7 resultados para Transducer

em CentAUR: Central Archive University of Reading - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypothesis: The aim of this study was to measure the mass loading effect of an active middle-ear implant (the Vibrant Soundbridge) in cadaver temporal bones. Background: Implantable middle ear hearing devices such as Vibrant Soundbridge have been used as an alternative to conventional hearing aids for the rehabilitation of sensorineural hearing loss. Other than the obvious disadvantage of requiring implantation middle ear surgery, it also applies a direct weight on the ossicular chain which, in turn, may have an impact on residual hearing. Previous studies have shown that applying a mass directly on the ossicular chain has a damping effect on its response to sound. However, little has been done to investigate the magnitude and the frequency characteristics of the mass loading effect in devices such as the Vibrant Soundbridge. Methods: Five fresh cadaver temporal bones were used. The stapes displacement was measured using laser Doppler vibrometry before and after the placement of a Vibrant Sound-bridge floating mass transducer. The effects of mass and attachment site were compared with the unloaded response. Measurements were obtained at frequencies between 0.1 and 10 kHz and at acoustic input levels of 100 dB sound pressure level. Each temporal bone acted as its own control. Results: Placement of the floating mass transducer caused a reduction of the stapes displacement. There were variations between the bones. The change of the stapes displacement varied from 0 dB to 28 dB. The effect was more prominent at frequencies above 1,000 Hz. Placing the floating mass transducer close to the incudostapedial joint reduced the mass loading effect. Conclusion: The floating mass transducer produces a measurable reduction of the stapes displacement in the temporal bone model. The effect is more prominent at high frequencies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A study was conducted to estimate variation among laboratories and between manual and automated techniques of measuring pressure on the resulting gas production profiles (GPP). Eight feeds (molassed sugarbeet feed, grass silage, maize silage, soyabean hulls, maize gluten feed, whole crop wheat silage, wheat, glucose) were milled to pass a I mm screen and sent to three laboratories (ADAS Nutritional Sciences Research Unit, UK; Institute of Grassland and Environmental Research (IGER), UK; Wageningen University, The Netherlands). Each laboratory measured GPP over 144 h using standardised procedures with manual pressure transducers (MPT) and automated pressure systems (APS). The APS at ADAS used a pressure transducer and bottles in a shaking water bath, while the APS at Wageningen and IGER used a pressure sensor and bottles held in a stationary rack. Apparent dry matter degradability (ADDM) was estimated at the end of the incubation. GPP were fitted to a modified Michaelis-Menten model assuming a single phase of gas production, and GPP were described in terms of the asymptotic volume of gas produced (A), the time to half A (B), the time of maximum gas production rate (t(RM) (gas)) and maximum gas production rate (R-M (gas)). There were effects (P<0.001) of substrate on all parameters. However, MPT produced more (P<0.001) gas, but with longer (P<0.001) B and t(RM gas) (P<0.05) and lower (P<0.001) R-M gas compared to APS. There was no difference between apparatus in ADDM estimates. Interactions occurred between substrate and apparatus, substrate and laboratory, and laboratory and apparatus. However, when mean values for MPT were regressed from the individual laboratories, relationships were good (i.e., adjusted R-2 = 0.827 or higher). Good relationships were also observed with APS, although they were weaker than for MPT (i.e., adjusted R-2 = 0.723 or higher). The relationships between mean MPT and mean APS data were also good (i.e., adjusted R 2 = 0. 844 or higher). Data suggest that, although laboratory and method of measuring pressure are sources of variation in GPP estimation, it should be possible using appropriate mathematical models to standardise data among laboratories so that data from one laboratory could be extrapolated to others. This would allow development of a database of GPP data from many diverse feeds. (c) 2005 Published by Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The interaction of the chemokine receptor, CCR5, expressed in recombinant cells, with different G proteins was investigated and CCR5 was found to interact with G(i), G(o) and G(q) species. Interaction with Gi leads to G protein activation, whereas G. does not seem to be activated. Additionally, CCR5 activation also leads to phosphorylation of Janus kinase 2 (JAK2). Activation of JAK2 is independent of Gi or Gq activation. Gi protein activation was not prevented by inhibition of JAK, showing that heterotrimeric G protein activation and activation of the JAK/signal transducer and activator of transcription (STAT) pathway are independent of each other. (C) 2004 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neuroinflammation plays an integral role in the progression of neurodegeneration. In this study we investigated the anti-inflammatory effects of different classes of flavonoids (flavanones, flavanols and anthocyanidins) in primary mixed glial cells. We found that the flavanones naringenin and hesperetin and the flavols (+)-catechin and (-)-epicatechin, but not the anthocyanidins cyanidin and pelargonidin, attenuated LPS/IFN-gamma-induced TNF-alpha production in glial cells. Naringenin also inhibited LPS/IFN-gamma-induced iNOS expression and nitric oxide production in glial cells, thus showing the strongest antiinflammatory activity among all flavonoids tested. Moreover, naringenin protected against inflammatory-induced neuronal death in a primary neuronal-glial co-culture system. Naringenin also inhibited LPS/IFN-gamma-induced p38 mitogen-activated protein kinase (MAPK) phosphorylation and downstream signal transducer and activator of transcription-1 (STAT-1) in LPS/IFN-gamma stimulated primary mixed glial cells. Taken together, our results suggest that naringenin may produce an anti-inflammatory effect in LPS/IFN-gamma stimulated glial cells that may be due to its interaction with p38 signalling cascades and the STAT-I trascription factor. (C) 2009 Elseiver Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Current limitations in piezoelectric and electrostatic transducers are discussed. A force-feedback electrostatic transducer capable of operating at bandwidths up to 20 kHz is described. Advantages of the proposed design are a linearised operation which simplifies the feedback control aspects and robustness of the performance characteristics to environmental perturbations. Applications in nanotechnology, optical sciences and acoustics are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new automatic feedback potometer for physiological studies of water uptake by root systems is described. A dual-optical-fibre amplitude-modulating displacement transducer of improved sensitivity is employed to detect the changes in liquid level. The merits of optimal double-cut fibres, which make full use of the critical angle and improve coupling between the emitter and the receiver, have resulted in a sensor that is 64 times more responsive than the simple emitter - detector probe. Positioning the optical fibre transducer in a narrow capillary and using feedback to control the liquid level allows continuous measurement of volumes in the nanolitre range. The optical sensor used does not need re-calibration for the different salt solutions used in such studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The monitoring of water uptake in plants is becoming increasingly important. Optical sensors offer considerable advantages over conventional methods and several sensors have been developed including an optical potometer that monitors water uptake from individual roots, the detection of xylem cavitation using audio acoustic emissions with an interferometric force feedback microphone, and an optical fiber displacement transducer that detects changes in leaf thickness in relation to leaf-water potential.