129 resultados para London Township

em CentAUR: Central Archive University of Reading - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Varied electrostatics experiments followed Benjamin Franklin's pioneering atmospheric investigations. In Knightsbridge, Central London, John Read (1726–1814) installed a sensing rod in the upper part of his house and, using a pith ball electrometer and Franklin chimes, monitored atmospheric electricity from 1789 to 1791. Atmospheric electricity is sensitive to weather and smoke pollution. In calm weather conditions, Read observed two daily electrification maxima in moderate weather, around 9 am and 7 pm. This is likely to represent a double diurnal cycle in urban smoke. Before the motor car and steam railways, one source of the double maximum smoke pattern was the daily routine of fire lighting for domestic heating.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the event of a release of toxic gas in the center of London, the emergency services would need to determine quickly the extent of the area contaminated. The transport of pollutants by turbulent flow within the complex street and building architecture of cities is not straightforward, and we might wonder whether it is at all possible to make a scientifically-reasoned decision. Here we describe recent progress from a major UK project, ‘Dispersion of Air Pollution and its Penetration into the Local Environment’ (DAPPLE, www.dapple.org.uk). In DAPPLE, we focus on the movement of airborne pollutants in cities by developing a greater understanding of atmospheric flow and dispersion within urban street networks. In particular, we carried out full-scale dispersion experiments in central London (UK) during 2003, 2004, 2007, and 2008 to address the extent of the dispersion of tracers following their release at street level. These measurements complemented previous studies because (i) our focus was on dispersion within the first kilometer from the source, when most of the material was expected to remain within the street network rather than being mixed into the boundary layer aloft, (ii) measurements were made under a wide variety of meteorological conditions, and (iii) central London represents a European, rather than North American, city geometry. Interpretation of the results from the full-scale experiments was supported by extensive numerical and wind tunnel modeling, which allowed more detailed analysis under idealized and controlled conditions. In this article, we review the full-scale DAPPLE methodologies and show early results from the analysis of the 2007 field campaign data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Historical smoke concentrations at monthly resolution for the early twentieth century are found for Kew Observatory, London, using the atmospheric electricity proxy technique. Smoke particles modify the electrical properties of urban air: an increase in smoke concentration reduces air's electrical conductivity and increases the Potential Gradient (PG). Calibrated PG data are available from Kew since 1898, and air conductivity was measured routinely between 1909 and 1979 using the technique developed by C.T.R. Wilson. Automated smoke observations at the same site overlap with the atmospheric electrical measurements from 1921, providing an absolute calibration to smoke concentration. This shows that the late nineteenth century winter smoke concentrations at Kew were approximately 100 times greater than contemporary winter smoke concentrations. Following smoke emission regulations reducing the smoke concentration, the electrical parameters of the urban air did not change dramatically. This is suggested to be due to a composition change, with an increase in the abundance of small aerosol compensating for the decrease in smoke. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present results from fast-response wind measurements within and above a busy intersection between two street canyons (Marylebone Road and Gloucester Place) in Westminster, London taken as part of the DAPPLE (Dispersion of Air Pollution and Penetration into the Local Environment; www.dapple.org.uk) 2007 field campaign. The data reported here were collected using ultrasonic anemometers on the roof-top of a building adjacent to the intersection and at two heights on a pair of lamp-posts on opposite sides of the intersection. Site characteristics, data analysis and the variation of intersection flow with the above-roof wind direction (θref) are discussed. Evidence of both flow channelling and recirculation was identified within the canyon, only a few metres from the intersection for along-street and across-street roof-top winds respectively. Results also indicate that for oblique rooftop flows, the intersection flow is a complex combination of bifurcated channelled flows, recirculation and corner vortices. Asymmetries in local building geometry around the intersection and small changes in the background wind direction (changes in 15-min mean θref of 5–10 degrees) were also observed to have profound influences on the behaviour of intersection flow patterns. Consequently, short time-scale variability in the background flow direction can lead to highly scattered in-street mean flow angles masking the true multi-modal features of the flow and thus further complicating modelling challenges.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flow and turbulence above urban terrain is more complex than above rural terrain, due to the different momentum and heat transfer characteristics that are affected by the presence of buildings (e.g. pressure variations around buildings). The applicability of similarity theory (as developed over rural terrain) is tested using observations of flow from a sonic anemometer located at 190.3 m height in London, U.K. using about 6500 h of data. Turbulence statistics—dimensionless wind speed and temperature, standard deviations and correlation coefficients for momentum and heat transfer—were analysed in three ways. First, turbulence statistics were plotted as a function only of a local stability parameter z/Λ (where Λ is the local Obukhov length and z is the height above ground); the σ_i/u_* values (i = u, v, w) for neutral conditions are 2.3, 1.85 and 1.35 respectively, similar to canonical values. Second, analysis of urban mixed-layer formulations during daytime convective conditions over London was undertaken, showing that atmospheric turbulence at high altitude over large cities might not behave dissimilarly from that over rural terrain. Third, correlation coefficients for heat and momentum were analyzed with respect to local stability. The results give confidence in using the framework of local similarity for turbulence measured over London, and perhaps other cities. However, the following caveats for our data are worth noting: (i) the terrain is reasonably flat, (ii) building heights vary little over a large area, and (iii) the sensor height is above the mean roughness sublayer depth.