9 resultados para Surgical Wound Dehiscence

em CentAUR: Central Archive University of Reading - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To assess the potential source of variation that surgeon may add to patient outcome in a clinical trial of surgical procedures. Methods: Two large (n = 1380) parallel multicentre randomized surgical trials were undertaken to compare laparoscopically assisted hysterectomy with conventional methods of abdominal and vaginal hysterectomy; involving 43 surgeons. The primary end point of the trial was the occurrence of at least one major complication. Patients were nested within surgeons giving the data set a hierarchical structure. A total of 10% of patients had at least one major complication, that is, a sparse binary outcome variable. A linear mixed logistic regression model (with logit link function) was used to model the probability of a major complication, with surgeon fitted as a random effect. Models were fitted using the method of maximum likelihood in SAS((R)). Results: There were many convergence problems. These were resolved using a variety of approaches including; treating all effects as fixed for the initial model building; modelling the variance of a parameter on a logarithmic scale and centring of continuous covariates. The initial model building process indicated no significant 'type of operation' across surgeon interaction effect in either trial, the 'type of operation' term was highly significant in the abdominal trial, and the 'surgeon' term was not significant in either trial. Conclusions: The analysis did not find a surgeon effect but it is difficult to conclude that there was not a difference between surgeons. The statistical test may have lacked sufficient power, the variance estimates were small with large standard errors, indicating that the precision of the variance estimates may be questionable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the isolation and characterization of a hitherto unknown gram-negative, rod-shaped Neisseria-like organism from an infected wound resulting from a bite from a kinkajou. Based on both phenotypic and phylogenetic evidence, it is proposed that the unknown organism be classified as a new species, Kingella potus sp. nov.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previously undescribed, Gram-positive, catalase-negative, coccus-shaped organism that originated from a human wound was subjected to taxonomic study. On the basis of its cellular morphology and the results of biochemical testing, the unknown organism was identified tentatively as a member of the genus Helcococcus, but it did not correspond to either of the two recognized species of this genus. Comparative 16S rRNA gene sequencing studies confirmed that the bacterium was associated phylogenetically with the genus Helcococcus, with the unidentified organism forming a hitherto unknown subline within the genus. On the basis of biochemical, molecular chemical and molecular phylogenetic evidence, it is proposed that the unknown organism that was recovered from a human wound should be classified as a novel species of the genus Helcococcus, namely Helcococcus sueciensis sp. nov. The type strain is CCUG 47334(T) ( = CIP 108183(T)).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The possible relationship between nutritional status and clinical outcome following orthopaedic hip surgery was investigated. The nutritional status of 60 elderly female patients admitted for elective total hip replacement (THR) and emergency fractured neck of femur surgery (FNF) was measured over time. Specific measures of clinical outcome, including well-being and functional status, were monitored during hospital stay and at 4, 8 and 26 weeks following discharge. Patients were allocated to a high nutritional risk group where any three of the following were less than the 5th percentile value: serum albumin, haemoglobin, triceps skinfold thickness, mid-upper arm muscle circumference and body weight. Using this definition, malnutrition was present in 4% of THR patients and 41% of FNF patients. It was found that the high risk patients had significantly longer convalescence periods, (median stay27.5 days compared with 0 days, P < 0.0009), and a greater proportion were dependent upon walking frames at 6 months (46% compared with 11%, P < 0.01). Fifty percent of the high risk patients had been living independently prior to admission, in contrast only 29% had returned to their homes at 6 months after discharge. The results indicate an apparent link between clinical outcome and nutritional status based upon the allocation procedure employed, which has the potential for ensuring cost-effective nutritional intervention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

THE clinical skills of medical professionals rely strongly on the sense of touch, combined with anatomical and diagnostic knowledge. Haptic exploratory procedures allow the expert to detect anomalies via gross and fine palpation, squeezing, and contour following. Haptic feedback is also key to medical interventions, for example when an anaesthetist inserts an epidural needle, a surgeon makes an incision, a dental surgeon drills into a carious lesion, or a veterinarian sutures a wound. Yet, current trends in medical technology and training methods involve less haptic feedback to clinicians and trainees. For example, minimally invasive surgery removes the direct contact between the patient and clinician that gives rise to natural haptic feedback, and furthermore introduces scaling and rotational transforms that confuse the relationship between movements of the hand and the surgical site. Similarly, it is thought that computer-based medical simulation and training systems require high-resolution and realistic haptic feedback to the trainee for significant training transfer to occur. The science and technology of haptics thus has great potential to affect the performance of medical procedures and learning of clinical skills. This special section is about understanding

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Feeding damage to plants by insect herbivores induces the production of plant volatiles, which are attractive to the herbivores natural enemies. Little is understood about the plant biochemical pathways involved in aphid-induced plant volatile production. The aphid parasitoid Diaeretiella rapae can detect and respond to aphid-induced volatiles produced by Arabidopsis thaliana. When given experience of those volatiles, it can learn those cues and can therefore be used as a novel biosensor to detect them. The pathways involved in aphid-induced volatile production were investigated by comparing the responses of D. rapae to volatiles from a number of different transgenic mutants of A. thaliana, mutated in their octadecanoid, ethylene or salicylic acid wound-response pathways and also from wild-type plants. Plants were either undamaged or infested by the peach-potato aphid, Myzus persicae. It is demonstrated that the octadecanoid pathway and specifically the COI1 gene are required for aphid-induced volatile production. The presence of salicylic acid is also involved in volatile production. Using this model system, in combination with A. thaliana plants with single point gene mutations, has potential for the precise dissection of biochemical pathways involved in the production of aphid-induced volatiles

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Designing surgical instruments for robotic-assisted minimally-invasive surgery (RAMIS) is challenging due to constraints on the number and type of sensors imposed by considerations such as space or the need for sterilization. A new method for evaluating the usability of virtual teleoperated surgical instruments based on virtual sensors is presented. This method uses virtual prototyping of the surgical instrument with a dual physical interaction, which allows testing of different sensor configurations in a real environment. Moreover, the proposed approach has been applied to the evaluation of prototypes of a two-finger grasper for lump detection by remote pinching. In this example, the usability of a set of five different sensor configurations, with a different number of force sensors, is evaluated in terms of quantitative and qualitative measures in clinical experiments with 23 volunteers. As a result, the smallest number of force sensors needed in the surgical instrument that ensures the usability of the device can be determined. The details of the experimental setup are also included.