8 resultados para biomechanical

em CentAUR: Central Archive University of Reading - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. Theoretic modeling and experimental studies suggest that functional electrical stimulation (FES) can improve trunk balance in spinal cord injured subjects. This can have a positive impact on daily life, increasing the volume of bimanual workspace, improving sitting posture, and wheelchair propulsion. A closed loop controller for the stimulation is desirable, as it can potentially decrease muscle fatigue and offer better rejection to disturbances. This paper proposes a biomechanical model of the human trunk, and a procedure for its identification, to be used for the future development of FES controllers. The advantage over previous models resides in the simplicity of the solution proposed, which makes it possible to identify the model just before a stimulation session ( taking into account the variability of the muscle response to the FES). Materials and Methods. The structure of the model is based on previous research on FES and muscle physiology. Some details could not be inferred from previous studies, and were determined from experimental data. Experiments with a paraplegic volunteer were conducted in order to measure the moments exerted by the trunk-passive tissues and artificially stimulated muscles. Data for model identification and validation also were collected. Results. Using the proposed structure and identification procedure, the model could adequately reproduce the moments exerted during the experiments. The study reveals that the stimulated trunk extensors can exert maximal moment when the trunk is in the upright position. In contrast, previous studies show that able-bodied subjects can exert maximal trunk extension when flexed forward. Conclusions. The proposed model and identification procedure are a successful first step toward the development of a model-based controller for trunk FES. The model also gives information on the trunk in unique conditions, normally not observable in able-bodied subjects (ie, subject only to extensor muscles contraction).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The tensile strength of 576 pieces of white line horn collected over 6 mo from 14 dairy cows restricted to parity 1 or 2 was tested. None of the cows had ever been lame. Seven cows were randomly assigned to receive 20 mg/d biotin supplementation, and 7 were not supplemented. Hoof horn samples were taken from zones 2 and 3 (the more proximal and distal sites of the abaxial white line) of the medial and lateral claws of both hind feet on d 1 and on 5 further occasions over 6 mo. The samples were analyzed at 100% water saturation. Hoof slivers were notched to ensure that tensile strength was measured specifically across the white line region. The tensile stress at failure was measured in MPa and was adjusted for the cross-sectional area of the notch site. Data were analyzed in a multilevel model, which accounted for the repeated measures within cows. All other variables were entered as fixed effects. In the final model, there was considerable variation in strength over time. Tensile strength was significantly higher in medial compared with lateral claws, and zone 2 was significantly stronger than zone 3. Where the white line was visibly damaged the tensile strength was low. Biotin supplementation did not affect the tensile strength of the white line. Results of this study indicate that damage to the white line impairs its tensile strength and that in horn with no visible abnormality the white line is weaker in the lateral hind claw than the medial and in zone 3 compared with zone 2. The biomechanical strength was lowest at zone 3 of the lateral hind claw, which is the most common site of white line disease lameness in cattle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present results on the growth of damage in 29 fatigue tests of human femoral cortical bone from four individuals, aged 53–79. In these tests we examine the interdependency of stress, cycles to failure, rate of creep strain, and rate of modulus loss. The behavior of creep rates has been reported recently for the same donors as an effect of stress and cycles (Cotton, J. R., Zioupos, P., Winwood, K., and Taylor, M., 2003, "Analysis of Creep Strain During Tensile Fatigue of Cortical Bone," J. Biomech. 36, pp. 943–949). In the present paper we first examine how the evolution of damage (drop in modulus per cycle) is associated with the stress level or the "normalized stress" level (stress divided by specimen modulus), and results show the rate of modulus loss fits better as a function of normalized stress. However, we find here that even better correlations can be established between either the cycles to failure or creep rates versus rates of damage than any of these three measures versus normalized stress. The data indicate that damage rates can be excellent predictors of fatigue life and creep strain rates in tensile fatigue of human cortical bone for use in practical problems and computer simulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we focused on the differences of mechanical properties of tension and normal wood of 1-year-old