20 resultados para LOW-VOLUME VENTILATION
em CentAUR: Central Archive University of Reading - UK
Resumo:
A simple procedure was developed for packing PicoFrit HPLC columns with chromatographic stationary phase using a reservoir fabricated from standard laboratory HPLC fittings. Packed columns were mounted onto a stainless steel ultra-low volume precolumn filter assembly containing a 0.5-mu m pore size steel frit. This format provided a conduit for the application of the nanospray voltage and protected the column from obstruction by sample material. The system was characterised and operational performance assessed by analysis of a range of peptide standards (n = 9).
Resumo:
Sponge cakes have traditionally been manufactured using multistage mixing methods to enhance potential foam formation by the eggs. Today, use of all-in (single-stage) mixing methods is superseding multistage methods for large-scale batter preparation to reduce costs and production time. In this study, multistage and all-in mixing procedures and three final high-speed mixing times (3, 5, and 15 min) for sponge cake production were tested to optimize a mixing method for pilot-scale research. Mixing for 3 min produced batters with higher relative density values than did longer mixing times. These batters generated well-aerated cakes with high volume and low hardness. In contrast, after 5 and 15 min of high-speed mixing, batters with lower relative density and higher viscosity values were produced. Although higher bubble incorporation and retention were observed, longer mixing times produced better developed gluten networks, which stiffened the batters and inhibited bubble expansion during mixing. As a result, these batters did not expand properly and produced cakes with low volume, dense crumb, and high hardness values. Results for all-in mixing were similar to those for the multistage mixing procedure in terms of the physical properties of batters and cakes (i.e., relative density, elastic moduli, volume, total cell area, hardness, etc.). These results suggest the all-in mixing procedure with a final high-speed mixing time of 3 min is an appropriate mixing method for pilot-scale sponge cake production. The advantages of this method are reduced energy costs and production time.
Resumo:
Thermometer screen properties are poorly characterised at low wind speeds. Temperatures from a large thermometer screen have been compared with those from an automatically shaded open-air fine-wire resistance thermometer. For the majority of 5-minute average measurements obtained between July 2008 and 2009, the screen and fine-wire temperatures agreed closely, with a median difference <0.05◦C. At low wind speeds however, larger temperature differences occurred. When calm (wind speed at 2 metres, u2, ≤ 0.1 m s−1), the difference between screen and open-air temperatures varied from −0.25◦C to +0.87◦C. At night with u2 < 0.5 m s−1, this difference was −0.14◦C to 0.39◦C, and, rarely, up to −0.68◦C to 1.38◦C. At the minimum in the daily temperature cycle, the semi-urban site at Reading had u2 < 1 m s−1 for 52% of the observations 1997–2008, u2 < 0.5 m s−1 for 34% and calm conditions for 20%. Consequently uncertainties in the minimum temperature measurements may arise from poor ventilation, which can propagate through calculations to daily average temperatures. In comparison with the daily minimum temperature, the 0900 UTC synoptic temperature measurement has a much lower abundance (5%) of calm conditions.
Resumo:
Five lactating dairy cows with a permanent cannula in the rumen were given ( kg DM/d) a normal diet (7.8 concentrates, 5.1 hay) or a low-roughage (LR) diet (11.5 concentrates, 1.2 hay) in two meals daily in a two-period crossover design. Milk fat (g/kg) was severely reduced on diet LR. To measure rates of production of individual volatile fatty acids (VFA) in the rumen, 0.5 mCi 1-C-14-acetic acid, 2-C-14-propionic acid, or 1-C-14-n-butyric acid were infused into the rumen for 22 h at intervals of 2 to 6 d; rumen samples were taken over the last 12 h. To measure rumen volume, we infused Cr-EDTA into the rumen continuously, and polyethylene glycol was injected 2 h before the morning feed. Results were very variable, so volumes measured by rumen emptying were used instead. Net production of propionic acid more than doubled on LR, but acetate and butyrate production was only numerically lower. Net production rates pooled across both diets were significantly related to concentrations for each VFA. Molar proportions of net production were only slightly higher than molar proportions of concentrations for acetate and propionate but were lower for butyrate. The net energy value (MJ/d) of production of the three VFA increased from 89.5 on normal to 109.1 on LR, equivalent to 55 and 64% of digestible energy, respectively. Fully interchanging, three-pool models of VFA C fluxes are presented. It is concluded that net production rates of VFA can be measured in non-steady states without the need to measure rumen volumes.
