4 resultados para Photorefraction

em CentAUR: Central Archive University of Reading - UK


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. Hyperopic retinal defocus (blur) is thought to be a cause of myopia. If the retinal image of an object is not clearly focused, the resulting blur is thought to cause the continuing lengthening of the eyeball during development causing a permanent refractive error. Both lag of accommodation, especially for near targets, and greater variability in the accommodative response, have been suggested as causes of increased hyperopic retinal blur. Previous studies of lag of accommodation show variable findings. In comparison, greater variability in the accommodative response has been demonstrated in adults with late onset myopia but has not been tested in children. This study looked at the lag and variability of accommodation in children with early onset myopia. Methods. Twenty-one myopic and 18 emmetropic children were tested. Dynamic measures of accommodation and pupil size were made using eccentric photorefraction (Power Refractor) while children viewed targets set at three different accommodative demands (0.25, 2, and 4 D). Results. We found no difference in accommodative lag between groups. However, the accommodative response was more variable in the myopes than emmetropes when viewing both the near (4 D) and far (0.25 D) targets. Since pupil size and variability also varied, we analyzed the data to determine whether this could account for the inter-group differences in accommodation variability. Variation in these factors was not found to be sufficient to explain these differences. Changes in the accommodative response variability with target distance were similar to patterns reported previously in adult emmetropes and late onset myopes. Conclusions. Children with early onset myopia demonstrate greater accommodative variability than emmetropic children, and have similar patterns of response to adult late onset myopes. This increased variability could result in an increase in retinal blur for both near and far targets. The role of accommodative variability in the etiology of myopia is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. Accommodation can mask hyperopia and reduce the accuracy of non-cycloplegic refraction. It is, therefore, important to minimize accommodation to obtain a measure of hyperopia as accurate as possible. To characterize the parameters required to measure the maximally hyperopic error using photorefraction, we used different target types and distances to determine which target was most likely to maximally relax accommodation and thus more accurately detect hyperopia in an individual. Methods. A PlusoptiX SO4 infra-red photorefractor was mounted in a remote haploscope which presented the targets. All participants were tested with targets at four fixation distances between 0.3 and 2 m containing all combinations of blur, disparity, and proximity/looming cues. Thirty-eight infants (6 to 44 weeks) were studied longitudinally, and 104 children [4 to 15 years (mean 6.4)] and 85 adults, with a range of refractive errors and binocular vision status, were tested once. Cycloplegic refraction data were available for a sub-set of 59 participants spread across the age range. Results. The maximally hyperopic refraction (MHR) found at any time in the session was most frequently found when fixating the most distant targets and those containing disparity and dynamic proximity/looming cues. Presence or absence of blur was less significant, and targets in which only single cues to depth were present were also less likely to produce MHR. MHR correlated closely with cycloplegic refraction (r = 0.93, mean difference 0.07 D, p = n.s., 95% confidence interval +/-<0.25 D) after correction by a calibration factor. Conclusions. Maximum relaxation of accommodation occurred for binocular targets receding into the distance. Proximal and disparity cues aid relaxation of accommodation to a greater extent than blur, and thus non-cycloplegic refraction targets should incorporate these cues. This is especially important in screening contexts with a brief opportunity to test for significant hyperopia. MHR in our laboratory was found to be a reliable estimation of cycloplegic refraction. (Optom Vis Sci 2009;86:1276-1286)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To investigate the nature of early ocular misalignments in human infants to determine whether they can provide insight into the etiology of esotropia and, in particular, to examine the correlates of misalignments. METHODS. A remote haploscopic photorefraction system was used to measure accommodation and vergence in 146 infants between 0 and 12 months of age. Infants underwent photorefraction immediately after watching a target moving between two of five viewing distances (25, 33, 50, 100, and 200 cm). In some instances, infants were tested in two conditions: both eyes open and one eye occluded. The resultant data were screened for instances of large misalignments. Data were assessed to determine whether accommodative, retinal disparity, or other cues were associated with the occurrence of misalignments. RESULTS. The results showed that there was no correlation between accommodative behavior and misalignments. Infants were more likely to show misalignments when retinal disparity cues were removed through occlusion. They were also more likely to show misalignments immediately after the target moved from a near to a far position in comparison to far-to-near target movement. DISCUSSION. The data suggest that the prevalence of misalignments in infants of 2 to 3 months of age is decreased by the addition of retinal disparity cues to the stimulus. In addition, target movement away from the infant increases the prevalence of misalignments. These data are compatible with the notion that misalignment are caused by poor sensitivity to targets moving away from the infant and support the theory that some forms of strabismus could be related to failure in a system that is sensitive to the direction of motion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: In a previous study, we demonstrated that children with early onset myopia had greater instability of accommodation than a group of emmetropic children. Since that study was correlational, we were unable to determine the causal relationship between this and myopic progression. To address this, we examined the children two years later. We predicted that if accommodative instability was causing the myopic progression, instability at Visit 1 should predict the refractive error at Visit 2. Additionally, instability at Visit 1 should predict myopic progression. Methods: Thirteen myopic and 16 emmetropic children were included in the analysis. Dynamic measures of accommodation were made using eccentric photorefraction (PowerRefractor) while children viewed targets set at three distances (accommodative demands), namely, 0.25 metres (4.00 D demand), 0.5 metres (2.00 D demand) and 4.00 metres (0.25 D demand). Results: Both refractive error and accommodative instability at Visit 1 were highly correlated with the same measures at Visit 2. Children with myopia showed greater instability of accommodation (0.38 D) than children with emmetropia (0.26 D) at the 4.00 D target on Visit 1 and this instability of accommodation weakly predicted myopic progression. Conclusions: The results presented in the present study suggest that instability of accommodation accompanies myopic progression, although a casual relationship cannot be established.