poplar trees, artificially tilted. Elastic and fracture properties have been measured and linked to the anatomy. Tension wood is well known because it prevents good surface finishing and leads to difficulties with sawing. We studied three main mechanical properties: young modulus, energy of cutting and longitudinal residual strain of maturation (with strain gauges) because of their importance in wood technology. Moreover, this work takes place in a larger project of study, the phenomena of axes re-orientation in trees (allowing by the production of reaction wood), where these data are required for biomechanical modelling. The results show that tension wood has a higher young modulus, needs a higher energy to be cut and exhibited a higher level of longitudinal residual strain of maturation than those of normal wood. The results suggest that these differences require deeper analysis of the wood than anatomy: measurement of microfibril orientation in the S2 layer and also the lignin composition in monomeric units.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pre-term birth is the leading cause of perinatal and neonatal mortality, 40% of which are attributed to the pre-term premature rupture of amnion. Rupture of amnion is thought to be associated with a corresponding decrease in the extracellular collagen content and/or increase in collagenase activity. However, there is very little information concerning the detailed organisation of fibrillar collagen in amnion and how this might influence rupture. Here we identify a loss of lattice like arrangement in collagen organisation from areas near to the rupture site, and present a 9% increase in fibril spacing and a 50% decrease in fibrillar organisation using quantitative measurements gained by transmission electron microscopy and the novel application of synchrotron X-ray diffraction. These data provide an accurate insight into the biomechanical process of amnion rupture and highlight X-ray diffraction as a new and powerful tool in our understanding of this process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biomechanical properties of squid suckers were studied to provide inspiration for the development of sucker artefacts for a robotic octopus. Mechanical support of the rings found inside squid suckers was studied by bending tests. Tensile tests were carried out to study the maximum possible sucking force produced by squid suckers based on the strength of sucker stalks, normalized by the sucking areas. The squid suckers were also directly tested to obtain sucking forces by a special testing arrangement. Inspired by the squid suckers, three types of sucker artefacts were developed for the arm skin of an octopus inspired robot. The first sucker artefact made of knitted nylon sheet reinforced silicone rubber has the same shape as the squid suckers. Like real squid suckers, this type of artefact also has a stalk that is connected to the arm skin and a ring to give radial support.The second design is a straight cylindrical structure with uniform wall thickness made of silicone rubber. One end of the cylinder is directly connected to the arm skin and the other end is open. The final design of the sucker has a cylindrical base and a concave meniscus top. The meniscus was formed naturally using the surface tension of silicone gel, which leads to a higher level of the liquid around the edge of a container. The wall thickness decreases towards the tip of the sucker opening. Sucking forces of all three types of sucker artefacts were measured. Advantages and isadvantages of each sucker type were discussed. The final design of suckers has been implemented to the arm skin prototypes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wheat gluten proteins, gliadins and glutenins, are of great importance in determining the unique biomechanical properties of wheat. Studies have therefore been carried out to determine their pathways and mechanisms of synthesis, folding, and deposition in protein bodies. In the present work, a set of transgenic wheat lines has been studied with strongly suppressed levels of γ-gliadins and/or all groups of gliadins, using light and fluorescence microscopy combined with immunodetection using specific antibodies for γ-gliadins and HMW glutenin subunits. These lines represent a unique material to study the formation and fusion of protein bodies in developing seeds of wheat. Higher amounts of HMW subunits were present in most of the transgenic lines but only the lines with suppression of all gliadins showed differences in the formation and fusion of the protein bodies. Large rounded protein bodies were found in the wild-type lines and the transgenic lines with reduced levels of γ-gliadins, while the lines with all gliadins down-regulated had protein bodies of irregular shape and irregular formation. The size and number of inclusions, which have been reported to contain triticins, were also higher in the protein bodies in the lines with all the gliadins down-regulated. Changes in the protein composition and PB morphology reported in the transgenic lines with all gliadins down-regulated did not result in marked changes in the total protein content or instability of the different fractions.