Resumo:
This paper deals with the energy consumption and the evaluation of the performance of air supply systems for a ventilated room involving high- and low-level supplies. The energy performance assessment is based on the airflow rate, which is related to the fan power consumption by achieving the same environmental quality performance for each case. Four different ventilation systems are considered: wall displacement ventilation, confluent jets ventilation, impinging jet ventilation and a high level mixing ventilation system. The ventilation performance of these systems will be examined by means of achieving the same Air Distribution Index (ADI) for different cases. The widely used high-level supplies require much more fan power than those for low-level supplies for achieving the same value of ADI. In addition, the supply velocity, hence the supply dynamic pressure, for a high-level supply is much larger than for low-level supplies. This further increases the power consumption for high-level supply systems. The paper considers these factors and attempts to provide some guidelines on the difference in the energy consumption associated with high and low level air supply systems. This will be useful information for designers and to the authors' knowledge there is a lack of information available in the literature on this area of room air distribution. The energy performance of the above-mentioned ventilation systems has been evaluated on the basis of the fan power consumed which is related to the airflow rate required to provide equivalent indoor environment. The Air Distribution Index (ADI) is used to evaluate the indoor environment produced in the room by the ventilation strategy being used. The results reveal that mixing ventilation requires the highest fan power and the confluent jets ventilation needs the lowest fan power in order to achieve nearly the same value of ADI.
Resumo:
In this paper we are mainly concerned with the development of efficient computer models capable of accurately predicting the propagation of low-to-middle frequency sound in the sea, in axially symmetric (2D) and in fully 3D environments. The major physical features of the problem, i.e. a variable bottom topography, elastic properties of the subbottom structure, volume attenuation and other range inhomogeneities are efficiently treated. The computer models presented are based on normal mode solutions of the Helmholtz equation on the one hand, and on various types of numerical schemes for parabolic approximations of the Helmholtz equation on the other. A new coupled mode code is introduced to model sound propagation in range-dependent ocean environments with variable bottom topography, where the effects of an elastic bottom, of volume attenuation, surface and bottom roughness are taken into account. New computer models based on finite difference and finite element techniques for the numerical solution of parabolic approximations are also presented. They include an efficient modeling of the bottom influence via impedance boundary conditions, they cover wide angle propagation, elastic bottom effects, variable bottom topography and reverberation effects. All the models are validated on several benchmark problems and versus experimental data. Results thus obtained were compared with analogous results from standard codes in the literature.
Resumo:
This paper reports the results of a parametric CFD study on idealized city models to investigate the potential of slope flow in ventilating a city located in a mountainous region when the background synoptic wind is absent. Examples of such a city include Tokyo in Japan, Los Angeles and Phoenix in the US, and Hong Kong. Two types of buoyancy-driven flow are considered, i.e., slope flow from the mountain slope (katabatic wind at night and anabatic wind in the daytime), and wall flow due to heated/cooled urban surfaces. The combined buoyancy-driven flow system can serve the purpose of dispersing the accumulated urban air pollutants when the background wind is weak or absent. The microscopic picture of ventilation performance within the urban structures was evaluated in terms of air change rate (ACH) and age of air. The simulation results reveal that the slope flow plays an important role in ventilating the urban area, especially in calm conditions. Katabatic flow at night is conducive to mitigating the nocturnal urban heat island. In the present parametric study, the mountain slope angle and mountain height are assumed to be constant, and the changing variables are heating/cooling intensity and building height. For a typical mountain of 500 m inclined at an angle of 20° to the horizontal level, the interactive structure is very much dependent on the ratio of heating/cooling intensity as well as building height. When the building is lower than 60 m, the slope wind dominates. When the building is as high as 100 m, the contribution from the urban wall flow cannot be ignored. It is found that katabatic wind can be very beneficial to the thermal environment as well as air quality at the pedestrian level. The air change rate for the pedestrian volume can be as high as 300 ACH.
