5 resultados para Precise Determination

em CentAUR: Central Archive University of Reading - UK


Relevância:

70.00% 70.00%

Publicador:

Resumo:

This contribution describes the optimization of chlorine extraction from silicate samples by pyrohydrolysis prior to the precise determination of Cl stable-isotope compositions (637 Cl) by gas source, dual inlet Isotope Ratio Mass Spectrometry (IRMS) on CH(3)Clg. The complete method was checked on three international reference materials for Cl-content and two laboratory glass standards. Whole procedure blanks are lower than 0. 5 mu mol, corresponding to less than 10 wt.% of most of the sample chloride analysed. In the absence of international chlorine isotope rock, we report here Cl extracted compared to accepted Cl contents and reproducibilities on Cl and delta Cl-37 measurements for the standard rocks. After extraction, the Cl contents of the three international references compared within error with the accepted values (mean yield = 94 +/-10%) with reproducibilities better than 12% (10). The laboratory glass standards - andesite SO100DS92 and phonolite S9(2) - were used specifically to test the effect of chloride amount on the measurements. They gave Cl extraction yields of 100 +/-6% (1 sigma-; n = 15) and 105 +/- 8% (1 sigma-; n = 7), respectively, with delta Cl-37 values of -0.51 0.14%o and -0.39 0.17%o (1g). In summary, for silicate samples with Cl contents between 39 and 9042 ppm, the Pyrohydrolysis/HPLC method leads to overall CI extraction yields of 100 8%, reproducibilities on Cl contents of 7% and on delta Cl-37 measurements of 0.12%o (all 1 sigma). The method was further applied to ten silicate rocks of various mineralogy and chemistry (meteorite, fresh MORB glasses, altered basalts and setpentinized peridotites) chosen for their large range of Cl contents (70-2156 ppm) and their geological significance. delta Cl-37 values range between -2.33 and -0.50%o. These strictly negative values contrast with the large range and mainly positive values previously reported for comparable silicate samples and shown here to be affected by analytical problems. Thus we propose a preliminary, revised terrestrial CI cycle, mainly dominated by negative and zero delta Cl-37 values. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Perchlorate-reducing bacteria fractionate chlorine stable isotopes giving a powerful approach to monitor the extent of microbial consumption of perchlorate in contaminated sites undergoing remediation or natural perchlorate containing sites. This study reports the full experimental data and methodology used to re-evaluate the chlorine isotope fractionation of perchlorate reduction in duplicate culture experiments of Azospira suillum strain PS at 37 degrees C (Delta Cl-37(Cr)--ClO4-) previously reported, without a supporting data set by Coleman et al. [Coleman, M.L., Ader, M., Chaudhuri, S., Coates,J.D., 2003. Microbial Isotopic Fractionation of Perchlorate Chlorine. Appl. Environ. Microbiol. 69, 4997-5000] in a reconnaissance study, with the goal of increasing the accuracy and precision of the isotopic fractionation determination. The method fully described here for the first time, allows the determination of a higher precision Delta Cl-37(Cl)--ClO4- value, either from accumulated chloride content and isotopic composition or from the residual perchlorate content and isotopic composition. The result sets agree perfectly, within error, giving average Delta Cl-37(Cl)--ClO4- = -14.94 +/- 0.15%omicron. Complementary use of chloride and perchlorate data allowed the identification and rejection of poor quality data by applying mass and isotopic balance checks. This precise Delta Cl-37(Cl)--ClO4-, value can serve as a reference point for comparison with future in situ or microcosm studies but we also note its similarity to the theoretical equilibrium isotopic fractionation between a hypothetical chlorine species of redox state +6 and perchlorate at 37 degrees C and suggest that the first electron transfer during perchlorate reduction may occur at isotopic equilibrium between art enzyme-bound chlorine and perchlorate. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Once unit-cell dimensions have been determined from a powder diffraction data set and therefore the crystal system is known (e.g. orthorhombic), the method presented by Markvardsen, David, Johnson & Shankland [Acta Cryst. (2001), A57, 47-54] can be used to generate a table ranking the extinction symbols of the given crystal system according to probability. Markvardsen et al. tested a computer program (ExtSym) implementing the method against Pawley refinement outputs generated using the TF12LS program [David, Ibberson & Matthewman (1992). Report RAL-92-032. Rutherford Appleton Laboratory, Chilton, Didcot, Oxon, UK]. Here, it is shown that ExtSym can be used successfully with many well known powder diffraction analysis packages, namely DASH [David, Shankland, van de Streek, Pidcock, Motherwell & Cole (2006). J. Appl. Cryst. 39, 910-915], FullProf [Rodriguez-Carvajal (1993). Physica B, 192, 55-69], GSAS [Larson & Von Dreele (1994). Report LAUR 86-748. Los Alamos National Laboratory, New Mexico, USA], PRODD [Wright (2004). Z. Kristallogr. 219, 1-11] and TOPAS [Coelho (2003). Bruker AXS GmbH, Karlsruhe, Germany]. In addition, a precise description of the optimal input for ExtSym is given to enable other software packages to interface with ExtSym and to allow the improvement/modification of existing interfacing scripts. ExtSym takes as input the powder data in the form of integrated intensities and error estimates for these intensities. The output returned by ExtSym is demonstrated to be strongly dependent on the accuracy of these error estimates and the reason for this is explained. ExtSym is tested against a wide range of data sets, confirming the algorithm to be very successful at ranking the published extinction symbol as the most likely. (C) 2008 International Union of Crystallography Printed in Singapore - all rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the absence of a suitable method for routine analysis of large numbers of natural river water samples for organic nitrogen and phosphorus fractions, a new simultaneous digestion technique was developed, based on a standard persulphate digestion procedure. This allows rapid analysis of river, lake and groundwater samples from a range of environments for total nitrogen and phosphorus. The method was evaluated using a range of organic nitrogen and phosphorus structures tested at low, mid and high range concentrations from 2 to 50 mg l-1 nitrogen and 0.2 to 10 mg l-1 phosphorus. Mean recoveries for nitrogen ranged from 94.5% (2 mg I-1) to 92.7% (50 mg I-1) and for phosphorus were 98.2% (0.2 mg l-1) to 100.2% (10 mg l-1). The method is precise in its ability m reproduce results from replicate digestions, and robust in its ability to handle a variety of natural water samples in the pH range 5-8.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although the tube theory is successful in describing entangled polymers qualitatively, a more quantitative description requires precise and consistent definitions of its parameters. Here we investigate the simplest model of entangled polymers, namely a single Rouse chain in a cubic lattice of line obstacles, and illustrate the typical problems and uncertainties of the tube theory. In particular we show that in general one needs 3 entanglement related parameters, but only 2 combinations of them are relevant for the long-time dynamics. Conversely, the plateau modulus can not be determined from these two parameters and requires a more detailed model of entanglements with explicit entanglement forces, such as the slipsprings model. It is shown that for the grid model the Rouse time within the tube is larger than the Rouse time of the free chain, in contrast to what the standard tube theory assumes.