficulty, we apply DFT corrected for on-site Coulomb interaction (DFT+U) to describe reduced Ti ions. The optimal value of U is 3 eV, determined from comparison of the computed Ti 3d electronic density of states with the UPS data. DFT+U and UPS show the appearance of a Ti 3d adsorbate-induced state at 1.3 eV above the valence band and 1.0 eV below the conduction band. The computations show that the adsorbed Ti atom is oxidized to Ti2+ and a fivefold coordinated surface Ti atom is reduced to Ti3+, while the remaining electron is distributed among other surface Ti atoms. The UPS data are best fitted with reduced Ti2+ and Ti3+ ions. These results demonstrate that the complexity of doped metal oxides is best understood with a combination of experiment and appropriate computations.
Resumo:
We show that close to monodisperse crystalline fibrils of dibenzylidene sorbitol can be obtained by preparation in a polymeric solvent subjected to extended shear flow.
Resumo:
Case study simulations with idealized tracers have been used to determine the relationship between the dynamics and conceptual representations of different midlatitude frontal systems and the amount, distribution, and time scale of boundary layer ventilation by these systems. The key features of ventilation by a kata– and ana–cold frontal system are found to be quantitatively and also often qualitatively similar to the main ventilation pathways, which are the conveyor belts, cloud head, and other convection. The conveyor belts and cloud head occur within cloud, implying that they can be identified using satellite imagery. Differences in the transport by the two systems can be related to their conceptual representations and include a sensitive dependence on the diurnal cycle for the kata- but not the ana-cold frontal case.
Resumo:
Infants (12 to 17 months) were taught 2 novel words for 2 images of novel objects, by pairing isolated auditory labels with to-be-associated images. Comprehension was tested using a preferential looking task in which the infant was presented with both images together with an isolated auditory label. The auditory label usually, but not always, matched one of the images. Infants looked preferentially at images that matched the auditory stimulus. The experiment controlled within-subjects for both side bias and preference for previously named items. Infants showed learning after 12 presentations of the new words. Evidence is presented that, in certain circumstances, the duration of longest look at a target may be a more robust measure of target preference than overall looking time. The experiment provides support for previous demonstrations of rapid word learning by pre-vocabulary spurt children, and offers some methodological improvements to the preferential looking task.
Resumo:
Thermometer screen properties are poorly characterised at low wind speeds. Temperatures from a large thermometer screen have been compared with those from an automatically shaded open-air fine-wire resistance thermometer. For the majority of 5-minute average measurements obtained between July 2008 and 2009, the screen and fine-wire temperatures agreed closely, with a median difference <0.05◦C. At low wind speeds however, larger temperature differences occurred. When calm (wind speed at 2 metres, u2, ≤ 0.1 m s−1), the difference between screen and open-air temperatures varied from −0.25◦C to +0.87◦C. At night with u2 < 0.5 m s−1, this difference was −0.14◦C to 0.39◦C, and, rarely, up to −0.68◦C to 1.38◦C. At the minimum in the daily temperature cycle, the semi-urban site at Reading had u2 < 1 m s−1 for 52% of the observations 1997–2008, u2 < 0.5 m s−1 for 34% and calm conditions for 20%. Consequently uncertainties in the minimum temperature measurements may arise from poor ventilation, which can propagate through calculations to daily average temperatures. In comparison with the daily minimum temperature, the 0900 UTC synoptic temperature measurement has a much lower abundance (5%) of calm conditions.
Resumo:
Midlatitude cyclones are important contributors to boundary layer ventilation. However, it is uncertain how efficient such systems are at transporting pollutants out of the boundary layer, and variations between cyclones are unexplained. In this study 15 idealized baroclinic life cycles, with a passive tracer included, are simulated to identify the relative importance of two transport processes: horizontal divergence and convergence within the boundary layer and large-scale advection by the warm conveyor belt. Results show that the amount of ventilation is insensitive to surface drag over a realistic range of values. This indicates that although boundary layer processes are necessary for ventilation they do not control the magnitude of ventilation. A diagnostic for the mass flux out of the boundary layer has been developed to identify the synoptic-scale variables controlling the strength of ascent in the warm conveyor belt. A very high level of correlation (R-2 values exceeding 0.98) is found between the diagnostic and the actual mass flux computed from the simulations. This demonstrates that the large-scale dynamics control the amount of ventilation, and the efficiency of midlatitude cyclones to ventilate the boundary layer can be estimated using the new mass flux diagnostic. We conclude that meteorological analyses, such as ERA-40, are sufficient to quantify boundary layer ventilation by the large-scale dynamics.
