22 resultados para Liquid chemical waste

em CentAUR: Central Archive University of Reading - UK


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A range of wastes representative of materials currently applied, or with future potential to be applied, to agricultural land in the UK as fertilisers and soil improvers or used as animal bedding in livestock production, were investigated. In addition to full physico-chemical characterization, the materials were analysed for a suite of priority organic contaminants. In general, contaminants were present at relatively low concentrations. For example, polychlorinated dibenzo-p-dioxins/dibenzofurans and polychlorinated biphenyls in biosolids and compost-like-outputs (CLOs) were, in most cases, between 5-50 times lower than proposed and implemented European limit values for biosolids or composts applied to agricultural land. However, the technical basis for these limits may need to be re-evaluated. Polybrominated, and mixed halogenated, dibenzo-p-dioxins/dibenzofurans are not currently considered in risk assessments of dioxins and dioxin-like chemicals, but were detected in the biosolids and compost-like-outputs and their potential contribution to the overall toxic equivalency will be assessed. Other, ‘emerging’ contaminants such as perfluoralkyl compounds (PFCs) and organophosphate flame retardants were detected in several of the waste materials, and their potential significance is discussed. The study is part of a wider research programme that will provide evidence to improve confidence in the use of waste-derived materials in agriculture and establish guidelines to protect the food chain where necessary.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study objectives: There is a possibility that lower air, moisture and light protection could impact on physico-chemical stability of medicines inside multi-compartment compliance aids (MCCAs), although this has not yet been proved. The objectives of the study were to examine the physico-chemical stability of atenolol tablets stored in a compliance aid at room temperature, and at elevated temperature and humidity to simulate practice conditions. Methods: Atenolol 100 mg tablets in 28-chamber, plastic compliance aids with transparent lids were stored for four weeks at room temperature and at 40°C with 75% relative humidity. Tablets were also stored at room temperature in original packaging and Petri dishes. Physical tests were conducted to standards as laid down in the British Pharmacopoeia 2005, and dissolution to those of the United States Pharmacopoeia volume 24. Chemical stability was assessed by a validated high-performance liquid chromatography (HPLC) method. Results: Tablets at room temperature in original packaging, in compliance aids and Petri dishes remained the same in appearance and passed physico-chemical tests. Tablets exposed to 40°C with 75% relative humidity in compliance aids passed tests for uniformity of weight, friability and chemical stability but became pale and moist, softer (82 newtons ± 4; p< 0.0001) than tablets in the original packaging (118 newtons ± 6), more friable (0.14% loss of mass) compared with other tablets (0.005%), and failed the tests for disintegration (>15 minutes) and dissolution (only 15% atenolol released at 30 minutes). Conclusion: Although chemical stability was unaffected, storage in compliance aids at 40°C with 75% relative humidity softened atenolol tablets, prolonged disintegration time and hindered dissolution which could significantly reduce bioavailability. This formulation could be suitable for storage in compliance aids at 25°C, but not in hotter, humid weather.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Matrix-assisted laser desorption/ionization (MALDI) is a key ionization technique in mass spectrometry (MS) for the analysis of labile macromolecules. An important area of study and improvements in relation to MALDI and its application in high-sensitivity MS is that of matrix design and sample preparation. Recently, 4-chloro-alpha-cyanocinnamic acid (ClCCA) has been introduced as a new rationally designed matrix and reported to provide an improved analytical performance as demonstrated by an increase in sequence coverage of protein digests obtained by peptide mass mapping (PMM) (Jaskolla, T. W.; et al. Proc. Natl. Acad. Sci. U.S.A. 2008, 105, 12200-12205). This new matrix shows the potential to be a superior alternative to the commonly used and highly successful alpha-cyano-4-hydroxycinnamic acid (CHCA). We have taken this design one step further by developing and optimizing an ionic liquid matrix (ILM) and liquid support matrix (LSM) using ClCCA as the principle chromophore and MALDI matrix compound. These new liquid matrices possess greater sample homogeneity and a simpler morphology. The data obtained from our studies show improved sequence coverage for BSA digests compared to the traditional CHCA crystalline matrix and for the ClCCA-containing ILM a similar performance to the ClCCA crystalline matrix down to 1 fmol of BSA digest prepared in a single MALDI sample droplet with current sensitivity levels in the attomole range. The LSMs show a high tolerance to contamination such as ammonium bicarbonate, a commonly used buffering agent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A future goal in nuclear fuel reprocessing is the conversion or transmutation of the long-lived radioisotopes of minor actinides, such as americium, into short-lived isotopes by irradiation with neutrons. In order to achieve this transmutation, it is necessary to separate the minor actinides(III), [An(Ill)], from the lanthanides(III), [Ln(Ill)], by solvent extraction (partitioning), because the lanthanides absorb neutrons too effectively and hence limit neutron capture by the transmutable actinides. Partitioning using ligands containing only carbon, hydrogen, nitrogen and oxygen atoms is desirable because they are completely incinerable and thus the final volume of waste is minimised [1]. Nitric acid media will be used in the extraction experiments because it is envisaged that the An(III)/Ln(III) separation process could take place after the PUREX process. There is no doubt that the correct design of a molecule that is capable of acting as a ligand or extraction reagent is required for the effective separation of metal ions such as actinides(III) from lanthanides. Recent attention has been directed towards heterocyclic ligands with for the preferential separation of the minor actinides. Although such molecules have a rich chemistry, this is only now becoming sufficiently well understood in relation to the partitioning process [2]. The molecules shown in Figures I and 2 will be the principal focus of this study. Although the examples chosen here are used rather specific, the guidelines can be extended to other areas such as the separation of precious metals [3].

