9 resultados para SILICONE

em CentAUR: Central Archive University of Reading - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrospinning was used to generate polymer nanofibres from blends of poly-vinyl cinnamate (PVCN) and a cholesteric silicone polymer. Only blends that contained at least 40 % of PVCN produced fibres. Both differential scanning calorimetry and electron dispersion spectroscopy data indicate that the samples are miscible over a wide temperature interval. The variation of fibre diameter with concentration is nonlinear with a well-defined minimum corresponding to an 80 % PVCN blend. The fibres are birefringent with Kerr constants similar to that of cholesteric liquid crystals. Although not significant, the Kerr constant increases with increasing silicone polymer concentration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to develop skin artefact for an octopus-inspired robot arm, which is designed to be able to elongate 60% of its original length, silicone rubber and knitted nylon sheet were selected to manufacture an artificial skin, due to their higher elastic strain and high flexibility. Tensile and scissors cutting tests were conducted to characterise the matrix and reinforcing materials and the skin artefact. Material properties of the individual and the composite materials were compared with the measured properties of real octopus skin presented in Part I. The Young’s modulus of the skin should be below 20 MPa and the elastic strain range should be over 60%. The fracture toughness should be at least 0.9 kJ·m−2. Tubes made of the skin artefact filled with liquid were tested to study volume change under deformation. Finite element analysis model was developed to simulate the material and arm structure under tensile loading. Results show that the skin artefact developed has similar mechanical properties as the real octopus skin and satisfies all the design specifications of the OCTOPUS robot.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Soft skin artefacts made of knitted nylon reinforced silicon rubber were fabricated mimicking octopus skin. A combination of ecoflex 0030 and 0010 were used as matrix of the composite to obtain the right stiffness for the skin artefacts. Material properties were characterised using static uniaxial tension and scissors cutting tests. Two types of tactile sensors were developed to detect normal contact; one used quantum tunnelling composite materials and the second was fabricated from silicone rubber and a conductive textile. Sensitivities of the sensors were tested by applying different modes of loading and the soft sensors were incorporated into the skin prototype. Passive suckers were developed and tested against squid suckers. An integrated skin prototype with embedded deformable sensors and attached suckers developed for the arm of an octopus inspired robot is also presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to fabricate a biomimetic skin for an octopus inspired robot, a new process was developed based on mechanical properties measured from real octopus skin. Various knitted nylon textiles were tested and the one of 10-denier nylon was chosen as reinforcement. A combination of Ecoflex 0030 and 0010 silicone rubbers was used as matrix of the composite to obtain the right stiffness for the skin-analogue system. The open mould fabrication process developed allows air bubble to escape easily and the artificial skin produced was thin and waterproof. Material properties of the biomimetic skin were characterised using static tensile and instrumented scissors cutting tests. The Young’s moduli of the artificial skin are 0.08 MPa and 0.13 MPa in the longitudinal and transverse directions, which are much lower than those of the octopus skin. The strength and fracture toughness of the artificial skin, on the other hand are higher than those of real octopus skins. Conically-shaped skin prototypes to be used to cover the robotic arm unit were manufactured and tested. The biomimetic skin prototype was stiff enough to maintain it conical shape when filled with water. The driving force for elongation was reduced significantly compared with previous prototypes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biomechanical properties of squid suckers were studied to provide inspiration for the development of sucker artefacts for a robotic octopus. Mechanical support of the rings found inside squid suckers was studied by bending tests. Tensile tests were carried out to study the maximum possible sucking force produced by squid suckers based on the strength of sucker stalks, normalized by the sucking areas. The squid suckers were also directly tested to obtain sucking forces by a special testing arrangement. Inspired by the squid suckers, three types of sucker artefacts were developed for the arm skin of an octopus inspired robot. The first sucker artefact made of knitted nylon sheet reinforced silicone rubber has the same shape as the squid suckers. Like real squid suckers, this type of artefact also has a stalk that is connected to the arm skin and a ring to give radial support.The second design is a straight cylindrical structure with uniform wall thickness made of silicone rubber. One end of the cylinder is directly connected to the arm skin and the other end is open. The final design of the sucker has a cylindrical base and a concave meniscus top. The meniscus was formed naturally using the surface tension of silicone gel, which leads to a higher level of the liquid around the edge of a container. The wall thickness decreases towards the tip of the sucker opening. Sucking forces of all three types of sucker artefacts