Resumo:
Objective: To evaluate CBTp delivered by non-expert therapists, using CBT relevant measures. Methods: Participants (N=74) were randomised into immediate therapy or waiting list control groups. The therapy group was offered six months of therapy and followed up three months later. The waiting list group received therapy after waiting nine months (becoming the delayed therapy group). Results: Depression improved in the combined therapy group at both the end of therapy and follow-up. Other significant effects were found in only one of the two therapy groups (positive symptoms; cognitive flexibility; uncontrollability of thoughts) or one of the two timepoints (end of therapy: PANSS general symptoms, anxiety, suicidal ideation, social functioning, resistance to voices; follow-up: power beliefs about voices, negative symptoms). There was no difference in costs between the groups. Conclusions: The only robust improvement was in depression. Nevertheless, there were further encouraging but modest improvements in both emotional and cognitive variables, in addition to psychotic symptoms.
Resumo:
Background: The objective was to evaluate the efficacy and tolerability of donepezil (5 and 10 mg/day) compared with placebo in alleviating manifestations of mild to moderate Alzheimer's disease (AD). Method: A systematic review of individual patient data from Phase II and III double-blind, randomised, placebo-controlled studies of up to 24 weeks and completed by 20 December 1999. The main outcome measures were the ADAS-cog, the CIBIC-plus, and reports of adverse events. Results: A total of 2376 patients from ten trials were randomised to either donepezil 5 mg/day (n = 821), 10 mg/day (n = 662) or placebo (n = 893). Cognitive performance was better in patients receiving donepezil than in patients receiving placebo. At 12 weeks the differences in ADAS-cog scores were 5 mg/day-placebo: - 2.1 [95% confidence interval (CI), - 2.6 to - 1.6; p < 0.001], 10 mg/day-placebo: - 2.5 ( - 3.1 to - 2.0; p < 0.001). The corresponding results at 24 weeks were - 2.0 ( - 2.7 to - 1.3; p < 0.001) and - 3.1 ( - 3.9 to - 2.4; p < 0.001). The difference between the 5 and 10 mg/day doses was significant at 24 weeks (p = 0.005). The odds ratios (OR) of improvement on the CIBIC-plus at 12 weeks were: 5 mg/day-placebo 1.8 (1.5 to 2.1; p < 0.001), 10 mg/day-placebo 1.9 (1.5 to 2.4; p < 0.001). The corresponding values at 24 weeks were 1.9 (1.5 to 2.4; p = 0.001) and 2.1 (1.6 to 2.8; p < 0.001). Donepezil was well tolerated; adverse events were cholinergic in nature and generally of mild severity and brief in duration. Conclusion: Donepezil (5 and 10 mg/day) provides meaningful benefits in alleviating deficits in cognitive and clinician-rated global function in AD patients relative to placebo. Increased improvements in cognition were indicated for the higher dose. Copyright © 2004 John Wiley & Sons, Ltd.
Resumo:
Objective: Evaluation of selective decontamination of the digestive tract (SDD) on late mortality in ventilated trauma patients in an intensive care unit (ICU). Methods: A multicenter, randomized controlled trial was undertaken in 401 trauma patients with Hospital Trauma Index-Injury Severity Score of 16 or higher. Patients were randomized to control (n = 200) or SDD (n = 201), using polymyxin E, tobramycin, and amphotericin B in throat and gut throughout ICU treatment combined with cefotaxime for 4 days. Primary endpoint was late mortality excluding early death from hemorrhage or craniocerebral injury. Secondary endpoints were infection and organ dysfunction. Results: Mortality was 20.9% with SDD and 22.0% in controls. Overall late mortality was 15.3% (57/372) as 29 patients died from cerebral injury, 16 SDD and 13 control. The odds ratio (95% confidence intervals) of late mortality for SDD relative to control was 0.75 (0.40-1.37), corresponding to estimates of 13.4% SDD and 17.2% control. The overall infection rate was reduced in the test group (48.8% vs. 61.0%). SDD reduced lower airway infections (30.9% vs. 50.0%) and bloodstream infections due to aerobic Gram-negative bacilli (2.5% vs. 7.5%). No difference in organ dysfunction was found. Concluson: This study demonstrates that SDD significantly reduces infection in multiple trauma, although this RCT in 401 patients was underpowered to detect a mortality benefit.