7 resultados para Vacuum.

em CentAUR: Central Archive University of Reading - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bubble inclusion is one of the fastest growing operations practiced in the food industry. A variety of aerated foods is currently available in supermarkets, and newer products are emerging all the time. This paper aims to combine knowledge on chocolate aeration with studies performed on bubble formation and dispersion characteristics. More specifically, we have investigated bubble formation induced by applying vacuum. Experimental methods to determine gas hold-up (volume fraction of air), bubble section distributions along specific planes, and chocolate rheological properties are presented. This study concludes that decreasing pressures elevate gas hold-up values due to an increase in the number of bubble nuclei being formed and release of a greater volume of dissolved gases. Furthermore, bubbles are observed to be larger at lower pressures for a set amount of gas because the internal pressure needs to be in equilibrium with the surrounding pressures. Temperature-induced changes to the properties of the chocolate have less of an effect on bubble formation. On the other hand, when different fats and emulsifiers are added to a standard chocolate recipe, milk fat was found to increase, significantly, the gas hold-up values and the mean bubble-section diameters. It is hypothesized that this behavior is related to the way milk fats, which contain different fatty acids to cocoa butter, crystallize and influence the setting properties of the final product. It is highlighted that apparent viscosity values at low shear rate, as well as setting behavior, play an important role in terms of bubble formation and entrainment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four protocols involving the application of low pressures, either toward the end of frying or after frying, were investigated with the aim of lowering the oil content of potato chips. Protocol 1 involving frying at atmospheric pressure followed by a 3 min draining time constituted the control. Protocol 2 involved lowering of pressure to 13.33 kPa, 40 s before the end of frying, followed by draining for 3 min at the same pressure. Protocol 3 was the same as protocol 2, except that the pressure was lowered 3 s before the end of frying. Protocol 4 involved lowering the pressure to 13.33 kPa after the product was lifted from the oil and holding it at this value over the draining time of 3 min. Protocol 4 gave a product having the lowest oil content (37.12 g oil/100 g defatted dry matter), while protocol 2 gave the product with highest oil content (71.10 g oil/100 g defatted dry matter), followed by those obtained using protocols 1 and 3(68.48 g oil/100 g defatted dry matter and 52.50 g oil/100 g defatted dry matter, respectively). Protocol 4 was further evaluated to study the effects of draining times and vacuum applied, and compared with the control. It was noted that over the modest range of pressures investigated, there was no significant effect of the vacuum applied on the oil content of the product. This study demonstrates that the oil content of potato chips can be lowered significantly by combining atmospheric frying with draining under vacuum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper represents a study of the transient changes occurring in temperature, and moisture and oil contents during the so called “post-frying drainage”—which is the duration for which a product is held in the head space of the fryer after it is removed from the oil. Since most of the oil adhering to the product penetrates into the structure during this period, this paper examines the effects of applying vacuum during drainage (1.33 kPa) to maintain the product temperature consistently above the water saturation temperature corresponding to the prevailing pressure (11 °C), which potentially eliminates water condensation and prevents the occluded surface oil from penetrating into the product structure. Draining under vacuum significantly lowers the oil content of potato chips by 38% compared to atmospheric drainage. This phenomenon can be further confirmed by confocal laser scanning microscopy (CLSM) images, which show that the boundary between the core and the crust regions is clearly visible in the case of vacuum drainage, whereas in the case of atmospheric drainage, the oil is distributed throughout the structure. Unfortunately, the same approach did not reduce the oil content of French fries—the oil content of vacuum-drained product was found similar to the product obtained by draining under atmospheric pressure. This is because the reduction in oil content only occurs when there is net moisture evaporation from the product and the evaporation rate is sufficient to force out the oil from the product; this was clearly not the case with French fries. The CLSM images show that the oil distribution in the products drained under atmospheric pressure and vacuum was similar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper explores the possibility of combining moderate vacuum frying followed by post-frying high vacuum application during the oil drainage stage, with the aim to reduce oil content in potato chips. Potato slices were initially vacuum fried under two operating conditions (140 °C, 20 kPa and 162 °C, 50.67 kPa) until the moisture content reached 10 and 15 % (wet basis), prior to holding the samples in the head space under high vacuum level (1.33 kPa). This two-stage process was found to lower significantly the amount of oil taken up by potato chips by an amount as high as 48 %, compared to drainage at the same pressure as the frying pressure. Reducing the pressure value to 1.33 kPa reduced the water saturation temperature (11 °C), causing the product to continuously lose moisture during the course of drainage. Continuous release of water vapour prevented the occluded surface oil from penetrating into the product structure and released it from the surface of the product. When frying and drainage occurred at the same pressure, the temperature of the product fell below the water saturation temperature soon after it was lifted out of the oil, which resulted in the oil getting sucked into the product. Thus, lowering the pressure after frying to a value well below the frying pressure is a promising method to lower oil uptake by the product.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the effect of atmospheric frying followed by drainage under vacuum on the stability of oil, compared to similar frying with drainage at atmospheric pressure. Changes in the oil were assessed by the free fatty acid (FFA) content, p-anisidine value (AnV), colour, viscosity, fatty acid profile and concentration of tocols. The rate of FFA formation in the case of vacuum drainage was found to be about half that of atmospheric drainage. Oil deterioration by oxidation and polymerisation was also reduced by the use of vacuum drainage. The AnV of the oil after vacuum drainage was lower by about 12%, the total colour difference was improved by 14% and viscosity was slightly reduced after 5 days of frying, compared to the values for oil that had been drained at atmospheric pressure. There was a reduction in the loss of polyunsaturated fatty acids in the case of vacuum drainage after 5 days of frying but differences in retention of tocols were only evident in the first two days of frying.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a novel extraction device for water and noble gases from speleothem samples for noble gas paleotemperature determination. The “combined vacuum crushing and sieving (CVCS) system” was designed to reduce the atmospheric noble gas contents from air inclusions in speleothem samples by up to 2 orders of magnitude without adsorbing atmospheric noble gases onto the freshly produced grain surfaces, a process that had often hampered noble gas temperature (NGT) determination in the past. We also present the results from first performance tests of the CVCS system processing stalagmite samples grown at a known temperature. This temperature is reliably reproduced by the NGTs derived from Ar, Kr, and Xe extracted from the samples. The CVCS system is, therefore, suitable for routine determinations of accurate NGTs. In combination with stalagmite dating, these NGTs will allow reconstructing past regional temperature evolutions, and also support the interpretation of the often complex stable isotope records preserved in the stalagmites' calcite.