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Colorectal cancer is one of the most common cancers in Western countries. The World Health Organisation identifies diet as a critical risk factor in the development and progression of this disease and the protective role of high levels of fruit and vegetable consumption. Several studies have shown that apples contain several phenolic compounds that are potent anti-oxidants in humans. However, little is known about other beneficial properties of apple phenolics in cancer. We have used the HT29, HT115 and CaCo-2 cell lines as in vitro models to examine the effect of apple phenolics (0.01–0.1% apple extract) on key stages of colorectal carcinogenesis, namely; DNA damage (Comet assay), colonic barrier function (TER assay), cell cycle progression (DNA content assay) and invasion (Matrigel assay). Our results indicate that a crude extract of apple phenolics can protect against DNA damage, improve barrier function and inhibit invasion (p < 0.05). The anti-invasive effects of the extract were enhanced with twenty-four hour pretreatment of cells (p < 0.05). We have shown that a crude apple extract from waste, rich in phenolic compounds, beneficially influences key stages of carcinogenesis in colon cells in vitro.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A relatively simple, selective, precise and accurate high performance liquid chromatography (HPLC) method based on a reaction of phenylisothiocyanate (PITC) with glucosamine (GL) in alkaline media was developed and validated to determine glucosamine hydrochloride permeating through human skin in vitro. It is usually problematic to develop an accurate assay for chemicals traversing skin because the excellent barrier properties of the tissue ensure that only low amounts of the material pass through the membrane and skin components may leach out of the tissue to interfere with the analysis. In addition, in the case of glucosamine hydrochloride, chemical instability adds further complexity to assay development. The assay, utilising the PITC-GL reaction was refined by optimizing the reaction temperature, reaction time and PITC concentration. The reaction produces a phenylthiocarbarnyl-glucosamine (PTC-GL) adduct which was separated on a reverse-phase (RP) column packed with 5 mu m ODS (C-18) Hypersil particles using a diode array detector (DAD) at 245 nm. The mobile phase was methanol-water-glacial acetic acid (10:89.96:0.04 v/v/v, pH 3.5) delivered to the column at 1 ml min(-1) and the column temperature was maintained at 30 degrees C Using a saturated aqueous solution of glucosamine hydrochloride, in vitro permeation studies were performed at 32 +/- 1 degrees C over 48 h using human epidermal membranes prepared by a heat separation method and mounted in Franz-type diffusion cells with a diffusional area 2.15 +/- 0.1 cm(2). The optimum derivatisation reaction conditions for reaction temperature, reaction time and PITC concentration were found to be 80 degrees C, 30 min and 1 % v/v, respectively. PTC-Gal and GL adducts eluted at 8.9 and 9.7 min, respectively. The detector response was found to be linear in the concentration range 0-1000 mu g ml(-1). The assay was robust with intra- and inter-day precisions (described as a percentage of relative standard deviation, %R.S.D.) < 12. Intra- and inter-day accuracy (as a percentage of the relative error, %RE) was <=-5.60 and <=-8.00, respectively. Using this assay, it was found that GL-HCI permeates through human skin with a flux 1.497 +/- 0.42 mu g cm(-2) h(-1), a permeability coefficient of 5.66 +/- 1.6 x 10(-6) cm h(-1) and with a lag time of 10.9 +/- 4.6 h. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Side chain liquid crystal polymers and elastomers exhibit a rich phase behaviour which arises from the antagonistic influences of the entropically disordered polymer chain configuration and the long range orientational ordering of the mesogenic units. This competition arises since the natural macroscopic phase separation is inhibited by the inherent chemical connectivity of the system. At the heart of this connectivity is the spacer link and we consider here its influence on the phase behaviour. In particular we consider a series of elastomers in which the number of alkyl units in the spacer is systematically varied from 2 to 6. The lengthening of the coupling spacer is accompanied by an alternation of the sign of coupling between the polymer chain and the mesogenic unit. These results demonstrate the dominating influence of the so-called hinge effect in determining the phase behaviour. In addition to the alternation of the sign there is some decrease in the magnitude of the coupling with increasing spacer length.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The polymer backbone of a side-chain liquid crystal polymer exhibits an anisotropic shape due to the coupling of the liquid crystal orientational order of the mesogenic side-chains to the backbone. The magnitude and sign of this coupling may be controlled by chemical design. The introduction of chemical cross-links in to such a system provides both a memory of the anisotropic organisation and a mechanism by which the microscopic anisotropy can be realised at a macroscopic level. We show how this anisotropic network structure yields new phenomena when electric or mechanical fields are applied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A series of chain liquid crystalline copolymers of 4-cyanophenyl 4′-(6-methacryloyloxyhexyloxy)benzoate and 2-methacryloyloxyethyl β-(1-naphthyl)-propenoate were prepared by free radical polymerization. The corresponding polyacrylates could not be prepared in the same way and an alternative method was used for their preparation involving the synthesis of copolymers of the mesogenic monomer and 2-hydroxyethyl acrylate followed by treatment of the resulting polymers with β-(1-naphthyl)propenoyl chloride. The materials are of interest as photoactive liquid crystalline polymers. The effect of introducing a bulky nonmesogenic group into a liquid crystalline copolymer generally lowers the clearing temperature and raises Tg but also gives rise to contrasting phase behaviour in these two series of polymers. Polymethacrylates which show mesomorphism have sharp transitions and continue to exhibit a highly ordered smectic phase over the bulk of their liquid crystal range. Polyacrylates, on the other hand, exhibit a weakening and broadening-out of their thermal transitions consistent with a lowering of order. These results emphasize the effect of the polymer backbone on phase behaviour.