3 resultados para RDF <Informatik>
em CentAUR: Central Archive University of Reading - UK
Resumo:
An experimental method is described which enables the inelastically scattered X-ray component to be removed from diffractometer data prior to radial density function analysis. At each scattering angle an energy spectrum is generated from a Si(Li) detector combined with a multi-channel analyser from which the coherently scattered component is separated. The data obtained from organic polymers has an improved signal/noise ratio at high values of scattering angle, and a commensurate enhancement of resolution of the RDF at low r is demonstrated for the case of PMMA (ICI `Perspex'). The method obviates the need for the complicated correction for multiple scattering.
Resumo:
Information modelling is a topic that has been researched a great deal, but still many questions around it have not been solved. An information model is essential in the design of a database which is the core of an information system. Currently most of databases only deal with information that represents facts, or asserted information. The ability of capturing semantic aspect has to be improved, and yet other types, such as temporal and intentional information, should be considered. Semantic Analysis, a method of information modelling, has offered a way to handle various aspects of information. It employs the domain knowledge and communication acts as sources of information modelling. It lends itself to a uniform structure whereby semantic, temporal and intentional information can be captured, which builds a sound foundation for building a semantic temporal database.
Resumo:
An ozonesonde profile over the Network for Detection of Stratospheric Change (NDSC) site at Lauder (45.0° S, 169.7° E), New Zealand, for 24 December 1998 showed atypically low ozone centered around 24 km altitude (600 K potential temperature). The origin of the anomaly is explained using reverse domain filling (RDF) calculations combined with a PV/O3 fitting technique applied to ozone measurements from the Polar Ozone and Aerosol Measurement (POAM) III instrument. The RDF calculations for two isentropic surfaces, 550 and 600 K, show that ozone-poor air from the Antarctic polar vortex reached New Zealand on 24–26 December 1998. The vortex air on the 550 K isentrope originated in the ozone hole region, unlike the air on 600 K where low ozone values were caused by dynamical effects. High-resolution ozone maps were generated, and their examination shows that a vortex remnant situated above New Zealand was the cause of the altered ozone profile on 24 December. The maps also illustrate mixing of the vortex filaments into southern midlatitudes, whereby the overall mid-latitude ozone levels were decreased.