7 resultados para Open Building
em CentAUR: Central Archive University of Reading - UK
Resumo:
There is a clear need for financial protection in the construction industry, both to guarantee satisfactory completion of construction projects and to guard against non-payment. However, the cost of financial protection is often felt to be disproportionately high, with unnecessary overlap between different measures. The Reading Construction Forum has commissioned and steered research which is published in this report in an effort to bring the problem out into the open and to clarify the various options open to the various parties and stakeholders in the construction process. "Financial Protection in the UK Building Industry" is the first definitive report on the subject, offering an accurate and simple guide that all levels within the construction industry can understand. This accessible new guide considers the problem of financial protection and clearly lays out the alternative solutions.It looks by turn at the client, the main contractor, and the sub-contractor, discussing which financial protection options are available to each of them, and considers the pros and cons of each option. The cost of each type of financial protection is weighed against the amount of protection provided and the risks involved. The book concludes with guidance for consultants, emphasising relevant points to consider when advising clients and contractors about which type of financial protection to choose. "Financial Protection in the UK Building Industry" was researched by a literature search, collection of statistical data, and financial data, as well as discussions with clients, contractors, sub-contractors and consultants. This investigation has shown that the direct costs of implementing financial protection measures are marginal, and that wider adoption of payment protection would create a more equitable situation between contracting parties.This guide will enable anyone in the construction industry to consider all the options, and determine what is the best solution for them. "Reading Construction Forum Financial Protection for the UK Building Industry" was complied by the University of Reading, funded by the Reading Construction Forum. The Forum has recently commissioned and steered a number of high-profile reports covering important aspects of the construction industry. Members of the Forum include major companies which are concerned with achieving high quality in the design, construction and use of commercial, retail and industrial buildings. All are committed to change and innovation in the British and European construction industries.
Resumo:
Under low latitude conditions, minimization of solar radiation within the urban environment may often be a desirable criterion in urban design. The dominance of the direct component of the global solar irradiance under clear high sun conditions requires that the street solar access must be small. It is well known that the size and proportion of open spaces has a great influence on the urban microclimate This paper is directed towards finding the interaction between urban canyon geometry and incident solar radiation. The effect of building height and street width on the shading of the street surfaces and ground for different orientations have been examined and evaluated. It is aimed to explore the extent to which these parameters affect the temperature in the street. This work is based on air and surface temperature measurements taken in different urban street canyons in EL-Oued City (hot and and climate), Algeria. In general, the results show that there are less air temperature variations compared to the surface temperature which really depends on the street geometry and sky view factor. In other words, there is a big correlation between the street geometry, sky view factor and surface temperatures.
Resumo:
This paper discusses the implications of the shifting cultural significance of public open space in urban areas. In particular, it focuses on the increasing dysfunction between people's expectations of that space and its actual provision and management. In doing so, the paper applies Lefebvre's ideas of spatiality to the evident paradigm shift from 'public' to 'private' culture, with its associated commodification of previously public space. While developing the construct of paradigm shift, the paper recognises that the former political notions inherent in the provision of public space remain in evidence. So whereas public parks were formerly seen as spaces of confrontation between the 'rationality' of public order as the 'irrationality' of individual leisure pursuits, they are now increasingly seen, particularly 'out of hours', as the domain of the dispossessed, to be defined and policed as 'dangerous'. Where once people were welcomed into public open spaces as a means of 'educating' them in good, acceptable, leisure practices, therefore, they are now increasingly excluded, but for the same ostensible reasons. Building on survey work undertaken in Reading, Berkshire, the paper illustrates how communities can become separated from 'their' space, leaving them with the overriding impression that they have been 'short-changed' in terms of both the provision and the management of urban open space. Rather than the intimacy of local space for local people, therefore, the paper argues that parks have become externalised places, increasingly responding to commercial definitions of culture and what is 'public'. Central urban open spaces are therefore increasingly becoming sites of stratification, signification of a consumer-constructed citizenship and valorisation of public life as a legitimate element of the market surface of town and city centres.
