4 resultados para Microchannels
em CentAUR: Central Archive University of Reading - UK
Resumo:
A pharmacokinetic hypothesis of stratum corneum with two parallel pathways, lipophilic and porous hydrophilic, is not well documented yet. Still questionable is the localization of the pores, and the present experiments were designed to elucidate the contribution of extracellular lipids and intracellular keratin to the structure of this pathway. Percutaneous penetration of baclofen, a model zwitterion, was studied in vitro using human cadaver skin. Aqueous or ethanolic saturated solutions of the drug (Cs = 4.6 and 0.4 mg/ mL, respectively) were applied on the skin that was pretreated with: methanol/chloroform (Me/Ch) or acetone-chloroform (Ac/Ch) (1:1) mixtures, or with these solvents followed by 0.2% solution of sodium lauryl sulfate (SLS). As controls, baclofen penetration through the intact full-thickness skin was determined, and the fluxes were 0.18 ±0.08 and 0.14 ±0.07 µg/cm2/h for aqueous and ethanolic solutions, respectively. When Me/Ch was used for 1 h, an expected increase of the penetration was observed, but the lag time, Tlag, was still nearly 20 h. When the less polar mixture, Ac/Ch, was used, no flux enhancement was observed, and with ethanol as the vehicle, decreased penetration was even noted. No effect on baclofen penetration was observed when SLS was used for 1 h after delipidization of the skin was done with either the Me/Ch or Ac/Ch mixture. The results suggest that the polar pathway may be located intercellularly and comprises aqueous regions surrounded by polar lipids, which create the walls of such microchannels.
Resumo:
In this paper we present a compliant neural interface designed to record bladder afferent activity. We developed the implant's microfabrication process using multiple layers of silicone rubber and thin metal so that a gold microelectrode array is embedded within four parallel polydimethylsiloxane (PDMS) microchannels (5 mm long, 100 μm wide, 100 μm deep). Electrode impedance at 1 kHz was optimized using a reactive ion etching (RIE) step, which increased the porosity of the electrode surface. The electrodes did not deteriorate after a 3 month immersion in phosphate buffered saline (PBS) at 37 °C. Due to the unique microscopic topography of the metal film on PDMS, the electrodes are extremely compliant and can withstand handling during implantation (twisting and bending) without electrical failure. The device was transplanted acutely to anaesthetized rats, and strands of the dorsal branch of roots L6 and S1 were surgically teased and inserted in three microchannels under saline immersion to allow for simultaneous in vivo recordings in an acute setting. We utilized a tripole electrode configuration to maintain background noise low and improve the signal to noise ratio. The device could distinguish two types of afferent nerve activity related to increasing bladder filling and contraction. To our knowledge, this is the first report of multichannel recordings of bladder afferent activity.
Resumo:
By placing axons into polymeric micro-channels hosting embedded electrodes the extracellular amplitude of action potentials is greatly increased, allowing for robust recording and noise suppression. We are developing such an electrode interface to record electrical activity from bladder afferents to restore bladder control in patients suffering from spinal cord injury. Here we describe our microchannel electrode interface in terms of design, microfabrication and electrode characteristics and report on in vivo bladder function after implantation of teased dorsal rootlets within microchannels.
Resumo:
We have fabricated a compliant neural interface to record afferent nerve activity. Stretchable gold electrodes were evaporated on a polydimethylsiloxane (PDMS) substrate and were encapsulated using photo-patternable PDMS. The built-in microstructure of the gold film on PDMS allows the electrodes to twist and flex repeatedly, without loss of electrical conductivity. PDMS microchannels (5mm long, 100μm wide, 100μm deep) were then plasma bonded irreversibly on top of the electrode array to define five parallel-conduit implants. The soft gold microelectrodes have a low impedance of ~200kΩ at the 1kHz frequency range. Teased nerves from the L6 dorsal root of an anaesthetized Sprague Dawley rat were threaded through the microchannels. Acute tripolar recordings of cutaneous activity are demonstrated, from multiple nerve rootlets simultaneously. Confinement of the axons within narrow microchannels allows for reliable recordings of low amplitude afferents. This electrode technology promises exciting applications in neuroprosthetic devices including bladder fullness monitors and peripheral nervous system implants.