Resumo:
In this work, IR thermography is used as a non-destructive tool for impact damage characterisation on thermoplastic E-glass/polypropylene composites for automotive applications. The aim of this experimentation was to compare impact resistance and to characterise damage patterns of different laminates, in order to provide indications for their use in components. Two E-glass/polypropylene composites, commingled ®Twintex (with three different weave structures: directional, balanced and 3-D) and random reinforced GMT, were in particular characterised. Directional and balanced Twintex were also coupled in a number of hybrid configurations with GMT to evaluate the possible use of GMT/Twintex hybrids in high-energy absorption components. The laminates were impacted using a falling weight tower, with impact energies ranging from 15 J to penetration. Using IR thermography during cooling down following a long pulse (3 s), impact damaged areas were characterised and the influence of weave structure on damage patterns was studied. IR thermography offered good accuracy for laminates with thickness not exceeding 3.5 mm: this appears to be a limit for the direct use of this method on components, where more refined signal treatment would probably be needed for impact damage characterisation.
Resumo:
Around 40% of total energy consumption in the UK is consumed by creating comfortable indoor environment for occupants. Occupants’ behaviour in terms of achieving thermal comfort could have a significant impact on a building’s energy consumption. Therefore, understanding the interactions of occupants with their buildings would be essential to provide a thermal comfort environment that is less reliance on energy-intensive heating, ventilation and air-conditioning systems, to meet energysaving and carbon emission targets. This paper presents the findings of a year-long field study conducted in non-air-conditioned office buildings in the UK. Occupants’ adaptive responses in terms of technological and personal dimensions are dynamic processes which could vary with both indoor and outdoor thermal conditions. The adaptive behaviours of occupants in the surveyed building show substantial seasonal and daily variations. Our study shows that non-physical factors such as habit could influence the adaptive responses of occupants. However, occupants sometimes displayed inappropriate adaptive behaviour, which could lead to a misuse of energy. This paper attempts to illustrate how occupants would adapt and interact with their built environment and consequently contribute to development of a guide for future design/refurbishment of buildings and to develop energy management systems for a comfortable built environment.
Resumo:
Differential thermal expansion over the range 90-210 K has been applied successfully to determine the crystal structure of chlorothiazide from synchrotron powder diffraction data using direct methods. Key to the success of the approach is the use of a multi-data-set Pawley refinement to extract a set of reflection intensities that is more 'single-crystal-like' than those extracted from a single data set. The improvement in reflection intensity estimates is quantified by comparison with reference single-crystal intensities. (C) 2008 International Union of Crystallography Printed in Singapore - all rights reserved
Resumo:
A year-long field study of the thermal environment in university classrooms was conducted from March 2005 to May 2006 in Chongqing, China. This paper presents the occupants’ thermal sensation votes and discusses the occupants’ adaptive response and perception of the thermal environment in a naturally conditioned space. Comparisons between the Actual Mean Vote (AMV) and Predicted Mean Vote (PMV) have been made as well as between the Actual Percentage of Dissatisfied (APD) and Predicted Percentage of Dissatisfied (PPD). The adaptive thermal comfort zone for the naturally conditioned space for Chongqing, which has hot summer and cold winter climatic characteristics, has been proposed based on the field study results. The Chongqing adaptive comfort range is broader than that of the ASHRAE Standard 55-2004 in general, but in the extreme cold and hot months, it is narrower. The thermal conditions in classrooms in Chongqing in summer and winter are severe. Behavioural adaptation such as changing clothing, adjusting indoor air velocity, taking hot/cold drinks, etc., as well as psychological adaptation, has played a role in adapting to the thermal environment.
Resumo:
A physiological experiment was carried out in a naturally ventilated, non-HVAC indoor environment of a spacious experimental room. More than 300 healthy university students volunteered for this study. The purpose of the study was to investigate the human physiological indicators which could be used to characterise the indoor operative temperature changes in a building and their impact on human thermal comfort based on the different climatic characteristics people would experience in Chongqing, China. The study found that sensory nerve conduction velocity (SCV) could objectively provide a good indicator for assessment of the human response to changes in indoor operative temperatures in a naturally ventilated situation. The results showed that with the changes in the indoor operative temperatures, the changing trend in the nerve conduction velocity was basically the same as that of the skin temperature at the sensory nerve measuring segment (Tskin(scv)). There was good coherent consistency among the factors: indoor operative temperature, SCV and Tskin(scv) in a certain indoor operative temperature range. Through self-adaptation and self-feedback regulation, the human physiological indicators would produce certain adaptive changes to deal with the changes in indoor operative temperature. The findings of this study should provide the baseline data to inform guidelines for the development of thermal environment-related standards that could contribute to efficient use of energy in buildings in China.
