5 resultados para Quantitative stability
em CentAUR: Central Archive University of Reading - UK
Resumo:
Many pathogens transmit to new hosts by both infection (horizontal transmission) and transfer to the infected host's offspring (vertical transmission). These two transmission modes require speci®c adap- tations of the pathogen that can be mutually exclusive, resulting in a trade-off between horizontal and vertical transmission. We show that in mathematical models such trade-offs can lead to the simultaneous existence of two evolutionary stable states (evolutionary bi-stability) of allocation of resources to the two modes of transmission. We also show that jumping between evolutionary stable states can be induced by gradual environmental changes. Using quantitative PCR-based estimates of abundance in seed and vege- tative parts, we show that the pathogen of wheat, Phaeosphaeria nodorum, has jumped between two distinct states of transmission mode twice in the past 160 years, which, based on published evidence, we interpret as adaptation to environmental change. The ®nding of evolutionary bi-stability has impli- cations for human, animal and other plant diseases. An ill-judged change in a disease control programme could cause the pathogen to evolve a new, and possibly more damaging, combination of transmission modes. Similarly, environmental changes can shift the balance between transmission modes, with adverse effects on human, animal and plant health.
Resumo:
Craloxylum formosum Dyer is consumed throughout the year as food and medicine in Thailand. It contains large amounts of chlorogenic acid and quinic acid derivatives. The antioxidative activity of the extract was studied in refined soybean oil coating on rice crackers without any seasoning. They were stored in accelerated oxidation conditions at 40 degrees C, 80% relative humidity (RH) in the dark for 18 days. The oxidative state of each sample was monitored by analyzing of the peroxide value (PV) and thiobarbituric acid reactive substances (TBARS) as well as by odor analysis by quantitative descriptive analysis (QDA). The C formosum extract was more effective than alpha-tocopherol due to metal ions present in the crackers, which resulted in alpha-tocopherol being less effective as an antioxidant. Sensory odor attributes of rice crackers were related more closely to TBARS than to PV values by linear regression analysis. The present study indicated that C. formosum extract was a promising source of a natural food antioxidant and was effective in inhibiting lipid oxidation in rice crackers.
Resumo:
Two so-called “integrated” polarimetric rate estimation techniques, ZPHI (Testud et al., 2000) and ZZDR (Illingworth and Thompson, 2005), are evaluated using 12 episodes of the year 2005 observed by the French C-band operational Trappes radar, located near Paris. The term “integrated” means that the concentration parameter of the drop size distribution is assumed to be constant over some area and the algorithms retrieve it using the polarimetric variables in that area. The evaluation is carried out in ideal conditions (no partial beam blocking, no ground-clutter contamination, no bright band contamination, a posteriori calibration of the radar variables ZH and ZDR) using hourly rain gauges located at distances less than 60 km from the radar. Also included in the comparison, for the sake of benchmarking, is a conventional Z = 282R1.66 estimator, with and without attenuation correction and with and without adjustment by rain gauges as currently done operationally at Météo France. Under those ideal conditions, the two polarimetric algorithms, which rely solely on radar data, appear to perform as well if not better, pending on the measurements conditions (attenuation, rain rates, …), than the conventional algorithms, even when the latter take into account rain gauges through the adjustment scheme. ZZDR with attenuation correction is the best estimator for hourly rain gauge accumulations lower than 5 mm h−1 and ZPHI is the best one above that threshold. A perturbation analysis has been conducted to assess the sensitivity of the various estimators with respect to biases on ZH and ZDR, taking into account the typical accuracy and stability that can be reasonably achieved with modern operational radars these days (1 dB on ZH and 0.2 dB on ZDR). A +1 dB positive bias on ZH (radar too hot) results in a +14% overestimation of the rain rate with the conventional estimator used in this study (Z = 282R^1.66), a -19% underestimation with ZPHI and a +23% overestimation with ZZDR. Additionally, a +0.2 dB positive bias on ZDR results in a typical rain rate under- estimation of 15% by ZZDR.
Resumo:
The quantitative effects of uniform strain and background rotation on the stability of a strip of constant vorticity (a simple shear layer) are examined. The thickness of the strip decreases in time under the strain, so it is necessary to formulate the linear stability analysis for a time-dependent basic flow. The results show that even a strain rate γ (scaled with the vorticity of the strip) as small as 0.25 suppresses the conventional Rayleigh shear instability mechanism, in the sense that the r.m.s. wave steepness cannot amplify by more than a certain factor, and must eventually decay. For γ < 0.25 the amplification factor increases as γ decreases; however, it is only 3 when γ e 0.065. Numerical simulations confirm the predictions of linear theory at small steepness and predict a threshold value necessary for the formation of coherent vortices. The results help to explain the impression from numerous simulations of two-dimensional turbulence reported in the literature that filaments of vorticity infrequently roll up into vortices. The stabilization effect may be expected to extend to two- and three-dimensional quasi-geostrophic flows.
Resumo:
The Bollène-2002 Experiment was aimed at developing the use of a radar volume-scanning strategy for conducting radar rainfall estimations in the mountainous regions of France. A developmental radar processing system, called Traitements Régionalisés et Adaptatifs de Données Radar pour l’Hydrologie (Regionalized and Adaptive Radar Data Processing for Hydrological Applications), has been built and several algorithms were specifically produced as part of this project. These algorithms include 1) a clutter identification technique based on the pulse-to-pulse variability of reflectivity Z for noncoherent radar, 2) a coupled procedure for determining a rain partition between convective and widespread rainfall R and the associated normalized vertical profiles of reflectivity, and 3) a method for calculating reflectivity at ground level from reflectivities measured aloft. Several radar processing strategies, including nonadaptive, time-adaptive, and space–time-adaptive variants, have been implemented to assess the performance of these new algorithms. Reference rainfall data were derived from a careful analysis of rain gauge datasets furnished by the Cévennes–Vivarais Mediterranean Hydrometeorological Observatory. The assessment criteria for five intense and long-lasting Mediterranean rain events have proven that good quantitative precipitation estimates can be obtained from radar data alone within 100-km range by using well-sited, well-maintained radar systems and sophisticated, physically based data-processing systems. The basic requirements entail performing accurate electronic calibration and stability verification, determining the radar detection domain, achieving efficient clutter elimination, and capturing the vertical structure(s) of reflectivity for the target event. Radar performance was shown to depend on type of rainfall, with better results obtained with deep convective rain systems (Nash coefficients of roughly 0.90 for point radar–rain gauge comparisons at the event time step), as opposed to shallow convective and frontal rain systems (Nash coefficients in the 0.6–0.8 range). In comparison with time-adaptive strategies, the space–time-adaptive strategy yields a very significant reduction in the radar–rain gauge bias while the level of scatter remains basically unchanged. Because the Z–R relationships have not been optimized in this study, results are attributed to an improved processing of spatial variations in the vertical profile of reflectivity. The two main recommendations for future work consist of adapting the rain separation method for radar network operations and documenting Z–R relationships conditional on rainfall type.