7 resultados para THICK ASCENDING LIMBS
em CentAUR: Central Archive University of Reading - UK
Resumo:
Laser beams emitted from the Geoscience Laser Altimeter System (GLAS), as well as other spaceborne laser instruments, can only penetrate clouds to a limit of a few optical depths. As a result, only optical depths of thinner clouds (< about 3 for GLAS) are retrieved from the reflected lidar signal. This paper presents a comprehensive study of possible retrievals of optical depth of thick clouds using solar background light and treating GLAS as a solar radiometer. To do so one must first calibrate the reflected solar radiation received by the photon-counting detectors of the GLAS 532-nm channel, the primary channel for atmospheric products. Solar background radiation is regarded as a noise to be subtracted in the retrieval process of the lidar products. However, once calibrated, it becomes a signal that can be used in studying the properties of optically thick clouds. In this paper, three calibration methods are presented: (i) calibration with coincident airborne and GLAS observations, (ii) calibration with coincident Geostationary Opera- tional Environmental Satellite (GOES) and GLAS observations of deep convective clouds, and (iii) cali- bration from first principles using optical depth of thin water clouds over ocean retrieved by GLAS active remote sensing. Results from the three methods agree well with each other. Cloud optical depth (COD) is retrieved from the calibrated solar background signal using a one-channel retrieval. Comparison with COD retrieved from GOES during GLAS overpasses shows that the average difference between the two retriev- als is 24%. As an example, the COD values retrieved from GLAS solar background are illustrated for a marine stratocumulus cloud field that is too thick to be penetrated by the GLAS laser. Based on this study, optical depths for thick clouds will be provided as a supplementary product to the existing operational GLAS cloud products in future GLAS data releases.
Resumo:
The changes in the optical transparency of PbTe monolayers induced by post-evaporation heat treatment are described. The monolayers are typically a few microns in thickness and heat treatment reduces the carrier density from about 1018 (n-type) per cm3 to 1017 per cm3 : the source material is 1019 (ptype) per cm3. The process seems to involve the diffusion of O2 at a reaction rate equivalent to an energy of 0.83 eV.
Resumo:
The first measurement of the relative permittivity (εr) and loss tangent (tan δ) of EPON™ SU-8 advanced thick film ultraviolet photoresist is reported at frequencies between 75–110 GHz (W-band). The problems associated with such a measurement are discussed, an error analysis given, and values of εr=1.725±0.08 and tanδ =0.02±0.001 are determined.
Resumo:
Recent studies have found contradicting results on whether tropical atmospheric circulation (TAC) has intensified or weakened in recent decades. We here re-investigate recent changes in TAC derived from moisture transports into the tropics using high temporal and spatial resolution reanalyses from ERA-interim. We found a significant strengthening of both, the lower level inward transports and the mid level outward transports over the recent two decades. However the signal in the total budget is weak, because strengthening of the in and outflow neutralize each other, at least to some extent. We found atmospheric humidity to be relatively stable, so suggest that the intensification is mainly caused by an intensification of the wind related circulation strength. The exact quantitative values were found to heavily depend on whether the calculations are based on mean or instantaneous values. We highlight the importance for using the instantaneous ones for transport calculations, as they represent the coincidence of high wind speeds and high atmospheric humidity.
Resumo:
Sensory thresholds are often collected through ascending forced-choice methods. Group thresholds are important for comparing stimuli or populations; yet, the method has two problems. An individual may correctly guess the correct answer at any concentration step and might detect correctly at low concentrations but become adapted or fatigued at higher concentrations. The survival analysis method deals with both issues. Individual sequences of incorrect and correct answers are adjusted, taking into account the group performance at each concentration. The technique reduces the chance probability where there are consecutive correct answers. Adjusted sequences are submitted to survival analysis to determine group thresholds. The technique was applied to an aroma threshold and a taste threshold study. It resulted in group thresholds similar to ASTM or logarithmic regression procedures. Significant differences in taste thresholds between younger and older adults were determined. The approach provides a more robust technique over previous estimation methods.