Resumo:
This paper presents results for thermal comfort assessment in non-uniform thermal environments. Three types of displacement ventilation (DV) units that created stratified condition in an environmental test chamber have been selected to carry out the thermal comfort assessment: a flat diffuser (DV1), semi-circular diffuser (DV2), and floor swirl diffuser (DV3). The CBE (Center for the Built Environment at Berkeley) comfort model was implemented in this study to assess the occupant’s thermal comfort for the three DV types. The CBE model predicted the occupant’s mean skin as well as local skin temperatures very well when compared with measurements found in the literature, while it underestimated the occupant’s core temperature. The predicted occupant’s thermal sensation and thermal comfort for the case of (DV2) were the best. Therefore, the semi-circular diffuser (DV2) provided better thermal comfort for the occupant in comparison with the other two DV types.
Resumo:
Three-dimensional computational simulations are performed to examine indoor environment and micro-environment around human bodies in an office in terms of thermal environment and air quality. In this study, personal displacement ventilation (PDV), including two cases with all seats taken and two middle seats taken, is compared with overall displacement ventilation (ODV) of all seats taken under the condition that supply temperature is 24℃ and air change rate is 60 l/s per workstation. When using PDV, temperature stratification, the characteristic of displacement ventilation, is obviously observed at the position of occupant’s head and clearer in the case with all seats taken. Verticalertical ertical temperature temperature temperature temperature temperature differences below height of the head areare under under under 2℃ in two cases in two cases in two cases in two cases in two cases in two cases in two cases in two cases with all seats taken,and the temperature with PDV is higher than that with ODV. Verticalertical ertical temperature temperature temperature temperature temperature temperature difference is under 3 under 3under 3 under 3℃ in the case in the case in the case in the case in the case in the case in the case with two middle seats taken. CO2 concentration is lower th is lower th is lower this lower this lower than 2 g/man 2 g/m an 2 g/man 2 g/man 2 g/man 2 g/m 3 in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. The results indicate that PDV can be used in the room with big change of occupants’ number to satisfy the need of thermal comfort and air quality. When not all seats are taken, designers should increase supply air requirement or reduce its temperature for thermal comfort. INDEX TERMS
Resumo:
Designing for indoor thermal environmental conditions is one of the key elements in the energy efficient building design process. This paper introduces a development of the Chinese national Evaluation Standard for indoor thermal environments (Evaluation Standard). International standards including the ASHRAE55, ISO7730, DIN EN, and CIBSE Guide-A have been reviewed and referenced for the development of the Evaluation Standard. In addition, over 28,000 subjects participated in the field study from different climate zones in China and over 500 subjects have been involved in laboratory studies. The research findings reveal that there is a need to update the Chinese thermal comfort standard based on local climates and people's habitats. This paper introduces in detail the requirements for the thermal environment for heated and cooled buildings and free-running buildings in China.
Resumo:
Buildings consume a large amount of energy, in both their use and production. Retrofitting aims to achieve a reduction in this energy consumption. However, there are concerns that retrofitting can cause negative impacts on the internal environment including poor thermal comfort and health issues. This research investigates the impact of retrofitting the façade of existing traditional buildings and the resulting impact on the indoor environment and occupant thermal comfort. A Case building located at the University of Reading has been monitored experimentally and modelled using IES software with monitored values as input conditions for the model. The proposed façade related retrofit options have been simulated and provide information on their effect on the indoor environment. The findings show a positive impact on the internal environment. The data shows a 16.2% improvement in thermal comfort after retrofit is simulated. This also achieved a 21.6% reduction in energy consumption from the existing building.
Resumo:
The toughness of a polymer glass is determined by the interplay of yielding, strain softening, and strain hardening. Molecular-dynamics simulations of a typical polymer glass, atactic polystyrene, under the influence of active deformation have been carried out to enlighten these processes. It is observed that the dominant interaction for the yield peak is of interchain nature and for the strain hardening of intrachain nature. A connection is made with the microscopic cage-to-cage motion. It is found that the deformation does not lead to complete erasure of the thermal history but that differences persist at large length scales. Also we find that the strain-hardening modulus increases with increasing external pressure. This new observation cannot be explained by current theories such as the one based on the entanglement picture and the inclusion of this effect will lead to an improvement in constitutive modeling.
Resumo:
Multilayered hydrogel coatings can be developed on the surface of glass slides via layer-by-layer deposition of hydrogen-bonded interpolymer complexes formed by poly(acrylic acid) and methylcellulose. Chemical modification of the glass surface with (3-aminopropyl)triethoxysilane with subsequent layer-by-layer deposition and cross-linking of interpolymer complexes by thermal treatment allows fabrication of ultrathin hydrogel coatings, not detachable from the substrate. The thickness of these coatings is directly related to the number of deposition cycles and cross-linking conditions. An unusual dependence of the hydrogel swelling properties on the sample thickness is observed and can be interpreted by gradual transitions between two- and three-dimensional networks. The hydrogels exhibit pH-responsive swelling behaviour, achieving higher swelling degrees at pH > 6.0. These coatings can be used as model substrates to study the adhesive properties of pharmaceutical tablets and can potentially mimic the total work of adhesion observed for the detachment of mucoadhesives from porcine buccal mucosa but fail to exhibit identical detachment profiles.