Resumo:
The aim of the present work is to study the occupants' exposure to fine particulate concentrations in ten nightclubs (NCs) in Athens, Greece. Measurements of PM1 and PM 2.5 were made in the outdoor and indoor environment of each NC. The average indoorPM1 andPM 2.5 concentrations were found to be 181.77 μgm−3 and 454.08 μg m−3 respectively, while the corresponding outdoor values were 11.04 μg m−3 and 32.19 μg m−3. Ventilation and resuspension rates were estimated through consecutive numerical experiments with an indoor air quality model and were found to be remarkably lower than the minimum values recommended by national standards. The relative effects of the ventilation and smoking on the occupants' exposures were examined using multiple regression techniques. Itwas found that given the low ventilation rates, the effect of smoking as well as the occupancy is of the highest importance. Numerical evaluations showed that if the ventilation rates were at the minimum values set by national standards, then the indoor exposures would be reduced at the 70% of the present exposure values.
Resumo:
Direct outdoor air cooling contributes a lot not only to the improvement of the indoor air quality but also to the energy saving. Its full use will reduce the water chiller’s running time especially in some stores where cooling load keeps much higher and longer than that in other buildings. A novel air-conditioning system named Combined Variable Air Volume system (CVAV), combining a normal AHU with a separate outdoor air supply system, was proposed firstly by the authors. The most attractive feature of the system is its full utilization of cooling capacity and freshness of outdoor air in the transition period of the year round. On the basis of the obtain of the dynamic cooling loads of the typical shopping malls in different four cities located in cold climates in China with the aid of DOE-2, the possibility of increasing the amount of outdoor air volume of CVAV system in the transition period instead of operating the water chillers was confirmed. Moreover, a new concept, Direct Outdoor Air Cooling Efficiency (DOACE), was defined as the ratio of cooling capacity of outdoor air to the water chiller, indicating the degree of outdoor air’s utilization. And the DOACE of the CVAV was calculated and compared with that of conventional all-air constant volume air-conditioning systems, the results showed that CVAV bear much more energy saving potential with the 10%~19% higher DOACE and it is a kind of energy efficient systems and can improve the indoor air quality as well.
Resumo:
Semi-open street roofs protect pedestrians from intense sunshine and rains. Their effects on natural ventilation of urban canopy layers (UCL) are less understood. This paper investigates two idealized urban models consisting of 4(2×2) or 16(4×4) buildings under a neutral atmospheric condition with parallel (0°) or non-parallel (15°,30°,45°) approaching wind. The aspect ratio (building height (H) / street width (W)) is 1 and building width is B=3H. Computational fluid dynamic (CFD) simulations were first validated by experimental data, confirming that standard k-ε model predicted airflow velocity better than RNG k-ε model, realizable k–ε model and Reynolds stress model. Three ventilation indices were numerically analyzed for ventilation assessment, including flow rates across street roofs and openings to show the mechanisms of air exchange, age of air to display how long external air reaches a place after entering UCL, and purging flow rate to quantify the net UCL ventilation capacity induced by mean flows and turbulence. Five semi-open roof types are studied: Walls being hung above street roofs (coverage ratio λa=100%) at z=1.5H, 1.2H, 1.1H ('Hung1.5H', 'Hung1.2H', 'Hung1.1H' types); Walls partly covering street roofs (λa=80%) at z=H ('Partly-covered' type); Walls fully covering street roofs (λa=100%) at z=H ('Fully-covered' type).They basically obtain worse UCL ventilation than open street roof type due to the decreased roof ventilation. 'Hung1.1H', 'Hung1.2H', 'Hung1.5H' types are better designs than 'Fully-covered' and 'Partly-covered' types. Greater urban size contains larger UCL volume and requires longer time to ventilate. The methodologies and ventilation indices are confirmed effective to quantify UCL ventilation.