Resumo:
An open-framework indium selenide, [C7H10N][In9Se14], has been prepared under solvothermal conditions in the presence of 3,5-dimethylpyridine, and characterized by single crystal diffraction, thermogravimetry, elemental analysis, FTIR spectroscopy and UV-Vis diffuse reflectance. The crystal structure of [C7H10N][In9Se14] contains an unusual building unit, in which corner-linked and edge-linked InSe45- tetrahedra coexist. The presence of one-dimensional circular channels, of ca. 6 Å diameter, results in approximately 25% of solvent accessible void space.
Resumo:
Semi-open street roofs protect pedestrians from intense sunshine and rains. Their effects on natural ventilation of urban canopy layers (UCL) are less understood. This paper investigates two idealized urban models consisting of 4(2×2) or 16(4×4) buildings under a neutral atmospheric condition with parallel (0°) or non-parallel (15°,30°,45°) approaching wind. The aspect ratio (building height (H) / street width (W)) is 1 and building width is B=3H. Computational fluid dynamic (CFD) simulations were first validated by experimental data, confirming that standard k-ε model predicted airflow velocity better than RNG k-ε model, realizable k–ε model and Reynolds stress model. Three ventilation indices were numerically analyzed for ventilation assessment, including flow rates across street roofs and openings to show the mechanisms of air exchange, age of air to display how long external air reaches a place after entering UCL, and purging flow rate to quantify the net UCL ventilation capacity induced by mean flows and turbulence. Five semi-open roof types are studied: Walls being hung above street roofs (coverage ratio λa=100%) at z=1.5H, 1.2H, 1.1H ('Hung1.5H', 'Hung1.2H', 'Hung1.1H' types); Walls partly covering street roofs (λa=80%) at z=H ('Partly-covered' type); Walls fully covering street roofs (λa=100%) at z=H ('Fully-covered' type).They basically obtain worse UCL ventilation than open street roof type due to the decreased roof ventilation. 'Hung1.1H', 'Hung1.2H', 'Hung1.5H' types are better designs than 'Fully-covered' and 'Partly-covered' types. Greater urban size contains larger UCL volume and requires longer time to ventilate. The methodologies and ventilation indices are confirmed effective to quantify UCL ventilation.
Resumo:
The University of Reading’s first Massive Open Online Course (MOOC) “Begin Programming: Build your first mobile game” (#FLMobiGame) was offered in Autumn 2013 on the FutureLearn platform. This course used a simple Android game framework to present basic programming concepts to complete beginners. The course attracted wide interest from all age groups. The course presented opportunities and challenges to both participants and educators. While some participants had difficulties accessing content some others had trouble grasping the concepts and applying them in a real program. Managing forums was cumbersome with the limited facilities supported by the Beta-platform. A healthy community was formed around the course with the support of social media. The case study reported here is part of an ongoing research programme exploring participants’ MOOC engagement and experience using a grounded, ethnographical approach.
Resumo:
Spatial and temporal fluctuations in the concentration field from an ensemble of continuous point-source releases in a regular building array are analyzed from data generated by direct numerical simulations. The release is of a passive scalar under conditions of neutral stability. Results are related to the underlying flow structure by contrasting data for an imposed wind direction of 0 deg and 45 deg relative to the buildings. Furthermore, the effects of distance from the source and vicinity to the plume centreline on the spatial and temporal variability are documented. The general picture that emerges is that this particular geometry splits the flow domain into segments (e.g. “streets” and “intersections”) in each of which the air is, to a first approximation, well mixed. Notable exceptions to this general rule include regions close to the source, near the plume edge, and in unobstructed channels when the flow is aligned. In the oblique (45 deg) case the strongly three-dimensional nature of the flow enhances mixing of a scalar within the canopy leading to reduced temporal and spatial concentration fluctuations within the plume core. These fluctuations are in general larger for the parallel flow (0 deg) case, especially so in the long unobstructed channels. Due to the more complex flow structure in the canyon-type streets behind buildings, fluctuations are lower than in the open channels, though still substantially larger than for oblique flow. These results are relevant to the formulation of simple models for dispersion in urban areas and to the quantification of the uncertainties in their predictions.