were measured. Advantages and isadvantages of each sucker type were discussed. The final design of suckers has been implemented to the arm skin prototypes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a simple sieving methodology to aid the recovery of large cultigen pollen grains, such as maize (Zea mays L.), manioc (Manihot esculenta Crantz), and sweet potato (Ipomoea batatas L.), among others, for the detection of food production using fossil pollen analysis of lake sediments in the tropical Americas. The new methodology was tested on three large study lakes located next to known and/or excavated pre-Columbian archaeological sites in South and Central America. Five paired samples, one treated by sieving, the other prepared using standard methodology, were compared for each of the three sites. Using the new methodology, chemically digested sediment samples were passed through a 53 µm sieve, and the residue was retained, mounted in silicone oil, and counted for large cultigen pollen grains. The filtrate was mounted and analysed for pollen according to standard palynological procedures. Zea mays (L.) was recovered from the sediments of all three study lakes using the sieving technique, where no cultigen pollen had been previously recorded using the standard methodology. Confidence intervals demonstrate there is no significant difference in pollen assemblages between the sieved versus unsieved samples. Equal numbers of exotic Lycopodium spores added to both the filtrate and residue of the sieved samples allow for direct comparison of cultigen pollen abundance with the standard terrestrial pollen count. Our technique enables the isolation and rapid scanning for maize and other cultigen pollen in lake sediments, which, in conjunction with charcoal and pollen records, is key to determining land-use patterns and the environmental impact of pre-Columbian societies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we present a compliant neural interface designed to record bladder afferent activity. We developed the implant's microfabrication process using multiple layers of silicone rubber and thin metal so that a gold microelectrode array is embedded within four parallel polydimethylsiloxane (PDMS) microchannels (5 mm long, 100 μm wide, 100 μm deep). Electrode impedance at 1 kHz was optimized using a reactive ion etching (RIE) step, which increased the porosity of the electrode surface. The electrodes did not deteriorate after a 3 month immersion in phosphate buffered saline (PBS) at 37 °C. Due to the unique microscopic topography of the metal film on PDMS, the electrodes are extremely compliant and can withstand handling during implantation (twisting and bending) without electrical failure. The device was transplanted acutely to anaesthetized rats, and strands of the dorsal branch of roots L6 and S1 were surgically teased and inserted in three microchannels under saline immersion to allow for simultaneous in vivo recordings in an acute setting. We utilized a tripole electrode configuration to maintain background noise low and improve the signal to noise ratio. The device could distinguish two types of afferent nerve activity related to increasing bladder filling and contraction. To our knowledge, this is the first report of multichannel recordings of bladder afferent activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The loss of motor function at the elbow joint can result as a consequence of stroke. Stroke is a clinical illness resulting in long lasting neurological deficits often affecting somatosensory and motor cortices. More than half of those that recover from a stroke survive with disability in their upper arm and need rehabilitation therapy to help in regaining functions of daily living. In this paper, we demonstrated a prototype of a low-cost, ultra-light and wearable soft robotic assistive device that could aid administration of elbow motion therapies to stroke patients. In order to assist the rotation of the elbow joint, the soft modules which consist of soft wedge-like cellular units was inflated by air to produce torque at the elbow joint. Highly compliant rotation can be naturally realised by the elastic property of soft silicone and pneumatic control of air. Based on the direct visual-actuation control, a higher control loop utilised visual processing to apply positional control, the lower control loop was implemented by an electronic circuit to achieve the desired pressure of the soft modules by Pulse Width Modulation. To examine the functionality of the proposed soft modular system, we used an anatomical model of the upper limb and performed the experiments with healthy participants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to build on the success of in vitro studies of an active packaging, produced by coating the surface of post-consumer recycled polyethylene terephthalate (PCRPET) package with an aqueous silicone solution (2%, v/v) containing an antifungal agent (potassium sorbate, KS). Antifungal efficacy was evaluated, in vivo, during the storage of raspberries, blackberries and blueberries by examining their shelf life extension. The packaging effectively delayed the growth of Botrytis by extending its lag-phase, which, in turn, extended the shelf life of the berries by up to 3d. Among the three berries tested, the packaging proved to be more advantageous in the case of raspberries, due to their physiological characteristics and shorter shelf life. Based on sensory panel evaluations, it was shown that the coating, containing KS, did not influence the packaging appearance and transparency, and the fruit did not suffer from any off-flavor development.