6 resultados para Wind resistent design.
em CentAUR: Central Archive University of Reading - UK
Resumo:
A wind catcher/tower natural ventilation system was installed in a seminar room in the building of the School of Construction Management and Engineering, the University of Reading in the UK . Performance was analysed by means of ventilation tracer gas measurements, indoor climate measurements (temperature, humidity, CO2) and occupant surveys. In addition, the potential of simple design tools was evaluated by comparing observed ventilation results with those predicted by an explicit ventilation model and the AIDA implicit ventilation model. To support this analysis, external climate parameters (wind speed and direction, solar radiation, external temperature and humidity) were also monitored. The results showed the chosen ventilation design provided a substantially greater ventilation rate than an equivalent area of openable window. Also air quality parameters stayed within accepted norms while occupants expressed general satisfaction with the system and with comfort conditions. Night cooling was maximised by using the system in combination with openable windows. Comparisons of calculations with ventilation rate measurements showed that while AIDA gave reasonably correlated results with the monitored performance results, the widely used industry explicit model was found to over estimate the monitored ventilation rate.
Resumo:
Purpose – To evaluate the control strategy for a hybrid natural ventilation wind catchers and air-conditioning system and to assess the contribution of wind catchers to indoor air environments and energy savings if any. Design/methodology/approach – Most of the modeling techniques for assessing wind catchers performance are theoretical. Post-occupancy evaluation studies of buildings will provide an insight into the operation of these building components and help to inform facilities managers. A case study for POE was presented in this paper. Findings – The monitoring of the summer and winter month operations showed that the indoor air quality parameters were kept within the design target range. The design control strategy failed to record data regarding the operation, opening time and position of wind catchers system. Though the implemented control strategy was working effectively in monitoring the operation of mechanical ventilation systems, i.e. AHU, did not integrate the wind catchers with the mechanical ventilation system. Research limitations/implications – Owing to short-falls in the control strategy implemented in this project, it was found difficult to quantify and verify the contribution of the wind catchers to the internal conditions and, hence, energy savings. Practical implications – Controlling the operation of the wind catchers via the AHU will lead to isolation of the wind catchers in the event of malfunctioning of the AHU. Wind catchers will contribute to the ventilation of space, particularly in the summer months. Originality/value – This paper demonstrates the value of POE as indispensable tool for FM professionals. It further provides insight into the application of natural ventilation systems in building for healthier indoor environments at lower energy cost. The design of the control strategy for natural ventilation and air-conditioning should be considered at the design stage involving the FM personnel.
Resumo:
Wind catcher systems have been employed in buildings in the Middle East for many centuries and they are known by different names in different parts of the region. Recently there has been an increase in the application of this approach for natural ventilation and passive cooling in the UK and other countries. This paper presents the results of experimental wind tunnel and smoke visualisation testing, combined with CFD modelling, to investigate the performance of the wind catcher. For this purpose, a full-scale commercial system was connected to a test room and positioned centrally in an open boundary wind tunnel. Because much ventilation design involves the use of computational fluid dynamics, the measured performance of the system was also compared against the results of CFD analysis. Configurations included both a heated and unheated space to determine the impact of internal heat sources on airflow rate. Good comparisons between measurement and CFD analysis were obtained. Measurements showed that sufficient air change could be achieved to meet both air quality needs and passive cooling.
Resumo:
The aim of this paper is to illustrate the impact of urban wind environments when assessing the availability of natural ventilation. A numerical study of urban airflow for a complex of five building blocks located at the University of Reading, UK is presented. The computational fluid dynamics software package ANSYS was used to simulate six typical cases of urban wind environments and the potential for natural ventilation assessed. The study highlights the impact of three typical architectural forms (street canyons, semi-enclosures and courtyards) on the local wind environment. Simulation results have also been compared with experimental data collected from six locations on the building complex. The study demonstrates that ventilation strategies formed using regional weather data, may have a propensity to over-estimate the potential for natural ventilation and cooling, due to the impact of urban form which creates a unique microclimate. Characteristics of urban wind flow patterns are presented as a guideline and can be used to assess the design and performance of natural or hybrid ventilation and the opportunity for passive cooling.
Resumo:
This paper presents a numerical study of urban air-flow for a group of five buildings that is located at the University of Reading in the United Kingdom. The airflow around these buildings has been simulated by using ANSYS CFD software package. In this study, the association between certain architectural forms: a street canyon, a semi-closure, and a courtyard-like space in a low-rise building complex, and the wind environment were investigated. The analysis of CFD results has provided detailed information on the wind patterns of these urban built forms. The numerical results have been compared with the experimental measurements within the building complex. The observed characteristics of urban wind pattern with respect to the built structures are presented as a guideline. This information is needed for the design and/or performance assessments of systems such as passive and low energy design approach, a natural or hybrid ventilation, and passive cooling. Also, the knowledge of urban wind patterns allows us to develop better design options for the application of renewable energy technologies within urban environment.
Resumo:
The effect of the surrounding lower buildings on the wind pressure distribution on a high-rise building is investigated by computational fluid dynamics (CFD). When B/H=0.1, it is found that the wind pressure on the windward side was reduced especially on the lower part, but for different layers of surrounding buildings, there was no great difference, which agrees with our previous wind tunnel experiment data. Then we changed the aspect ratio from 0.1 to 2, to represent different airflow regimes: skimming flow (SF), and wake interference (WI). It shows that the average Cp increases when B/H increases. For different air flow regimes, it is found that insignificant difference exists when the number of the building layers is more than 2. From the engineering point of view, it is sufficient to only include the first layer for natural ventilation design by using CFD simulation or wind tunnel experiment.